Do you want to publish a course? Click here

Power Systems Transient Stability Indices: Hierarchical Clustering Based Detection of Coherent Groups Of Generators

330   0   0.0 ( 0 )
 Added by Faycal Znidi
 Publication date 2021
and research's language is English




Ask ChatGPT about the research

Coherent groups of generators, i.e., machines with perfectly correlated rotor angles, play an important role in power system stability analysis. This paper introduces a real-time methodology based on hierarchical clustering techniques for discovering the degree of coherency among generators using the synchronization coefficient and the correlation coefficient of the generators rotor angle as the coherency index. Furthermore, the Power Transient Stability Indices (PTSI) were employed to examine the versatile response of the power system. The method uses power systems transients Stability indices, i.e., power Connectivity Factor (CF) index which presents coherently strong generators within the groups, the power Separation Factor (SF) index which unveils to the extent that the generators in different groups tend to swing against the other groups in the event of a disturbance, and the overall system separation index which demonstrates the overall system separation status (CF/SF). The approach is assessed on an IEEE-39 test system with a fully dynamic model. The simulation results presented in this paper demonstrate the efficiency of the proposed approach.

rate research

Read More

In this paper, a wide-area measurement system (WAMS)-based method is proposed to estimate the system state matrix for AC system with integrated voltage source converters (VSCs) and identify the electromechanical modes. The proposed method is purely model-free, requiring no knowledge of accurate network topology and system parameters. Numerical studies in the IEEE 68-bus system with integrated VSCs show that the proposed measurementbased method can accurately identify the electromechanical modes and estimate the damping ratios, the mode shapes, and the participation factors. The work may serve as a basis for developing WAMS-based damping control using VSCs in the future.
Existing coordinated cyber-attack detection methods have low detection accuracy and efficiency and poor generalization ability due to difficulties dealing with unbalanced attack data samples, high data dimensionality, and noisy data sets. This paper proposes a model for cyber and physical data fusion using a data link for detecting attacks on a Cyber-Physical Power System (CPPS). Two-step principal component analysis (PCA) is used for classifying the systems operating status. An adaptive synthetic sampling algorithm is used to reduce the imbalance in the categories samples. The loss function is improved according to the feature intensity difference of the attack event, and an integrated classifier is established using a classification algorithm based on the cost-sensitive gradient boosting decision tree (CS-GBDT). The simulation results show that the proposed method provides higher accuracy, recall, and F-Score than comparable algorithms.
This work presents AEGIS, a novel mixed-signal framework for real-time anomaly detection by examining sensor stream statistics. AEGIS utilizes Kernel Density Estimation (KDE)-based non-parametric density estimation to generate a real-time statistical model of the sensor data stream. The likelihood estimate of the sensor data point can be obtained based on the generated statistical model to detect outliers. We present CMOS Gilbert Gaussian cell-based design to realize Gaussian kernels for KDE. For outlier detection, the decision boundary is defined in terms of kernel standard deviation ($sigma_{Kernel}$) and likelihood threshold ($P_{Thres}$). We adopt a sliding window to update the detection model in real-time. We use time-series dataset provided from Yahoo to benchmark the performance of AEGIS. A f1-score higher than 0.87 is achieved by optimizing parameters such as length of the sliding window and decision thresholds which are programmable in AEGIS. Discussed architecture is designed using 45nm technology node and our approach on average consumes $sim$75 $mu$W power at a sampling rate of 2 MHz while using ten recent inlier samples for density estimation. textcolor{red}{Full-version of this research has been published at IEEE TVLSI}
In this work, we investigate differential chaos shift keying (DCSK), a communication-based waveform, in the context of wireless power transfer (WPT). Particularly, we present a DCSK-based WPT architecture, that employs an analog correlator at the receiver in order to boost the energy harvesting (EH) performance. By taking into account the nonlinearities of the EH process, we derive closed-form analytical expressions for the peak-to-average-power-ratio of the received signal as well as the harvested power. Nontrivial design insights are provided, where it is shown how the parameters of the transmitted waveform affects the EH performance. Furthermore, it is demonstrated that the employment of a correlator at the receiver achieves significant EH gains in DCSK-based WPT systems.
The prediction of electrical power in combined cycle power plants is a key challenge in the electrical power and energy systems field. This power output can vary depending on environmental variables, such as temperature, pressure, and humidity. Thus, the business problem is how to predict the power output as a function of these environmental conditions in order to maximize the profit. The research community has solved this problem by applying machine learning techniques and has managed to reduce the computational and time costs in comparison with the traditional thermodynamical analysis. Until now, this challenge has been tackled from a batch learning perspective in which data is assumed to be at rest, and where models do not continuously integrate new information into already constructed models. We present an approach closer to the Big Data and Internet of Things paradigms in which data is arriving continuously and where models learn incrementally, achieving significant enhancements in terms of data processing (time, memory and computational costs), and obtaining competitive performances. This work compares and examines the hourly electrical power prediction of several streaming regressors, and discusses about the best technique in terms of time processing and performance to be applied on this streaming scenario.
comments
Fetching comments Fetching comments
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا