Do you want to publish a course? Click here

High-precision astrometry with VVV. I. An independent reduction pipeline for VIRCAM@VISTA

122   0   0.0 ( 0 )
 Added by Andrea Bellini
 Publication date 2015
  fields Physics
and research's language is English
 Authors M. Libralato




Ask ChatGPT about the research

We present a new reduction pipeline for the VIRCAM@VISTA detector and describe the method developed to obtain high-precision astrometry with the VISTA Variables in the Via Lactea (VVV) data set. We derive an accurate geometric-distortion correction using as calibration field the globular cluster NGC 5139, and showed that we are able to reach a relative astrometric precision of about 8 mas per coordinate per exposure for well-measured stars over a field of view of more than 1 square degree. This geometric-distortion correction is made available to the community. As a test bed, we chose a field centered around the globular cluster NGC 6656 from the VVV archive and computed proper motions for the stars within. With 45 epochs spread over four years, we show that we are able to achieve a precision of 1.4 mas/yr and to isolate each population observed in the field (cluster, Bulge and Disk) using proper motions. We used proper-motion-selected field stars to measure the motion difference between Galactic disk and bulge stars. Our proper-motion measurements are consistent with UCAC4 and PPMXL, though our errors are much smaller. Models have still difficulties in reproducing the observations in this highly-reddened Galactic regions.



rate research

Read More

We present the VVV-SkZ_pipeline, a DAOPHOT-based photometric pipeline, created to perform PSF-fitting photometry of VISTA Variables in the Via Lactea (VVV) ESO Public Survey data. The pipeline replaces the user avoiding repetitive interaction in all the operations, retaining all of the benefits of the power and accuracy of the DAOPHOT suite. The pipeline provides an astrometrized photometric catalog reliable up to more than 2 magnitudes brighter than the saturation limit, where other techniques fail. It also produces deeper and more accurate photometry. These achievements allow the VVV-SkZ_pipeline to produce data well anchored to the selected standard photometric system and analyze important phenomena (i.e. TRGB, RGB slope, HB morphology, RR Lyrae), that other methods are not able to manage.
With the aim of paving the road for future accurate astrometry with MICADO at the European-ELT, we performed an astrometric study using two different but complementary approaches to investigate two critical components that contribute to the total astrometric accuracy. First, we tested the predicted improvement in the astrometric measurements with the use of an atmospheric dispersion corrector (ADC) by simulating realistic images of a crowded Galactic globular cluster. We found that the positional measurement accuracy should be improved by up to ~2 mas with the ADC, making this component fundamental for high-precision astrometry. Second, we analysed observations of a globular cluster taken with the only currently available Multi-Conjugate Adaptive Optics assisted camera, GeMS/GSAOI at Gemini South. Making use of previously measured proper motions of stars in the field of view, we were able to model the distortions affecting the stellar positions. We found that they can be as large as ~200 mas, and that our best model corrects them to an accuracy of ~1 mas. We conclude that future astrometric studies with MICADO requires both an ADC and an accurate modelling of distortions to the field of view, either through an a-priori calibration or an a-posteriori correction.
Astrometric detection and mass determination of Earth-mass exoplanets requires sub-microarcsec accuracy, which is theoretically possible with an imaging space telescope using field stars as an astrometric reference. The measurement must however overcome astrometric distortions which are much larger than the photon noise limit. To address this issue, we propose to generate faint stellar diffraction spikes using a two-dimensional grid of regularly spaced small dark spots added to the surface of the primary mirror (PM). Accurate astrometric motion of the host star is obtained by comparing the position of the spikes to the background field stars. The spikes do not contribute to scattered light in the central part of the field and therefore allow unperturbed coronagraphic observation of the stars immediate surrounding. Because the diffraction spikes are created on the PM and imaged on the same focal plane detector as the background stars, astrometric distortions affect equally the diffraction spikes and the background stars, and are therefore calibrated. We describe the technique, detail how the data collected by the wide-field camera are used to derive astrometric motion, and identify the main sources of astrometric error using numerical simulations and analytical derivations. We find that the 1.4 m diameter telescope, 0.3 sq.deg field we adopt as a baseline design achieves 0.2 microarcsec single measurement astrometric accuracy. The diffractive pupil concept thus enables sub-microarcsec astrometry without relying on the accurate pointing, external metrology or high stability hardware required with previously proposed high precision astrometry concepts.
Context: Exoplanet science has made staggering progress in the last two decades, due to the relentless exploration of new detection methods and refinement of existing ones. Yet astrometry offers a unique and untapped potential of discovery of habitable-zone low-mass planets around all the solar-like stars of the solar neighborhood. To fulfill this goal, astrometry must be paired with high precision calibration of the detector. Aims: We present a way to calibrate a detector for high accuracy astrometry. An experimental testbed combining an astrometric simulator and an interferometric calibration system is used to validate both the hardware needed for the calibration and the signal processing methods. The objective is an accuracy of 5e-6 pixel on the location of a Nyquist sampled polychromatic point spread function. Methods: The interferometric calibration system produced modulated Young fringes on the detector. The Young fringes were parametrized as products of time and space dependent functions, based on various pixel parameters. The minimization of func- tion parameters was done iteratively, until convergence was obtained, revealing the pixel information needed for the calibration of astrometric measurements. Results: The calibration system yielded the pixel positions to an accuracy estimated at 4e-4 pixel. After including the pixel position information, an astrometric accuracy of 6e-5 pixel was obtained, for a PSF motion over more than five pixels. In the static mode (small jitter motion of less than 1e-3 pixel), a photon noise limited precision of 3e-5 pixel was reached.
Adaptive optics (AO) systems deliver high-resolution images that may be ideal for precisely measuring positions of stars (i.e. astrometry) if the system has stable and well-calibrated geometric optical distortions. A calibration unit, equipped with back-illuminated pinhole mask, can be utilized to measure instrumental optical distortions. AO systems on the largest ground-based telescopes, such as the W. M. Keck Observatory and the Thirty Meter Telescope require pinhole positions known to 20 nm to achieve an astrometric precision of 0.001 of a resolution element. We characterize a photo-lithographic pinhole mask and explore the systematic errors that result from different experimental setups. We characterized the nonlinear geometric distortion of a simple imaging system using the mask; and we measured 857 nm RMS of optical distortion with a final residual of 39 nm (equivalent to 20 {mu}as for TMT). We use a sixth order bivariate Legendre polynomial to model the optical distortion and allow the reference positions of the individual pinholes to vary. The nonlinear deviations in the pinhole pattern with respect to the manufacturing design of a square pattern are 47.2 nm +/- 4.5 nm (random) +/- 10.8 nm (systematic) over an area of 1788 mm$^2$. These deviations reflect the additional error induced when assuming the pinhole mask is manufactured perfectly square. We also find that ordered mask distortions are significantly more difficult to characterize than random mask distortions as the ordered distortions can alias into optical camera distortion. Future design simulations for astrometric calibration units should include ordered mask distortions. We conclude that photo-lithographic pinhole masks are >10 times better than the pinhole masks deployed in first generation AO systems and are sufficient to meet the distortion calibration requirements for the upcoming thirty meter class telescopes.
comments
Fetching comments Fetching comments
Sign in to be able to follow your search criteria
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا