Do you want to publish a course? Click here

Simulation of an imaging system for internal contamination of lungs using MPA-MURA coded aperture collimator

92   0   0.0 ( 0 )
 Added by Lei Wang
 Publication date 2021
  fields Physics
and research's language is English




Ask ChatGPT about the research

The nuclides inhaled during nuclear accidents usually cause internal contamination of the lungs with low activity. Although a parallel-hole imaging system, which is widely used in medical gamma cameras, has a high resolution and good image quality, owing to its extremely low detection efficiency, it remains difficult to obtain images of inhaled lung contamination. In this study, the Monte Carlo method was used to study the internal lung contamination imaging using the MPA-MURA coded-aperture collimator. The imaging system consisted of an adult male lung model, with a mosaicked, pattern-centered, and anti-symmetric MURA coded-aperture collimator model and a CsI(Tl) detector model. The MLEM decoding algorithm was used to reconstruct the internal contamination image, and the complementary imaging method was used to reduce the number of artifacts. The full width at half maximum of the I-131 point source image reconstructed by the mosaicked, pattern-centered, and anti-symmetric Modified uniformly redundant array (MPA-MURA) coded-aperture imaging reached 2.51 mm, and the signal-to-noise ratio of the simplified respiratory tract source (I-131) image reconstructed through MPA-MURA coded-aperture imaging was 3.98 dB. Although the spatial resolution of MPA-MURA coded aperture imaging is not as good as that of parallel-hole imaging, the detection efficiency of PMA-MURA coded-aperture imaging is two orders of magnitude higher than that of parallel hole collimator imaging. Considering the low activity level of internal lung contamination caused by nuclear accidents, PMA-MURA coded-aperture imaging has significant potential for the development of lung contamination imaging.



rate research

Read More

Precise quantitative delineation of tumor hypoxia is essential in radiation therapy treatment planning to improve the treatment efficacy by targeting hypoxic sub-volumes. We developed a combined imaging system of positron emission tomography (PET) and electron para-magnetic resonance imaging (EPRI) of molecular oxygen to investigate the accuracy of PET imaging in assessing tumor hypoxia. The PET/EPRI combined imaging system aims to use EPRI to precisely measure the oxygen partial pressure in tissues. This will evaluate the validity of PET hypoxic tumor imaging by (near) simultaneously acquired EPRI as ground truth. The combined imaging system was constructed by integrating a small animal PET scanner (inner ring diameter 62 mm and axial field of view 25.6 mm) and an EPRI subsystem (field strength 25 mT and resonant frequency 700 MHz). The compatibility between the PET and EPRI subsystems were tested with both phantom and animal imaging. Hypoxic imaging on a tumor mouse model using $^{18}$F-fluoromisonidazole radio-tracer was conducted with the developed PET/EPRI system. We report the development and initial imaging results obtained from the PET/EPRI combined imaging system.
Computer tomography is one of the most promising new methods to image abnormal tissues inside the human body. Tomography is also used to position the patient accurately before radiation therapy. Hadron therapy for treating cancer has become one of the most advantageous and safe options. In order to fully utilize the advantages of hadron therapy, there is a necessity of performing radiography with hadrons as well. In this paper we present the development of a proton computed tomography system. Our second-generation proton tomography system consists of two upstream and two downstream trackers made up of fibers as active material and a range detector consisting of plastic scintillators. We present details of the detector system, readout electronics, and data acquisition system as well as the commissioning of the entire system. We also present preliminary results from the test beam of the range detector.
133 - M. Lenti , M. Veltri 2011
In this paper we investigate, with a detailed Monte-Carlo simulation based on Geant4, the novel approach [Nucl. Instrum. Methods A588 (2008) 457] to 3D imaging with photon scattering. A monochromatic and well collimated gamma beam is used to illuminate the object to be imaged and the photons Compton scattered are detected by means of a surrounding germanium strip detector. The impact position and the energy of the photons are measured with high precision and the scattering position along the beam axis is calculated. We study as an application of this technique the case of brain imaging but the results can be applied as well to situations where a lighter object, with localized variations of density, is embedded in a denser container. We report here the attainable sensitivity in the detection of density variations as a function of the beam energy, the depth inside the object and size and density of the inclusions. Using a 600 keV gamma beam, for an inclusion with a density increase of 30% with respect to the sorrounding tissue and thickness along the beam of 5 mm, we obtain at midbrain position a resolution of about 2 mm and a contrast of 12%. In addition the simulation indicates that for the same gamma beam energy a complete brain scan would result in an effective dose of about 1 mSv.
The thick GEM (THGEM) [1] is an expanded GEM, economically produced in the PCB industry by simple drilling and etching in G-10 or other insulating materials (fig. 1). Similar to GEM, its operation is based on electron gas avalanche multiplication in sub-mm holes, resulting in very high gain and fast signals. Due to its large hole size, the THGEM is particularly efficient in transporting the electrons into and from the holes, leading to efficient single-electron detection and effective cascaded operation. The THGEM provides true pixilated radiation localization, ns signals, high gain and high rate capability. For a comprehensive summary of the THGEM properties, the reader is referred to [2, 3]. In this article we present a summary of our recent study on THGEM-based imaging, carried out with a 10x10 cm^2 double-THGEM detector.
An extensive comparison of the path uncertainty in single particle tracking systems for ion imaging was carried out based on Monte Carlo simulations. The spatial resolution as function of system parameters such as geometry, detector properties and the energy of proton and helium beams was investigated to serve as a guideline for hardware developments. Primary particle paths were sampled within a water volume and compared to the most likely path estimate obtained from detector measurements, yielding a depth-dependent uncertainty envelope. The maximum uncertainty along this curve was converted to a conservative estimate of the minimal radiographic pixel spacing for a single set of parameter values. Simulations with various parameter settings were analysed to obtain an overview of the reachable pixel spacing as function of system parameters. The results were used to determine intervals of detector material budget and position resolution that yield a pixel spacing small enough for clinical dose calculation. To ensure a pixel spacing below 2 mm, the material budget of a detector should remain below 0.25 % for a position resolution of 200 $mathrm{mu m}$ or below 0.75 % for a resolution of 10 $mathrm{mu m}$. Using protons, a sub-millimetre pixel size could not be achieved for a phantom size of 300 mm or at a large clearance. With helium ions, a sub-millimetre pixel spacing could be achieved even for a large phantom size and clearance, provided the position resolution was less than 100 $mathrm{mu m}$ and material budget was below 0.75 %.
comments
Fetching comments Fetching comments
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا