No Arabic abstract
LEO-to-GEO intersatellite links using laser communications bring important benefits to greatly enhance applications such as downloading big amounts of data from LEO satellites by using the GEO satellite as a relay. By using this strategy, the total availability of the LEO satellite increases from less than 1% if the data is downloaded directly to the ground up to about 60% if the data is relayed through GEO. The main drawback of using a GEO relay is that link budget is much more difficult to close due to the much larger distance. However, this can be partially compensated by transmitting at a lower data rate, and still benefiting from the much-higher link availability when compared to LEO-to-ground downlinks, which additionally are more limited by the clouds than the relay option. After carrying out a feasibility study, NICT and the University of Tokyo started preparing a mission to demonstrate the technologies needed to perform these challenging lasercom links. Furthermore, to demonstrate the feasibility of this technique, an extremely-small satellite, i.e. a 6U CubeSat, will be used to achieve data rates as high as 10 Gbit/s between LEO and GEO. Some of the biggest challenges of this mission are the extremely low size, weight and power available in the CubeSat, the accurate pointing precision required for the lasercom link, and the difficulties of closing the link at such a high speed as 10 Gbit/s.
The German-British laser-interferometric gravitational wave detector GEO 600 is in its 13th year of operation since its first lock in 2001. After participating in science runs with other first generation detectors, GEO,600 has continued collecting data as an astrowatch instrument with a duty cycle of 62% during the time when the other detectors have gone offline to undergo substantial upgrades. Less invasive upgrades to demonstrate advanced technologies and improve the GEO 600 sensitivity at high frequencies as part of the GEO-HF program have additionally been carried out in parallel to data taking. We report briefly on the status of GEO 600.
Coronagraphs on future space telescopes will require precise wavefront correction to detect Earth-like exoplanets near their host stars. High-actuator count microelectromechanical system (MEMS) deformable mirrors provide wavefront control with low size, weight, and power. The Deformable Mirror Demonstration Mission (DeMi) payload will demonstrate a 140 actuator MEMS deformable mirror (DM) with SI{5.5}{micrometer} maximum stroke. We present the flight optomechanical design, lab tests of the flight wavefront sensor and wavefront reconstructor, and simulations of closed-loop control of wavefront aberrations. We also present the compact flight DM controller, capable of driving up to 192 actuator channels at 0-250V with 14-bit resolution. Two embedded Raspberry Pi 3 compute modules are used for task management and wavefront reconstruction. The spacecraft is a 6U CubeSat (30 cm x 20 cm x 10 cm) and launch is planned for 2019.
The German-British laser-interferometric gravitational wave detector GEO 600 is in its 14th year of operation since its first lock in 2001. After GEO 600 participated in science runs with other first-generation detectors, a program known as GEO-HF began in 2009. The goal was to improve the detector sensitivity at high frequencies, around 1 kHz and above, with technologically advanced yet minimally invasive upgrades. Simultaneously, the detector would record science quality data in between commissioning activities. As of early 2014, all of the planned upgrades have been carried out and sensitivity improvements of up to a factor of four at the high-frequency end of the observation band have been achieved. Besides science data collection, an experimental program is ongoing with the goal to further improve the sensitivity and evaluate future detector technologies. We summarize the results of the GEO-HF program to date and discuss its successes and challenges.
Liquified noble gases are widely used as a target in direct Dark Matter searches. Signals from scintillation in the liquid, following energy deposition from the recoil nuclei scattered by Dark Matter particles (e.g. WIMPs), should be recorded down to very low energies by photosensors suitably designed to operate at cryogenic temperatures. Liquid Argon based detectors for Dark Matter searches currently implement photo multiplier tubes for signal read-out. In the last few years PMTs with photocathodes operating down to liquid Argon temperatures (87 K) have been specially developed with increasing Quantum Efficiency characteristics. The most recent of these, Hamamatsu Photonics Mod. R11065 with peak QE up to about 35%, has been extensively tested within the R&D program of the WArP Collaboration. During these testes the Hamamatsu PMTs showed superb performance and allowed obtaining a light yield around 7 phel/keVee in a Liquid Argon detector with a photocathodic coverage in the 12% range, sufficient for detection of events down to few keVee of energy deposition. This shows that this new type of PMT is suited for experimental applications, in particular for new direct Dark Matter searches with LAr-based experiments.
Superconducting nanowires are widely used as sensitive single photon detectors with wide spectral coverage and high timing resolution. We describe a demonstration of an array of DC biased superconducting nanowire single photon detectors read out with a microwave multiplexing circuit. In this design, each individual nanowire is part of a resonant LC circuit where the inductance is dominated by the kinetic inductance of the nanowire. The circuit also contains two parallel plate capacitors, one of them is in parallel with the inductor and the other is coupled to a microwave transmission line which carries the signals to a cryogenic low noise amplifier. All of the nanowires are connected via resistors to a single DC bias line that enables the nanowires to be current biased close to their critical current. When a photon hits a nanowire it creates a normal hot spot which produces a voltage pulse across the LC circuit. This pulse rings down at the resonant frequency of the LC circuit over a time period that is fixed by the quality factor. We present measurements of an array of these devices and an evaluation of their performance in terms of frequency and time response.