In the framework of the upgrade of the SPARC_LAB facility at INFN-LNF, named EuPRAXIA@SPARC_LAB, a high gradient linac is foreseen. One of the most suitable options is to realize it in X-band. A preliminary design study of both accelerating structures and power distribution system has been performed. It is based on 0.5 m long travelling wave (TW) accelerating structures operating in the 2{pi}/3 mode and fed by klystrons and pulse compressor systems. The main parameters of the structures and linac are presented with the basic RF linac layout.



rate research

Read More

In the framework of the Eupraxia Design Study an advanced accelerator facility EUPRAXIA@SPARC_LAB has been proposed to be realized at Frascati (Italy) Laboratories of INFN. Two advanced acceleration schemes will be applied, namely an ultimate high gradient 1 GeV X-band linac together with a plasma acceleration stage to provide accelerating gradients of the GeV/m order. A FEL scheme is foreseen to produce X-ray beams within 3-10 nm range. A 500-TW Laser system is also foreseen for electron and ion production experiments and a Compton backscattering Interaction is planned together with extraction beamlines at intermediate electron beam energy for neutron beams and THz radiation production. The electron beam dynamics studies in the linac are here presented together with the preliminary machine layout.
At EuPRAXIA@SPARC_LAB, the unique combination of an advanced high-brightness RF injector and a plasma-based accelerator will drive a new multi-disciplinary user-facility. The facility, that is currently under study at INFN-LNF Laboratories (Frascati, Italy) in synergy with the EuPRAXIA collaboration, will operate the plasma-based accelerator in the external injection configuration. Since in this configuration the stability and reproducibility of the acceleration process in the plasma stage is strongly influenced by the RF-generated electron beam, the main challenge for the RF injector design is related to generating and handling high quality electron beams. In the last decades of R&D activity, the crucial role of high-brightness RF photo-injectors in the fields of radiation generation and advanced acceleration schemes has been largely established, making them effective candidates to drive plasma-based accelerators as pilots for user facilities. An RF injector consisting in a high-brightness S-band photo-injector followed by an advanced X-band linac has been proposed for the EuPRAXIA@SPARC_LAB project. The electron beam dynamics in the photo-injector has been explored by means of simulations, resulting in high-brightness, ultra-short bunches with up to 3 kA peak current at the entrance of the advanced X-band linac booster. The EuPRAXIA@SPARC_LAB high-brightness photo-injector is described here together with performance optimisation and sensitivity studies aiming to actual check the robustness and reliability of the desired working point.
On the wake of the results obtained so far at the SPARC_LAB test-facility at the Laboratori Nazionali di Frascati (Italy), we are currently investigating the possibility to design and build a new multi-disciplinary user-facility, equipped with a soft X-ray Free Electron Laser (FEL) driven by a $sim$1 GeV high brightness linac based on plasma accelerator modules. This design study is performed in synergy with the EuPRAXIA design study. In this paper we report about the recent progresses in the on going design study of the new facility.
We are proposing a facility based on high gradient acceleration via x-band RF structures and plasma acceleration. We plan to reach an electron energy of the order of 1 GeV, suitable to drive a Free Electron Laser for applications in the so called water window (2 - 4 nm). A conceptual design of the beamline, from the photon beam from the undulators to the user experimental chamber, mainly focusing on diagnostic, manipulation and transport of the radiation is presented and discussed. We also briefly outline a user end station for coherent imaging, laser ablation and pump-probe experiments.
58 - S. Fukuda , A. Anami , C. Kubota 2000
The construction of the 60-MeV proton linac has started as a low-energy front of the KEK/JAERI Joint Project for a high-intensity proton accelerator facility at KEK. The accelerating frequency is 324 MHz. Five UHF klystrons are used as an rf source; their ratings have a maximum power of 3 MW, a beam pulse width of a 700 micro-sec (an rf pulse width is 650 micro-sec) and a repetition rate of 50 pps. We have manufactured a proto-type rf source (a power-supply system with a modulating-anode pulse modulator and prototype klystrons). In this paper, the specifications and developments of the rf source, including the WR-2300 waveguide system, are summarized. During the manufacturing process, strong oscillations due to back-going electrons from the collector were observed. This phenomenon was analyzed both experimentally and theoretically. We have tested up to an output power of nearly 3 MW, and succeeded to test the DTL hot-model structure.