Do you want to publish a course? Click here

Performance and aging studies for the ALICE muon RPCs

106   0   0.0 ( 0 )
 Added by Luca Quaglia
 Publication date 2020
  fields Physics
and research's language is English




Ask ChatGPT about the research

The ALICE muon trigger (MTR) system consists of 72 Resistive Plate Chamber (RPC) detectors arranged in two stations, each composed of two planes with 18 RPCs per plane. The detectors are operated in maxi-avalanche mode using a mixture of 89.7% C$_2$H$_2$F$_4$, 10% i-C$_4$H$_{10}$ and 0.3% SF$_6$. A number of detector performance indicators, such as efficiency and dark current, have been monitored over time throughout the LHC Run2 (2015-18). While the efficiency showed very good stability, a steady increase in the absorbed dark current was observed. Since the end of 2018, the LHC has entered a phase of long shutdown, during which the ALICE experiment will be upgraded to cope with the next phase of data taking, expected in 2021. The MTR is undergoing a major upgrade of the front-end and readout electronics, and will change its functionalities, becoming a Muon Identifier. Only the replacement of the most irradiated RPCs is planned during the upgrade. It is therefore important to perform dedicated studies to gain further insights into the status of the detector. In particular, two RPCs were flushed with pure Ar gas for a prolonged period of time and a plasma was created by fully ionizing the gas. The output gas was analyzed using a Gas Chromatograph combined with a Mass Spectrometer and the possible presence of fluorinated compounds originating from the interaction of the plasma with the inner surfaces of the detector has been assessed using an Ion-Selective Electrode station. This contribution will include a detailed review of the ALICE muon RPC performance at the LHC. The procedure and results of the argon plasma test, described above, are also discussed.



rate research

Read More

81 - F. Berg , L. Desorgher , A. Fuchs 2015
Meson factories are powerful drivers of diverse physics programmes. With beam powers already in the MW-regime attention has to be turned to target and beam line design to further significantly increase surface muon rates available for experiments. For this reason we have explored the possibility of using a neutron spallation target as a source of surface muons by performing detailed Geant4 simulations with pion production cross sections based on a parametrization of existing data. While the spallation target outperforms standard targets in the backward direction by more than a factor 7 it is not more efficient than standard targets viewed under 90{deg}. Not surprisingly, the geometry of the target plays a large role in the generation of surface muons. Through careful optimization, a gain in surface muon rate of between 30 - 60% over the standard box-like target used at the Paul Scherrer Institute could be achieved by employing a rotated slab target. An additional 10% gain could also be possible by utilizing novel target materials such as, e.g., boron carbide.
371 - Antonio Bianchi 2018
Resistive Plate Chambers (RPCs), used for the Muon Spectrometer of the ALICE experiment at CERN LHC, are currently operated in maxi-avalanche mode with a low threshold value and without amplification in the front-end electronics. RPC detectors have shown a good operation stability with the current gas mixture during the entire Run 1 (2010$-$2013) and the ongoing Run 2 (2015$-$2018) at the LHC. The gas mixture is made up of $C_{2}H_{2}F_{4}$, $SF_{6}$ and $iC_{4}H_{10}$. Since the first two gases have high Global Warming Potentials (GWPs), there is the risk that they will be phased out of production in the next years, due to the recent restrictions and regulations of the European Union. Therefore, finding a new eco-friendly gas mixture has become extremely important in order to reduce the emissions of greenhouse gases. In addition, the present $iC_{4}H_{10}$ contribution makes the current gas mixture flammable. Non-flammable components, or at least in non-flammable concentrations, would be advisable to make the operation of detectors simpler and safer. In order to identify a gas mixture suited to cope with the requirements of the ALICE Muon Identifier in the forthcoming High-Luminosity runs, a dedicated experimental set-up has been used to carry out R&D studies on promising gas mixtures with small-size RPCs. Hydrofluoroolefins ($HFOs$) are appropriate candidates to replace the $C_{2}H_{2}F_{4}$ thanks to their very low GWPs, especially $HFO1234ze$ which is not flammable at room temperature. Several tests on $HFO$-based mixtures with addition of various gases are ongoing and encouraging results have already been obtained. Furthermore, the use of $CO_{2}$ as a quencher has been studied as it might represent a valid solution to avoid flammability of the mixture. Finally, medium-term stability of detectors exposed to the cosmic-ray flux will be shown in this paper.
The Muon Ionization Cooling Experiment (MICE) will perform a detailed study of ionization cooling to evaluate the feasibility of the technique. To carry out this program, MICE requires an efficient particle-identification (PID) system to identify muons. The Electron-Muon Ranger (EMR) is a fully-active tracking-calorimeter that forms part of the PID system and tags muons that traverse the cooling channel without decaying. The detector is capable of identifying electrons with an efficiency of 98.6%, providing a purity for the MICE beam that exceeds 99.8%. The EMR also proved to be a powerful tool for the reconstruction of muon momenta in the range 100-280 MeV/$c$.
The performance of the LHCb Muon system and its stability across the full 2010 data taking with LHC running at ps = 7 TeV energy is studied. The optimization of the detector setting and the time calibration performed with the first collisions delivered by LHC is described. Particle rates, measured for the wide range of luminosities and beam operation conditions experienced during the run, are compared with the values expected from simulation. The space and time alignment of the detectors, chamber efficiency, time resolution and cluster size are evaluated. The detector performance is found to be as expected from specifications or better. Notably the overall efficiency is well above the design requirements
We studied the effect of water vapor on the performance of glass Resistive Plate Chambers (RPCs) in the avalanche mode operation. Controlled and calibrated amount of water vapor was added to the RPC gas mixture that has C$_2$H$_2$F$_4$ as the major component. The deterioration in the performance of RPC was observed while operating with wet gas and recovered after switching to standard gas.
comments
Fetching comments Fetching comments
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا