In August 2017, Advanced Virgo joined Advanced LIGO for the end of the O2 run, leading to the first gravitational waves detections with the three-detector network. This paper describes the Advanced Virgo calibration and the gravitational wave strain h(t) reconstruction during O2. The methods are the same as the ones developed for the initial Virgo detector and have already been described in previous publications, this paper summarizes the differences and emphasis is put on estimating systematic uncertainties. Thr
The three Advanced Virgo and LIGO gravitational wave detectors participated to the third observing run (O3) between 1 April 2019 15:00 UTC and 27 March 2020 17:00 UTC,leading to weekly detections of gravitational waves. This paper describes the Advanced Virgo detector calibration and the reconstruction of the detector strain $h(t)$ during O3, as well as the estimation of the associated uncertainties. For the first time, the photon calibration technique as been used as reference for Virgo calibration, which allowed to cross-calibrate the strain amplitude of the Virgo and LIGO detectors. The previous reference, so-called free swinging Michelson technique, has still been used but as an independent cross-check. $h(t)$ reconstruction and noise subtraction were processed online, with good enough quality to prevent the need for offline reprocessing, except for the two last weeks of September 2019. The uncertainties for the reconstructed $h(t)$ strain, estimated in this paper, are frequency independent: 5% in amplitude, 35 mrad in phase and 10 $mu$s in timing, with the exception of larger uncertainties around 50 Hz.
Virgo is a kilometer-length interferometer for gravitational waves detection located near Pisa. Its first science run, VSR1, occured from May to October 2007. The aims of the calibration are to measure the detector sensitivity and to reconstruct the time series of the gravitational wave strain h(t). The absolute length calibration is based on an original non-linear reconstruction of the differential arm length variations in free swinging Michelson configurations. It uses the laser wavelength as length standard. This method is used to calibrate the frequency dependent response of the Virgo mirror actuators and derive the detector in-loop response and sensitivity within ~5%. The principle of the strain reconstruction is highlighted and the h(t) systematic errors are estimated. A photon calibrator is used to check the sign of h(t). The reconstructed h(t) during VSR1 is valid from 10 Hz up to 10 kHz with systematic errors estimated to 6% in amplitude. The phase error is estimated to be 70 mrad below 1.9 kHz and 6 micro-seconds above.
The Virgo detector is a kilometer-scale interferometer for gravitational wave detection located near Pisa (Italy). About 13 months of data were accumulated during four science runs (VSR1, VSR2, VSR3 and VSR4) between May 2007 and September 2011, with increasing sensitivity. In this paper, the method used to reconstruct, in the range 10 Hz-10 kHz, the gravitational wave strain time series $h(t)$ from the detector signals is described. The standard consistency checks of the reconstruction are discussed and used to estimate the systematic uncertainties of the $h(t)$ signal as a function of frequency. Finally, an independent setup, the photon calibrator, is described and used to validate the reconstructed $h(t)$ signal and the associated uncertainties. The uncertainties of the $h(t)$ time series are estimated to be 8% in amplitude. The uncertainty of the phase of $h(t)$ is 50 mrad at 10 Hz with a frequency dependence following a delay of 8 $mu$s at high frequency. A bias lower than $4,mathrm{mu s}$ and depending on the sky direction of the GW is also present.
The speed of gravitational waves for a single observation can be measured by the time delay among gravitational-wave detectors with Bayesian inference. Then multiple measurements can be combined to produce a more accurate result. From the near simultaneous detection of gravitational waves and gamma rays originating from GW170817/GRB 170817A, the speed of gravitational wave signal was found to be the same as the the speed of the gamma rays to approximately one part in $10^{15}$. Here we present a different method of measuring the speed of gravitational waves, not based on an associated electromagnetic signal but instead by the measured transit time across a geographically separated network of detectors. While this method is far less precise, it provides an independent measurement of the speed of gravitational waves. For GW170817 a binary neutron star inspiral observed by Advanced LIGO and Advanced Virgo, by fixing sky localization of the source at the electromagnetic counterpart the speed of gravitational waves is constrained to 90% confidence interval (0.97c, 1.02c), where c is the speed of light in a vacuum. By combing seven BBH events and the BNS event from the second observing run of Advanced LIGO and Advanced Virgo, the 90% confidence interval is narrowed down to (0.97c, 1.01c). The accurate measurement of the speed of gravitational waves allows us to test the general theory of relativity. We further interpret these results within the test framework provided by the gravitational Standard-Model Extension (SME). In doing so, we obtain simultaneous constraints on 4 of the 9 nonbirefringent, nondispersive coefficients for Lorentz violation in the gravity sector of the SME and place limits on the anisotropy of the speed of gravity.
The Virgo detector is a kilometer-length interferometer for gravitational wave detection located near Pisa (Italy). During its second science run (VSR2) in 2009, six months of data were accumulated with a sensitivity close to its design. In this paper, the methods used to determine the parameters for sensitivity estimation and gravitational wave reconstruction are described. The main quantities to be calibrated are the frequency response of the mirror actuation and the sensing of the output power. Focus is also put on their absolute timing. The monitoring of the calibration data as well as the parameter estimation with independent techniques are discussed to provide an estimation of the calibration uncertainties. Finally, the estimation of the Virgo sensitivity in the frequency-domain is described and typical sensitivities measured during VSR2 are shown.
Virgo Collaboration: F. Acernese
,T. Adams
,K. Agatsuma
.
(2018)
.
"Calibration of Advanced Virgo and Reconstruction of the Gravitational Wave Signal h(t) during the Observing Run O2"
.
Loic Rolland
هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا