Do you want to publish a course? Click here

All-Digital Stokes Polarimetry with a Digital Micro-mirror Device

153   0   0.0 ( 0 )
 Added by Angela Dudley
 Publication date 2020
  fields Physics
and research's language is English




Ask ChatGPT about the research

Stokes polarimetry is widely used to extract the polarisation structure of optical fields, typically from six measurements, although it can be extracted from only four. To measure the required intensities, most approaches are based on optical polarisation components. In this work, we present an all-digital approach that enables a rapid measure of all four intensities without any moving components. Our method employs a Polarisation Grating (PG) to simultaneously project the incoming mode into left- and right-circular polarised states, followed by a polarisation-insensitive Digital Micromirror Device (DMD), which digitally introduces a phase retardance for the acquisition of the remaining two polarisation states. We demonstrate how this technique can be applied to measuring the SoP, vectorness and intra-modal phase of optical fields, without any moving components and shows excellent agreement with theory, illustrating fast, real-time polarimetry.



rate research

Read More

284 - Zilong Zhang , Yuan Gao , Xin Wang 2021
A transverse mode selective laser system with gain regulation by a digital micromirror device (DMD) is presented in this letter. The gain regulation in laser medium is adjusted by the switch of the patterns loaded on DMD. Structured pump beam patterns can be obtained after the reflection of the loaded patterns on DMD, and then its defocused into a microchip laser medium by a short focal lens, so that the pump patterns can be transferred to the gain medium to regulate the gain distribution. Corresponding structured laser beams can be generated by this laser system. The laser beam pattern can be regulated easily and quickly, by switching the loaded patterns on DMD. Through this method, we show a simple and flexible laser system to generate on-demand laser beam patterns.
The wavefront measurement of a light beam is a complex task, which often requires a series of spatially resolved intensity measurements. For instance, a detector array may be used to measure the local phase gradient in the transverse plane of the unknown laser beam. In most cases the resolution of the reconstructed wavefront is determined by the resolution of the detector, which in the infrared case is severely limited. Here we employ a Digital Micro-mirror Device (DMD) and a single-pixel detector (i.e. with no spatial resolution) to demonstrate the reconstruction of unknown wavefronts with excellent resolution. Our approach exploits modal decomposition of the incoming field by the DMD, enabling wavefront measurements at 4~kHz of both visible and infrared laser beams.
Light projection displays play an increasingly important role in our modern life. Core projection systems including liquid crystal displays and digital micromirror devices can impose spatial light modulation and actively shape light waves. Recently, the advent of metasurfaces has revolutionized design concepts in nanophotonics, enabling a new family of optical elements with exceptional degrees of freedom. Here, we demonstrate a light projection display technology based on optical metasurfaces, called digital metasurface device (DMSD). Each metasurface pixel in a DMSD is electrically reconfigurable with well-controlled programmability and addressability. The DMSD can not only continuously modulate the intensity of light with high contrast, but also shape the wavefront of light generated by each metasurface pixel and dynamically switch between arbitrary holographic patterns. Our approach will pave an avenue towards the development of customized light projection devices. It will also drive the field of dynamic optical metasurfaces with fresh momentum and inspiring concepts.
We present a new method for real- and complex-valued image reconstruction from two intensity measurements made in the Fourier plane: the Fourier magnitude of the unknown image, and the intensity of the interference pattern arising from superimposition of the original signal with a reference beam. This approach can provide significant advantages in digital holography since it poses less stringent requirements on the reference beam. In particular, it does not require spatial separation between the sought signal and the reference beam. Moreover, the reference beam need not be known precisely, and in fact, may contain severe errors, without leading to a deterioration in the reconstruction quality. Numerical simulations are presented to demonstrate the speed and quality of reconstruction.
We propose and experimentally implement a novel reconfigurable quantum key distribution (QKD) scheme, where the users can switch in real time between conventional QKD and the recently-introduced measurement-device-independent (MDI) QKD. Through this setup, we demonstrate the distribution of quantum keys between three remote parties connected by only two quantum channels, a previously unattempted task. Moreover, as a prominent application, we extract the first quantum digital signature (QDS) rates from a network that uses a measurement-device-independent link. In so doing, we introduce an efficient protocol to distil multiple signatures from the same block of data, thus reducing the statistical fluctuations in the sample and increasing the final QDS rate.
comments
Fetching comments Fetching comments
Sign in to be able to follow your search criteria
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا