Do you want to publish a course? Click here

In-orbit background of X-ray microcalorimeters and its effects on observations

341   0   0.0 ( 0 )
 Added by Simone Lotti
 Publication date 2014
  fields Physics
and research's language is English




Ask ChatGPT about the research

Methods.There are no experimental data about the background experienced by microcalorimeters in the L2 orbit, and thus the particle background levels were calculated by means of Monte Carlo simulations: we considered the original design configuration and an improved configuration aimed to reduce the unrejected background, and tested them in the L2 orbit and in the low Earth orbit, comparing the results with experimental data reported by other X-ray instruments.To show the results obtainable with the improved configuration we simulated the observation of a faint, high-redshift, point source (F[0.5-10 keV]~6.4E-16 erg cm-2 s-1, z=3.7), and of a hot galaxy cluster at R200 (Sb[0.5-2 keV]=8.61E-16 erg cm-2 s-1 arcmin-2,T=6.6 keV). Results.First we confirm that implementing an active cryogenic anticoincidence reduces the particle background by an order of magnitude and brings it close to the required level.The implementation and test of several design solutions can reduce the particle background level by a further factor of 6 with respect to the original configuration.The best background level achievable in the L2 orbit with the implementation of ad-hoc passive shielding for secondary particles is similar to that measured in the more favorable LEO environment without the passive shielding, allowing us to exploit the advantages of the L2 orbit.We define a reference model for the diffuse background and collect all the available information on its variation with epoch and pointing direction.With this background level the ATHENA mission with the X-IFU instrument is able to detect ~4100 new obscured AGNs with F>6.4E-16 erg cm-2 s-1 during three years, to characterize cluster of galaxies with Sb(0.5-2 keV)>9.4E-16 erg cm-2 s-1 sr-1 on timescales of 50 ks (500 ks) with errors <40% (<12%) on metallicity,<16% (4.8%) on temperature,2.6% (0.72%) on the gas density, and several single-element abundances.



rate research

Read More

112 - P. Cumani , M. Hernanz , J. Kiener 2019
The different background components in a low-Earth orbit have been modeled in the 10 keV to 100 GeV energy range. The model is based on data from previous instruments and it considers both primary and secondary particles, charged particles, neutrons and photons. The necessary corrections to consider the geomagnetic cutoff are applied to calculate the flux at different inclinations and altitudes for a mean solar activity. Activation simulations from such a background have been carried out using the model of a possible future gamma-ray mission (e-ASTROGAM). The event rates and spectra from these simulations were then compared to those from the isotopes created by the particles present in the South Atlantic Anomaly (SAA). The primary protons are found to be the main contributor of the activation, while the contributions of the neutrons, and that of the secondary protons can be considered negligible. The long-term activation from the passage through the SAA becomes the main source of background at high inclination (i$gtrsim10^circ$). The used models have been collected in a Python class openly available on github.
Large Area X-ray Propositional Counter (LAXPC) instrument on AstroSat is aimed at providing high time resolution X-ray observations in 3 to 80 keV energy band with moderate energy resolution. To achieve large collecting area, a cluster of three co-aligned identical LAXPC detectors, is used to realize an effective area in access of about 6000 cm2 at 15 keV. The large detection volume of the LAXPC detectors, filled with xenon gas at about 2 atmosphere pressure, results in detection efficiency greater than 50%, above 30 keV. In this article, we present salient features of the LAXPC detectors, their testing and characterization in the laboratory prior to launch and calibration in the orbit. Some preliminary results on timing and spectral characteristics of a few X-ray binaries and other type of sources, are briefly discussed to demonstrate that the LAXPC instrument is performing as planned in the orbit.
68 - Jiahui Huang , Hua Feng , Hong Li 2021
PolarLight is a gas pixel X-ray polarimeter mounted on a CubeSat, which was launched into a Sun-synchronous orbit in October 2018. We build a mass model of the whole CubeSat with the Geant4 toolkit to simulate the background induced by the cosmic X-ray background (CXB) and high energy charged particles in the orbit. The simulated energy spectra and morphologies of event images both suggest that the measured background with PolarLight is dominated by high energy electrons, with a minor contribution from protons and the CXB. The simulation reveals that, in the energy range of 2-8 keV, there are roughly 28% of the background events are caused by energy deposit from a secondary electron with an energy of a few keV, in a physical process identical to the detection of X-rays. Thus, this fraction of background cannot be discriminated from X-ray events. The background distribution is uneven on the detector plane, with an enhancement near the edges. The edge effect is because high energy electrons tend to produce long tracks, which are discarded by the readout electronics unless they have partial energy deposits near the edges. The internal background rate is expected to be around 6 x 10^-3 counts/s/cm2 in 2-8 keV if an effective particle discrimination algorithm can be applied. This indicates that the internal background should be negligible for future focusing X-ray polarimeters with a focal size in the order of mm.
347 - Keith Jahoda 2019
We describe Cal X-1, a SmallSat mission concept to establish X-ray standard candles in the sky, which will enable absolute calibration of the current and future X-ray observatories. It consists of two CubeSats flying in formation, one containing an absolutely calibrated X-ray source and another, 1-2 km away, a simple X-ray telescope.
The prospects for accomplishing x-ray polarization measurements of astronomical sources have grown in recent years, after a hiatus of more than 37 years. Unfortunately, accompanying this long hiatus has been some confusion over the statistical uncertainties associated with x-ray polarization measurements of these sources. We have initiated a program to perform the detailed calculations that will offer insights into the uncertainties associated with x-ray polarization measurements. Here we describe a mathematical formalism for determining the 1- and 2-parameter errors in the magnitude and position angle of x-ray (linear) polarization in the presence of a (polarized or unpolarized) background. We further review relevant statistics-including clearly distinguishing between the Minimum Detectable Polarization (MDP) and the accuracy of a polarization measurement.
comments
Fetching comments Fetching comments
Sign in to be able to follow your search criteria
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا