Do you want to publish a course? Click here

Fully-Automated Reduction of Longslit Spectroscopy with the Low Resolution Imaging Spectrometer at Keck Observatory

43   0   0.0 ( 0 )
 Added by Daniel Perley
 Publication date 2019
  fields Physics
and research's language is English




Ask ChatGPT about the research

I present and summarize a software package (LPipe) for completely automated, end-to-end reduction of both bright and faint sources with the Low-Resolution Imaging Spectrometer (LRIS) at Keck Observatory. It supports all gratings, grisms, and dichroics, and also reduces imaging observations, although it does not include multislit or polarimetric reduction capabilities at present. It is suitable for on-the-fly quicklook reductions at the telescope, for large-scale reductions of archival data-sets, and (in many cases) for science-quality post-run reductions of PI data. To demonstrate its capabilities the pipeline is run in fully-automated mode on all LRIS longslit data in the Keck Observatory Archive acquired during the 12-month period between August 2016 and July 2017. The reduced spectra (of 675 single-object targets, totaling ~200 hours of on-source integration time in each camera), and the pipeline itself, are made publicly available to the community.



rate research

Read More

This manuscript describes the design, usage, and data-reduction pipeline developed for the Magellan Inamori Kyocera Echelle (MIKE) spectrometer used with the Magellan telescope at the Las Campanas Observatory. We summarize the basic characteristics of the instrument and discuss observational procedures recommended for calibrating the standard data products. We detail the design and implementation of an IDL based data-reduction pipeline for MIKE data (since generalized to other echelle spectrometers, e.g. Keck/HIRES, VLT/UVES). This includes novel techniques for flat-fielding, wavelength calibration, and the extraction of echelle spectroscopy. Sufficient detail is provided in this manuscript to enable inexperienced observers to understand the strengths and weaknesses of the instrument and software package and an assessment of the related systematics.
Reference star differential imaging (RDI) is a powerful strategy for high contrast imaging. Using example observations taken with the vortex coronagraph mode of Keck/NIRC2 in $L^prime$ band, we demonstrate that RDI provides improved sensitivity to point sources at small angular separations compared to angular differential imaging (ADI). Applying RDI to images of the low-mass stellar companions HIP 79124 C (192 mas separation, $Delta L^prime$=4.01) and HIP 78233 B (141 mas separation, $Delta L^prime$=4.78), the latter a first imaging detection, increases the significance of their detections by up to a factor of 5 with respect to ADI. We compare methods for reference frames selection and find that pre-selection of frames improves detection significance of point sources by up to a factor of 3. In addition, we use observations of the circumstellar disks around MWC 758 and 2MASS J16042165-2130284 to show that RDI allows for accurate mapping of scattered light distributions without self-subtraction artifacts.
A fully autonomous data reduction pipeline has been developed for FRODOSpec, an optical fibre-fed integral field spectrograph currently in use at the Liverpool Telescope. This paper details the process required for the reduction of data taken using an integral field spectrograph and presents an overview of the computational methods implemented to create the pipeline. Analysis of errors and possible future enhancements are also discussed.
We present a new multi-pixel high resolution (R >10^7) spectrometer for the Stratospheric Observatory for Far-Infrared Astronomy (SOFIA). The receiver uses 2 x 7-pixel subarrays in orthogonal polarization, each in an hexagonal array around a central pixel. We present the first results for this new instrument after commissioning campaigns in May and December 2015 and after science observations performed in May 2016 . The receiver is designed to ultimately cover the full 1.8-2.5 THz frequency range but in its first implementation, the observing range was limited to observations of the [CII] line at 1.9 THz in 2015 and extended to 1.83-2.07 THz in 2016. The instrument sensitivities are state-of-the-art and the first scientific observations performed shortly after the commissioning confirm that the time efficiency for large scale imaging is improved by more than an order of magnitude as compared to single pixel receivers. An example of large scale mapping around the Horsehead Nebula is presented here illustrating this improvement. The array has been added to SOFIAs instrument suite already for ongoing observing cycle 4.
119 - K. Tsumura , T. Arai , J. Battle 2011
Absolute spectrophotometric measurements of diffuse radiation at 1 mu m to 2 mu m are crucial to our understanding of the radiative content of the Universe from nucleosynthesis since the epoch of reionization, the composition and structure of the Zodiacal dust cloud in our solar system, and the diffuse galactic light arising from starlight scattered by interstellar dust. The Low Resolution Spectrometer (LRS) on the rocket-borne Cosmic Infrared Background Experiment (CIBER) is a lambda / Delta lambda sim 15-30 absolute spectrophotometer designed to make precision measurements of the absolute near-infrared sky brightness between 0.75 mu m < lambda < 2.1 mu m. This paper presents the optical, mechanical and electronic design of the LRS, as well as the ground testing, characterization and calibration measurements undertaken before flight to verify its performance. The LRS is shown to work to specifications, achieving the necessary optical and sensitivity performance. We describe our understanding and control of sources of systematic error for absolute photometry of the near-infrared extragalactic background light.
comments
Fetching comments Fetching comments
Sign in to be able to follow your search criteria
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا