Do you want to publish a course? Click here

The MKID Exoplanet Camera for Subaru SCExAO

375   0   0.0 ( 0 )
 Added by Sarah Steiger
 Publication date 2020
  fields Physics
and research's language is English




Ask ChatGPT about the research

We present the MKID Exoplanet Camera (MEC), a z through J band (800 - 1400 nm) integral field spectrograph located behind The Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) at the Subaru Telescope on Maunakea that utilizes Microwave Kinetic Inductance Detectors (MKIDs) as the enabling technology for high contrast imaging. MEC is the first permanently deployed near-infrared MKID instrument and is designed to operate both as an IFU, and as a focal plane wavefront sensor in a multi-kHz feedback loop with SCExAO. The read noise free, fast time domain information attainable by MKIDs allows for the direct probing of fast speckle fluctuations that currently limit the performance of most high contrast imaging systems on the ground and will help MEC achieve its ultimate goal of reaching contrasts of $10^{-7}$ at 2$lambda / D$. Here we outline the instrument details of MEC including the hardware, firmware, and data reduction and analysis pipeline. We then discuss MECs current on-sky performance and end with future upgrades and plans.



rate research

Read More

Focal plane wavefront sensing is an elegant solution for wavefront sensing since near-focal images of any source taken by a detector show distortions in the presence of aberrations. Non-Common Path Aberrations and the Low Wind Effect both have the ability to limit the achievable contrast of the finest coronagraphs coupled with the best extreme adaptive optics systems. To correct for these aberrations, the Subaru Coronagraphic Extreme Adaptive Optics instrument hosts many focal plane wavefront sensors using detectors as close to the science detector as possible. We present seven of them and compare their implementation and efficiency on SCExAO. This work will be critical for wavefront sensing on next generation of extremely large telescopes that might present similar limitations.
We present current status of H$alpha$ high-contrast imaging observations with Subaru/SCExAO+VAMPIRES. Our adaptive optics correction at optical wavelengths in combination with (double) spectral differential imaging (SDI) and angular differential imaging (ADI) was capable of detecting a ring-like feature around omi Cet and the H$alpha$ counterpart of jet around RY Tau. We tested the post-processing by changing the order of ADI and SDI and both of the contrast limits achieved $sim10^{-3}-5times10^{-4}$ at $0.3^{primeprime}$, which is comparable to other H$alpha$ high-contrast imaging instruments in the southern hemisphere such as VLT/SPHERE, VLT/MUSE, and MagAO. Subaru/VAMPIRES provides great opportunities for H$alpha$ high-contrast imaging for northern hemisphere targets.
We present the detailed design of the near infrared camera for the SuMIRe (Subaru Measurement of Images and Redshifts) Prime Focus Spectrograph (PFS) being developed for the Subaru Telescope. The PFS spectrograph is designed to collect spectra from 2394 objects simultaneously, covering wavelengths that extend from 380 nm - 1.26 um. The spectrograph is comprised of four identical spectrograph modules, with each module collecting roughly 600 spectra from a robotic fiber positioner at the telescope prime focus. Each spectrograph module will have two visible channels covering wavelength ranges 380 nm - 640 nm and 640 nm - 955 nm, and one near infrared (NIR) channel with a wavelength range 955 nm - 1.26 um. Dispersed light in each channel is imaged by a 300 mm focal length, f/1.07, vacuum Schmidt camera onto a 4k x 4k, 15 um pixel, detector format. For the NIR channel a HgCdTe substrate-removed Teledyne 1.7 um cutoff device is used. In the visible channels, CCDs from Hamamatsu are used. These cameras are large, having a clear aperture of 300 mm at the entrance window, and a mass of ~ 250 kg. Like the two visible channel cameras, the NIR camera contains just four optical elements: a two-element refractive corrector, a Mangin mirror, and a field flattening lens. This simple design produces very good imaging performance considering the wide field and wavelength range, and it does so in large part due to the use of a Mangin mirror (a lens with a reflecting rear surface) for the Schmidt primary. In the case of the NIR camera, the rear reflecting surface is a dichroic, which reflects in-band wavelengths and transmits wavelengths beyond 1.26 um. This, combined with a thermal rejection filter coating on the rear surface of the second corrector element, greatly reduces the out-of-band thermal radiation that reaches the detector.
The Low Wind Effect (LWE) refers to a phenomenon that occurs when the wind speed inside a telescope dome drops below $3$m/s creating a temperature gradient near the telescope spider. This produces phase discontinuities in the pupil plane that are not detected by traditional Adaptive Optics (AO) systems such as the pyramid wavefront sensor or the Shack-Hartmann. Considering the pupil as divided in 4 quadrants by regular spiders, the phase discontinuities correspond to piston, tip and tilt aberrations in each quadrant of the pupil. Uncorrected, it strongly decreases the ability of high contrast imaging instruments utilizing coronagraphy to detect exoplanets at small angular separations. Multiple focal plane wavefront sensors are currently being developed and tested on the Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) instrument at Subaru Telescope: Among them, the Zernike Asymmetric Pupil (ZAP) wavefront sensor already showed on-sky that it could measure the LWE induced aberrations in focal plane images. The Fast and Furious algorithm, using previous deformable mirror commands as temporal phase diversity, showed in simulations its efficiency to improve the wavefront quality in the presence of LWE. A Neural Network algorithm trained with SCExAO telemetry showed promising PSF prediction on-sky. The Linearized Analytic Phase Diversity (LAPD) algorithm is a solution for multi-aperture cophasing and is studied to correct for the LWE aberrations by considering the Subaru Telescope as a 4 sub-aperture instrument. We present the different algorithms, show the latest results and compare their implementation on SCExAO/SUBARU as real-time wavefront sensors for the LWE compensation.
High-contrast imaging techniques now make possible both imaging and spectroscopy of planets around nearby stars. We present the optical design for the Coronagraphic High Angular Resolution Imaging Spectrograph (CHARIS), a lenslet-based, cryogenic integral field spectrograph (IFS) for imaging exoplanets on the Subaru telescope. The IFS will provide spectral information for 138x138 spatial elements over a 2.07 arcsec x 2.07 arcsec field of view (FOV). CHARIS will operate in the near infrared (lambda = 1.15 - 2.5 microns) and will feature two spectral resolution modes of R = 18 (low-res mode) and R = 73 (high-res mode). Taking advantage of the Subaru telescope adaptive optics systems and coronagraphs (AO188 and SCExAO), CHARIS will provide sufficient contrast to obtain spectra of young self-luminous Jupiter-mass exoplanets. CHARIS will undergo CDR in October 2013 and is projected to have first light by the end of 2015. We report here on the current optical design of CHARIS and its unique innovations.
comments
Fetching comments Fetching comments
Sign in to be able to follow your search criteria
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا