Do you want to publish a course? Click here

Homogeneity of neutron transmission imaging over a large sensitive area with a four-channel superconducting detector

60   0   0.0 ( 0 )
 Added by The Dang Vu PhD
 Publication date 2020
  fields Physics
and research's language is English




Ask ChatGPT about the research

We previously proposed a method to detect neutrons by using a current-biased kinetic inductance detector (CB-KID), where neutrons are converted into charged particles using a 10B conversion layer. The charged particles are detected based on local changes in kinetic inductance of X and Y superconducting meanderlines under a modest DC bias current. The system uses a delay-line method to locate the positions of neutron-10B reactions by acquiring the four arrival timestamps of signals that propagate from hot spots created by a passing charged particle to the end electrodes of the meanderlines. Unlike conventional multi-pixel imaging systems, the CB-KID system performs high spatial resolution imaging over a 15 mm x 15 mm sensitive area using only four channel readouts. Given the large sensitive area, it is important to check the spatial homogeneity and linearity of detected neutron positions when imaging with CB-KID. To this end we imaged a pattern of 10B dot absorbers with a precise dot pitch to investigate the spatial homogeneity of the detector. We confirmed the spatial homogeneity of detected dot positions based on the distribution of measured dot pitches across the sensitive area of the detector. We demonstrate potential applications of the system by taking a clear transmission image of tiny metallic screws and nuts and a ladybug. The image was useful for characterizing the ladybug noninvasively. Detection efficiencies were low when the detector was operated at 4 K, so we plan to explore raising the operating temperature towards the critical temperature of the detector as a means to improve counting rates.



rate research

Read More

In this paper, the detection efficiency of a large area neutron sensitive microchannel plate detector has been evaluated. A 6LiF/ZnS detector was employed as the benchmark detector, the TOF spectra of these two detectors were simultaneously measured and the energy spectra were then deduced to calculate the detection efficiency curve of the nMCP detector. Tests show the detection [email protected] meV thermal neutron is 34% for this nMCP detector.
Samples were examined using a superconducting (Nb) neutron imaging system employing a delay-line technique which in previous studies was shown to have high spatial resolution. We found excellent correspondence between neutron transmission and scanning electron microscope (SEM) images of Gd islands with sizes between 15 and 130 micrometer which were thermally-sprayed onto a Si substrate. Neutron transmission images could be used to identify tiny voids in a thermally-sprayed continuous Gd2O3 film on a Si substrate which could not be seen in SEM images. We also found that neutron transmission images revealed pattern formations, mosaic features and co-existing dendritic phases in Woods metal samples with constituent elements Bi, Pb, Sn and Cd. These results demonstrate the merits of the current-biased kinetic inductance detector (CB-KID) system for practical studies in materials science. Moreover, we found that operating the detector at a more optimal temperature (7.9 K) appreciably improved the effective detection efficiency when compared to previous studies conducted at 4 K. This is because the effective size of hot-spots in the superconducting meanderline planes increases with temperature, which makes particle detections more likely.
We show data from a new type of detector that can be used to determine neutron flux, energy distribution, and direction of neutron motion for both fast and thermal neutrons. Many neutron detectors are plagued by large backgrounds from x-rays and gamma rays, and most current neutron detectors lack single-event energy sensitivity or any information on neutron directionality. Even the best detectors are limited by cosmic ray neutron backgrounds. All applications (neutron scattering and radiography, measurements of solar and cosmic ray neutron flux, measurements of neutron interaction cross sections, monitoring of neutrons at nuclear facilities, oil exploration, and searches for fissile weapons of mass destruction) will benefit from the improved neutron detection sensitivity and improved measurements of neutron properties made possible by this detector. The detector is free of backgrounds from x-rays, gamma rays, beta particles, relativistic singely charged particles and cosmic ray neutrons. It is sensitive to thermal neutrons, fission neutrons, and high energy neutrons, with detection features distinctive for each energy range. It is capable of determining the location of a source of fission neutrons based on characteristics of elastic scattering of neutrons by helium nuclei. The detector we have constructed could identify one gram of reactor grade plutonium, one meter away, with less than one minute of observation time.
326 - B.Blau , M.Daum , M.Fertl 2015
There are worldwide efforts to search for physics beyond the Standard Model of particle physics. Precision experiments using ultracold neutrons (UCN) require very high intensities of UCN. Efficient transport of UCN from the production volume to the experiment is therefore of great importance. We have developed a method using prestored UCN in order to quantify UCN transmission in tubular guides. This method simulates the final installation at the Paul Scherrer Institutes UCN source where neutrons are stored in an intermediate storage vessel serving three experimental ports. This method allowed us to qualify UCN guides for their intended use and compare their properties.
TORCH is a time-of-flight detector that is being developed for the Upgrade II of the LHCb experiment, with the aim of providing charged particle identification over the momentum range 2-10 GeV/c. A small-scale TORCH demonstrator with customised readout electronics has been operated successfully in beam tests at the CERN PS. Preliminary results indicate that a single-photon resolution better than 100 ps can be achieved.
comments
Fetching comments Fetching comments
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا