Do you want to publish a course? Click here

Optical quality assurance of GEM foils

94   0   0.0 ( 0 )
 Added by Erik Br\\\"ucken
 Publication date 2017
  fields Physics
and research's language is English




Ask ChatGPT about the research

An analysis software was developed for the high aspect ratio optical scanning system in the Detec- tor Laboratory of the University of Helsinki and the Helsinki Institute of Physics. The system is used e.g. in the quality assurance of the GEM-TPC detectors being developed for the beam diagnostics system of the SuperFRS at future FAIR facility. The software was tested by analyzing five CERN standard GEM foils scanned with the optical scanning system. The measurement uncertainty of the diameter of the GEM holes and the pitch of the hole pattern was found to be 0.5 {mu}m and 0.3 {mu}m, respectively. The software design and the performance are discussed. The correlation between the GEM hole size distribution and the corresponding gain variation was studied by comparing them against a detailed gain mapping of a foil and a set of six lower precision control measurements. It can be seen that a qualitative estimation of the behavior of the local variation in gain across the GEM foil can be made based on the measured sizes of the outer and inner holes.



rate research

Read More

119 - M. Posik , B. Surrow 2016
Many experiments are currently using or proposing to use large area GEM foils in their detectors, which is creating a need for commercially available GEM foils. Currently CERN is the only main distributor of large GEM foils, however with the growing interest in GEM technology keeping up with the increasing demand for GEMs will be difficult. Thus the commercialization of GEMs up to 50 $times$ 50 cm$^2$ has been established by Tech-Etch Inc. of Plymouth, MA, USA using the single-mask technique. The electrical performance and optical quality of the single-mask GEM foils have been found to be on par with those produced by CERN. The next critical step towards validating the Tech-Etch single-mask GEM foils is to test their performance under physics conditions. These measurements will allow us to quantify and compare the gain and efficiency of the detector to other triple-GEM detectors. This will be done by constructing several single-mask triple-GEM detectors, using foils manufactured by Tech-Etch, which follow the design used by the STAR Forward GEM Tracker (FGT). These detectors will investigate ways in which to further decrease the material budget and increase the efficiency of the detector by incorporating perforated Kapton spacer rings rather than G10 spacing grids to reduce the dead area of the detector. The materials and tooling needed to assemble the triple-GEM detectors have been acquired. The GEM foils have been electrically tested, and a handful have been optically scanned. We found these results to be consistent with GEM foils produced by CERN. With the success of these initial tests, construction of the triple-GEM detectors is now under way.
83 - M. Posik , B. Surrow 2015
Many experiments are currently using or proposing to use large area GEM foils in their detectors, which is creating a need for commercially available GEM foils. Currently CERN is the only main distributor of GEM foils, however with the growing interest in GEM technology keeping up with the increasing demand for GEM foils will be difficult. Thus the commercialization of GEM foils has been established by Tech-Etch Inc. of Plymouth, MA, USA using the single-mask technique, which is capable of producing GEM foils over a meter long. To date Tech-Etch has successfully manufactured 10 $times$ 10 cm$^2$ and 40 $times$ 40 cm$^2$ GEM foils. We will report on the electrical and geometrical properties, along with the inner and outer hole diameter size uniformity of these foils. Furthermore, Tech-Etch has now begun producing even larger GEM foils of 50 $times$ 50 cm$^2$, and are currently looking into how to accommodate GEM foils on the order of one meter long. The Tech-Etch foils were found to have excellent electrical properties. The measured mean optical properties were found to reflect the desired parameters and are consistent with those measured in double-mask GEM foils, as well as single-mask GEM foils produced at CERN. They also show good hole diameter uniformity over the active area.
243 - M. Posik , B. Surrow 2015
With future experiments proposing detectors that utilize very large-area GEM foils, there is a need for commercially available GEM foils. Double-mask etching techniques pose a clear limitation in the maximum size of GEM foils. In contrast, single-mask techniques developed at CERN would allow one to overcome those limitations. However with interest in GEM foils increasing and CERN being the only main distributor, keeping up with the demand for GEM foils will be difficult. Thus the commercialization of GEMs has been established by Tech-Etch of Plymouth, MA, USA using single-mask techniques. We report on the electrical and geometrical properties, along with the inner and outer hole diameter size uniformity of 10 $times$ 10 cm$^2$ and 40$times$40 cm$^2$ GEM foils. The Tech-Etch foils were found to have excellent electrical properties. The measured mean optical properties were found to reflect the desired parameters and are consistent with those measured in double-mask GEM foils, and show good hole diameter uniformity over the active area. These foils are well suited for future applications in nuclear and particle physics where tracking devices are needed.
The Mu2e calorimeter is composed of two disks each containing 1348 pure CsI crystals, each crystal read out by two arrays of 6x6 mm2 monolithic SiPMs. The experimental requirements have been translated in a series of technical specifications for both crystals and SiPMs. Quality assurance tests, on first crystal and then SiPM production batches, confirm the performances of preproduction samples previously assembled in a calorimeter prototype and tested with an electron beam. The production yield is sufficient to allow the construction of a calorimeter of the required quality in the expected times.
96 - Y. Abreu , Y. Amhis , G. Ban 2018
The SoLid experiment has been designed to search for an oscillation pattern induced by a light sterile neutrino state, utilising the BR2 reactor of SCK$bullet$CEN, in Belgium. The detector leverages a new hybrid technology, utilising two distinct scintillators in a cubic array, creating a highly segmented detector volume. A combination of 5 cm cubic polyvinyltoluene cells, with $^6$LiF:ZnS(Ag) sheets on two faces of each cube, facilitate reconstruction of the neutrino signals. % The polyvinyltoluene scintillator is used as an $overline{ u}_e$ target for the inverse beta decay of ($overline{ u}_e + p rightarrow e^{+}+n$), with the $^6$LiF:ZnS(Ag) sheets used for associated neutron detection. Scintillation signals are read out by a network of wavelength shifting fibres connected to multipixel photon counters. Whilst the high granularity provides a powerful toolset to discriminate backgrounds; by itself the segmentation also represents a challenge in terms of homogeneity and calibration, for a consistent detector response. The search for this light sterile neutrino implies a sensitivity to distortions of around $mathcal{O}$(10)% in the energy spectrum of reactor $overline{ u}_e$. Hence, a very good neutron detection efficiency, light yield and homogeneous detector response are critical for data validation. The minimal requirements for the SoLid physics program are a light yield and a neutron detection efficiency larger than 40 PA/MeV/cube and 50 % respectively. In order to guarantee these minimal requirements, the collaboration developed a rigorous quality assurance process for all 12800 cubic cells of the detector. To carry out the quality assurance process, an automated calibration system called CALIPSO was designed and constructed.
comments
Fetching comments Fetching comments
Sign in to be able to follow your search criteria
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا