Inflight Radiometric Calibration of New Horizons Multispectral Visible Imaging Camera (MVIC)


Abstract in English

We discuss two semi-independent calibration techniques used to determine the in-flight radiometric calibration for the New Horizons Multi-spectral Visible Imaging Camera (MVIC). The first calibration technique compares the observed stellar flux to modeled values. The difference between the two provides a calibration factor that allows the observed flux to be adjusted to the expected levels for all observations, for each detector. The second calibration technique is a channel-wise relative radiometric calibration for MVICs blue, near-infrared and methane color channels using observations of Charon and scaling from the red channel stellar calibration. Both calibration techniques produce very similar results (better than 7% agreement), providing strong validation for the techniques used. Since the stellar calibration can be performed without a color target in the field of view and covers all of MVICs detectors, this calibration was used to provide the radiometric keywords delivered by the New Horizons project to the Planetary Data System (PDS). These keywords allow each observation to be converted from counts to physical units; a description of how these keywords were generated is included. Finally, mitigation techniques adopted for the gain drift observed in the near-infrared detector and one of the panchromatic framing cameras is also discussed.

Download