Investigating the Efficiency of the Beijing Faint Object Spectrograph and Camera (BFOSC) of the Xinglong 2.16-m Reflector

125   0   0.0 ( 0 )
 Added by Juanjuan Ren
 Publication date 2018
  fields Physics
and research's language is English




Ask ChatGPT about the research

The Beijing Faint Object Spectrograph and Camera (BFOSC) is one of the most important instruments of the 2.16-m telescope of the Xinglong Observatory. Every year there are ~ 20 SCI-papers published based on the observational data of this telescope. In this work, we have systemically measured the total efficiency of the BFOSC of the 2.16-m reflector, based on the observations of two ESO flux standard stars. We have obtained the total efficiencies of the BFOSC instrument of different grisms with various slit widths in almost all ranges, and analysed the factors which effect the efficiency of telescope and spectrograph. For the astronomical observers, the result will be useful for them to select a suitable slit width, depending on their scientific goals and weather conditions during the observation; For the technicians, the result will help them systemically find out the real efficiency of telescope and spectrograph, and further to improve the total efficiency and observing capacity of the telescope technically.

rate research

Read More

The Xinglong 2.16-m reflector is the first 2-meter class astronomical telescope in China. It was jointly designed and built by the Nanjing Astronomical Instruments Factory (NAIF), Beijing Astronomical Observatory (now National Astronomical Observatories, Chinese Academy of Sciences, NAOC) and Institute of Automation, Chinese Academy of Sciences in 1989. It is Ritchey-Chr{e}tien (R-C) reflector on an English equatorial mount and the effective aperture is 2.16 meters. It had been the largest optical telescope in China for $sim18$ years until the Guoshoujing Telescope (also called Large Sky Area Multi-Object Fiber Spectroscopic Telescope, LAMOST) and the Lijiang 2.4-m telescope were built. At present, there are three main instruments on the Cassegrain focus available: the Beijing Faint Object Spectrograph and Camera (BFOSC) for direct imaging and low resolution ($Rsim500-2000$) spectroscopy, the spectrograph made by Optomechanics Research Inc. (OMR) for low resolution spectroscopy (the spectral resolutions are similar to those of BFOSC) and the fiber-fed High Resolution Spectrograph (HRS, $Rsim30000-65000$). The telescope is widely open to astronomers all over China as well as international astronomical observers. Each year there are more than 40 ongoing observing projects, including 6-8 key projects. Recently, some new techniques and instruments (e.g., astro-frequency comb calibration system, polarimeter and adaptive optics) have been or will be tested on the telescope to extend its observing abilities.
Mt. Abu Faint Object Spectrograph and Camera - Pathfinder (MFOSC-P) is an imager-spectrograph developed for the Physical Research Laboratory (PRL) 1.2m telescope at Gurushikhar, Mt. Abu, India. MFOSC-P is based on a focal reducer concept and provides seeing limited imaging (with a sampling of 3.3 pixels per arc-second) in Bessells B, V, R, I and narrow-band H-$alpha$ filters. The instrument uses three plane reflection gratings, covering the spectral range of 4500-8500$AA$, with three different resolutions of 500, 1000, and 2000 around their central wavelengths. MFOSC-P was conceived as a pathfinder instrument for a next-generation instrument on the PRLs 2.5m telescope which is coming up at Mt. Abu. The instrument was developed during 2015-2019 and successfully commissioned on the PRL 1.2m telescope in February 2019. The designed performance has been verified with laboratory characterization tests and on-sky commissioning observations. Different science programs covering a range of objects are being executed with MFOSC-P since then, e.g., spectroscopy of M-dwarfs, novae $&$ symbiotic systems, and detection of H-$alpha$ emission in star-forming regions. MFOSC-P presents a novel design and cost-effective way to develop a FOSC (Faint Object Spectrograph and Camera) type of instrument on a shorter time-scale of development. The design and development methodology presented here is most suitable in helping the small aperture telescope community develop such a versatile instrument, thereby diversifying the science programs of such observatories.
As deformations of the main reflector of a radio telescope directly affect the observations, the evaluation of the deformation is extremely important. Dynamic characteristics of the main reflector of the Nobeyama 45 m radio telescope, Japan, are measured under two conditions: The first is when the pointing observation is in operation, and the second is when the reflector is stationary and is subjected to wind loads when the observation is out of operation. Dynamic characteristics of the main reflector are measured using piezoelectric accelerometers. When the telescope is in operation, a vibration mode with one nodal line horizontally or vertically on the reflector is induced, depending on whether the reflector is moving in the azimuthal or elevational planes, whereas under windy conditions, vibration modes that have two to four nodal lines are simultaneously induced. The predominant mode is dependent on the direction of wind loads.
We present the detailed design of the near infrared camera for the SuMIRe (Subaru Measurement of Images and Redshifts) Prime Focus Spectrograph (PFS) being developed for the Subaru Telescope. The PFS spectrograph is designed to collect spectra from 2394 objects simultaneously, covering wavelengths that extend from 380 nm - 1.26 um. The spectrograph is comprised of four identical spectrograph modules, with each module collecting roughly 600 spectra from a robotic fiber positioner at the telescope prime focus. Each spectrograph module will have two visible channels covering wavelength ranges 380 nm - 640 nm and 640 nm - 955 nm, and one near infrared (NIR) channel with a wavelength range 955 nm - 1.26 um. Dispersed light in each channel is imaged by a 300 mm focal length, f/1.07, vacuum Schmidt camera onto a 4k x 4k, 15 um pixel, detector format. For the NIR channel a HgCdTe substrate-removed Teledyne 1.7 um cutoff device is used. In the visible channels, CCDs from Hamamatsu are used. These cameras are large, having a clear aperture of 300 mm at the entrance window, and a mass of ~ 250 kg. Like the two visible channel cameras, the NIR camera contains just four optical elements: a two-element refractive corrector, a Mangin mirror, and a field flattening lens. This simple design produces very good imaging performance considering the wide field and wavelength range, and it does so in large part due to the use of a Mangin mirror (a lens with a reflecting rear surface) for the Schmidt primary. In the case of the NIR camera, the rear reflecting surface is a dichroic, which reflects in-band wavelengths and transmits wavelengths beyond 1.26 um. This, combined with a thermal rejection filter coating on the rear surface of the second corrector element, greatly reduces the out-of-band thermal radiation that reaches the detector.
The New IRAM KID Array (NIKA) instrument is a dual-band imaging camera operating with Kinetic Inductance Detectors (KID) cooled at 100 mK. NIKA is designed to observe the sky at wavelengths of 1.25 and 2.14 mm from the IRAM 30 m telescope at Pico Veleta with an estimated resolution of 13,arcsec and 18 arcsec, respectively. This work presents the performance of the NIKA camera prior to its opening to the astrophysical community as an IRAM common-user facility in early 2014. NIKA is a test bench for the final NIKA2 instrument to be installed at the end of 2015. The last NIKA observation campaigns on November 2012 and June 2013 have been used to evaluate this performance and to improve the control of systematic effects. We discuss here the dynamical tuning of the readout electronics to optimize the KID working point with respect to background changes and the new technique of atmospheric absorption correction. These modifications significantly improve the overall linearity, sensitivity, and absolute calibration performance of NIKA. This is proved on observations of point-like sources for which we obtain a best sensitivity (averaged over all valid detectors) of 40 and 14 mJy.s$^{1/2}$ for optimal weather conditions for the 1.25 and 2.14 mm arrays, respectively. NIKA observations of well known extended sources (DR21 complex and the Horsehead nebula) are presented. This performance makes the NIKA camera a competitive astrophysical instrument.