Do you want to publish a course? Click here

A project of advanced solid-state neutron polarizer for PF1B instrument at ILL

274   0   0.0 ( 0 )
 Added by Valery Nesvizhevsky
 Publication date 2019
  fields Physics
and research's language is English




Ask ChatGPT about the research

Among Super-Mirror (SM) polarizers, solid-state devices have many advantages. The most relevant is 5-10 times smaller length compared to air-gap polarizers allowing to apply stronger magnetic fields. An important condition for a good SM polarizer is the matching of the substrate SLD (Scattering Length Density) with the SM coating SLD for spin-down neutrons. For traditional Fe/Si SM on Si substrate, this SLD step is positive when a neutron goes from the substrate to the SM, which leads to a significant loss of the polarizer performance at small Q. Instead, we use single-crystal Sapphire/Quartz substrates. The latter show a negative SLD step for spin-down neutrons at the interface with Fe and, therefore, avoid the total reflection regime at small Q. To optimize the polarizer performance, we formulate the concept of Sapphire V-bender, perform ray-tracing simulations of Sapphire V-bender, compare results with those for traditional C-bender on Si, and study experimentally V-bender prototypes with different substrates. Our results show that the choice of substrate material, polarizer geometry and the strength and quality of magnetizing field have dramatic effect. In particular, we compare the performance of polarizer for the applied magnetic field strength of $50 mT$ and $300 mT$. Only the large field strength provides an excellent agreement between the simulated and measured polarization values. For the double-collision configuration, a record polarization $>0.999$ was obtained in the neutron wavelength band of $0.3-1.2 nm$ with only $1%$ decrease at $2 nm$. Without any collimation, the polarization averaged over the full outgoing capture spectrum, $0.997$, was found to be equal to the value obtained previously only using a double polarizer in the crossed (X-SM) geometry. These results are applied in a full-scale polarizer for the PF1B instrument.



rate research

Read More

An ideal solid-state supermirror (SM) neutron polarizer assumes total reflection of neutrons from the SM coating for one spin-component and total absorption for the other, thus providing a perfectly polarized neutron beam at the exit. However, in practice, the substrates neutron-nucleai optical potential does not match perfectly that for spin-down neutrons in the SM. For a positive step in the optical potential (as in a Fe/SiN(x) SM on Si substrate), this mismatch results in spin-independent total reflection for neutrons with small momentum transfer Q, limiting the useful neutron bandwidth in the low-Q region. To overcome this limitation, we propose to replace Si single-crystal substrates by media with higher optical potential than that for spin-down neutrons in the SM ferromagnetic layers. We found single-crystal sapphire and single-crystal quartz as good candidates for solid-state Fe/SiN(x) SM polarizers. To verify this idea, we coated a thick plate of single-crystal sapphire with a m=2.4 Fe/SiN(x) SM. At the T3 instrument at the ILL, we measured the spin-up and spin-down reflectivity curves with 7.5 A neutrons incident from the substrate to the interface between the substrate and the SM coating. The results of this experimental test were in excellent agreement with our expectations: the bandwidth of high polarizing power extended significantly into the low-Q region. This finding, together with the possibility to apply a strong magnetizing field, opens a new road to produce high-efficient solid-state SM polarizers with an extended neutron wavelength bandwidth and near-to-perfect polarizing power.
Lunar laser ranging (LLR) has made major contributions to our understanding of the Moons internal structure and the dynamics of the Earth-Moon system. Because of the recent improvements of the ground-based laser ranging facilities, the present LLR measurement accuracy is limited by the retro-reflectors currently on the lunar surface, which are arrays of small corner-cubes. Because of lunar librations, the surfaces of these arrays do not, in general, point directly at the Earth. This effect results in a spread of arrival times, because each cube that comprises the retroreflector is at a slightly different distance from the Earth, leading to the reduced ranging accuracy. Thus, a single, wide aperture corner-cube could have a clear advantage. In addition, after nearly four decades of successful operations the retro-reflectors arrays currently on the Moon started to show performance degradation; as a result, they yield still useful, but much weaker return signals. Thus, fresh and bright instruments on the lunar surface are needed to continue precision LLR measurements. We have developed a new retro-reflector design to enable advanced LLR operations. It is based on a single, hollow corner cube with a large aperture for which preliminary thermal, mechanical, and optical design and analysis have been performed. The new instrument will be able to reach an Earth-Moon range precision of 1-mm in a single pulse while being subjected to significant thermal variations present on the lunar surface, and will have low mass to allow robotic deployment. Here we report on our design results and instrument development effort.
85 - A.Anghel , T.L.Bailey , G.Bison 2018
Solid deuterium (sD_2) is used as an efficient converter to produce ultracold neutrons (UCN). It is known that the sD_2 must be sufficiently cold, of high purity and mostly in its ortho-state in order to guarantee long lifetimes of UCN in the solid from which they are extracted into vacuum. Also the UCN transparency of the bulk sD_2 material must be high because crystal inhomogeneities limit the mean free path for elastic scattering and reduce the extraction efficiency. Observations at the UCN sources at Paul Scherrer Institute and at Los Alamos National Laboratory consistently show a decrease of the UCN yield with time of operation after initial preparation or later treatment (`conditioning) of the sD_2. We show that, in addition to the quality of the bulk sD_2, the quality of its surface is essential. Our observations and simulations support the view that the surface is deteriorating due to a build-up of D_2 frost-layers under pulsed operation which leads to strong albedo reflections of UCN and subsequent loss. We report results of UCN yield measurements, temperature and pressure behavior of deuterium during source operation and conditioning, and UCN transport simulations. This, together with optical observations of sD_2 frost formation on initially transparent sD_2 in offline studies with pulsed heat input at the North Carolina State University UCN source results in a consistent description of the UCN yield decrease.
The characteristics of the Solid-state Neutron Detector, under development for neutron-scattering measurements at the European Spallation Source, have been simulated with a Geant4-based computer code. The code models the interations of thermal neutrons and ionising radiation in the 6Li-doped scintillating glass of the detector, the production of scintillation light and the transport of optical, scintillation photons through the the scintillator, en route to the photo-cathode of the attached multi-anode photomultiplier. Factors which affect the optical-photon transport, such as surface finish, pixelation of the glass sheet, provision of a front reflector and optical coupling media are compared. Predictions of the detector response are compared with measurements made with neutron and gamma-ray sources, a collimated alpha source and finely collimated beams of 2.5 MeV protons and deuterons.
Accurately measuring the neutron beam polarization of a high flux, large area neutron beam is necessary for many neutron physics experiments. The Fundamental Neutron Physics Beamline (FnPB) at the Spallation Neutron Source (SNS) is a pulsed neutron beam that was polarized with a supermirror polarizer for the NPDGamma experiment. The polarized neutron beam had a flux of $sim10^9$ neutrons per second per cm$^2$ and a cross sectional area of 10$times$12~cm$^2$. The polarization of this neutron beam and the efficiency of a RF neutron spin rotator installed downstream on this beam were measured by neutron transmission through a polarized $^{3}$He neutron spin-filter. The pulsed nature of the SNS enabled us to employ an absolute measurement technique for both quantities which does not depend on accurate knowledge of the phase space of the neutron beam or the $^{3}$He polarization in the spin filter and is therefore of interest for any experiments on slow neutron beams from pulsed neutron sources which require knowledge of the absolute value of the neutron polarization. The polarization and spin-reversal efficiency measured in this work were done for the NPDGamma experiment, which measures the parity violating $gamma$-ray angular distribution asymmetry with respect to the neutron spin direction in the capture of polarized neutrons on protons. The experimental technique, results, systematic effects, and applications to neutron capture targets are discussed.
comments
Fetching comments Fetching comments
Sign in to be able to follow your search criteria
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا