Do you want to publish a course? Click here

Monitoring Reactor Anti-Neutrinos Using a Plastic Scintillator Detector in a Mobile Laboratory

111   0   0.0 ( 0 )
 Added by Jonathon Coleman
 Publication date 2018
  fields Physics
and research's language is English




Ask ChatGPT about the research

Technology developed for the T2K electromagnetic calorimeter has been adapted to make a small footprint, reliable, segmented detector to characterise anti-neutrinos emitted by nuclear reactors. The device has been developed and demonstrated by the University of Liverpool and underwent field tests at the Wylfa Magnox Reactor on Anglesey, UK. It was situated in a 20,ft ISO shipping container, above ground, roughly 60,m from the 1.5,GWt reactor core. Based on the design of the T2K Near Detector ECal, the device detects anti-neutrinos through the distinctive delayed coincidence signal of inverse $beta$-decay interactions using extruded plastic scintillator and Hamamatsu Multi-Pixel Photon Counters.



rate research

Read More

DANSSino is a simplified pilot version of a solid-state detector of reactor antineutrino (it is being created within the DANSS project and will be installed close to an industrial nuclear power reactor). Numerous tests performed under a 3 GW(th) reactor of the Kalinin NPP at a distance of 11 m from the core demonstrate operability of the chosen design and reveal the main sources of the background. In spite of its small size (20x20x100 ccm), the pilot detector turned out to be quite sensitive to reactor neutrinos, detecting about 70 IBD events per day with the signal-to-background ratio about unity.
131 - S. Oguri , Y. Kuroda , Y. Kato 2014
We developed a segmented reactor-antineutrino detector made of plastic scintillators for application as a tool in nuclear safeguards inspection and performed mostly unmanned field operations at a commercial power plant reactor. At a position outside the reactor building, we measured the difference in reactor antineutrino flux above the ground when the reactor was active and inactive.
Three-dimensional finely grained plastic scintillator detectors bring many advantages in particle detectors, allowing a massive active target which enables a high-precision tracking of interaction products, excellent calorimetry and a sub-nanosecond time resolution. Whilst such detectors can be scaled up to several-tonnes, as required by future neutrino experiments, a relatively long production time, where each single plastic-scintillator element is independently manufactured and machined, together with potential challenges in the assembly, complicates their realisation. In this manuscript we propose a novel design for 3D granular scintillator detectors where O($1~text{cm}^3$) cubes are efficiently glued in a single block of scintillator after being produced via cast polymerization, which can enable rapid and cost-efficient detector construction. This work could become particularly relevant for the detectors of the next-generation long-baseline neutrino-oscillation experiments, such as DUNE, Hyper-Kamiokande and ESSnuB.
We present a characterization of a small (9-liter) and mobile 0.1% 6Li-doped pulse-shape-sensitive plastic scintillator antineutrino detector called SANDD (Segmented AntiNeutrino Directional Detector), constructed for the purpose of near-field reactor monitoring with sensitivity to antineutrino direction. SANDD comprises three different types of module. A detailed Monte Carlo simulation code was developed to match and validate the performance of each of the three modules. The combined model was then used to produce a prediction of the performance of the entire detector. Analysis cuts were established to isolate antineutrino inverse beta decay events while rejecting large fraction of backgrounds. The neutron and positron detection efficiencies are estimated to be 34.8% and 80.2%, respectively, while the coincidence detection efficiency is estimated to be 71.7%, resulting in inverse beta decay detection efficiency of 20.05 +/- 0.2%(stat.) +/- 2.1%(syst.). The predicted directional sensitivity of SANDD produces an uncertainty of 20 degree in the azimuthal direction per 100 detected antineutrino events.
The DANSS project is aimed at creating a relatively compact neutrino spectrometer which does not contain any flammable or other dangerous liquids and may therefore be located very close to the core of an industrial power reactor. As a result, it is expected that high neutrino flux would provide about 15,000 IBD interactions per day in the detector with a sensitive volume of 1 m$^3$. High segmentation of the plastic scintillator will allow to suppress a background down to a 1% level. Numerous tests performed with a simplified pilot prototype DANSSino under a 3 GW$_{th}$ reactor of the Kalinin NPP have demonstrated operability of the chosen design. The DANSS detector surrounded with a composite shield is movable by means of a special lifting gear, varying the distance to the reactor core in a range from 10 m to 12 m. Due to this feature, it could be used not only for the reactor monitoring, but also for fundamental research including short-range neutrino oscillations to the sterile state. Supposing one-year measurement, the sensitivity to the oscillation parameters is expected to reach a level of $sin^2(2theta)$ ~ 0.005 with $Delta m^2 subset (0.02-5.0)$ eV$^2$.
comments
Fetching comments Fetching comments
Sign in to be able to follow your search criteria
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا