A 3D-printed alkali metal dispenser


Abstract in English

We demonstrate and characterize a source of Li atoms made from direct metal laser sintered titanium. The sources outgassing rate is measured to be $5 ,(2)cdot 10^{-7}$,$rm{Pa}~ rm{L}~ rm{s}^{-1}$ at a temperature $T=330,^circ$C, which optimizes the number of atoms loaded into a magneto-optical trap. The source loads $approx 10^7$ $^7$Li atoms in the trap in $approx 1$,s. The loaded source weighs 700,mg and is suitable for a number of deployable sensors based on cold atoms.

Download