Do you want to publish a course? Click here

ShaneAO: wide science spectrum adaptive optics system for the Lick Observatory

129   0   0.0 ( 0 )
 Added by Rosalie McGurk
 Publication date 2014
  fields Physics
and research's language is English




Ask ChatGPT about the research

A new high-order adaptive optics system is now being commissioned at the Lick Observatory Shane 3-meter telescope in California. This system uses a high return efficiency sodium beacon and a combination of low and high-order deformable mirrors to achieve diffraction-limited imaging over a wide spectrum of infrared science wavelengths covering 0.8 to 2.2 microns. We present the design performance goals and the first on-sky test results. We discuss several innovations that make this system a pathfinder for next generation AO systems. These include a unique woofer-tweeter control that provides full dynamic range correction from tip/tilt to 16 cycles, variable pupil sampling wavefront sensor, new enhanced silver coatings developed at UC Observatories that improve science and LGS throughput, and tight mechanical rigidity that enables a multi-hour diffraction- limited exposure in LGS mode for faint object spectroscopy science.



rate research

Read More

47 - Mark Lacy 2002
We present near-infrared H-band observations of the hosts of three z~1 quasars from the Sloan Digital Sky Survey made with the adaptive optics system at Lick Observatory. We derive a PSF for each quasar and model the host plus quasar nucleus to obtain magnitudes and approximate scale sizes for the host galaxies. We find our recovered host galaxies are similar to those found for z~1 quasars observed with the Hubble Space Telescope. They also have, with one interesting exception, black hole mass estimates from their bulge luminosities which are consistent with those from emission-line widths. We thus demonstrate that adaptive optics can be successfully used for the quantitative study of quasar host galaxies, with the caveat that better PSF calibration will be needed for studies of the hosts of significantly brighter or higher redshift quasars with the Lick system.
We have created a new autonomous laser-guide-star adaptive-optics (AO) instrument on the 60-inch (1.5-m) telescope at Palomar Observatory called Robo-AO. The instrument enables diffraction-limited resolution observing in the visible and near-infrared with the ability to observe well over one-hundred targets per night due to its fully robotic operation. Robo- AO is being used for AO surveys of targets numbering in the thousands, rapid AO imaging of transient events and longterm AO monitoring not feasible on large diameter telescope systems. We have taken advantage of cost-effective advances in deformable mirror and laser technology while engineering Robo-AO with the intention of cloning the system for other few-meter class telescopes around the world.
ERIS is the new AO instrument for VLT-UT4 led by a Consortium of Max-Planck Institut fuer Extraterrestrische Physik, UK-ATC, ETH-Zurich, ESO and INAF. The ERIS AO system provides NGS mode to deliver high contrast correction and LGS mode to extend high Strehl performance to large sky coverage. The AO module includes NGS and LGS wavefront sensors and, with VLT-AOF Deformable Secondary Mirror and Laser Facility, will provide AO correction to the high resolution imager NIX (1-5um) and the IFU spectrograph SPIFFIER (1-2.5um). In this paper we present the preliminary design of the ERIS AO system and the estimated correction performance.
We present the Phase A Science Case for the Multi-conjugate Adaptive-optics Visible Imager-Spectrograph (MAVIS), planned for the Adaptive Optics Facility (AOF) of the Very Large Telescope (VLT). MAVIS is a general-purpose instrument for exploiting the highest possible angular resolution of any single optical telescope available in the next decade, either on Earth or in space, and with sensitivity comparable to (or better than) larger aperture facilities. MAVIS uses two deformable mirrors in addition to the deformable secondary mirror of the AOF, providing a mean V-band Strehl ratio of >10% (goal >15%) across a relatively large (30 arc second) science field. This equates to a resolution of <20mas at 550nm - comparable to the K-band diffraction limit of the next generation of extremely large telescopes, making MAVIS a genuine optical counterpart to future IR-optimised facilities like JWST and the ELT. Moreover, MAVIS will have unprecedented sky coverage for a high-order AO system, accessing at least 50% of the sky at the Galactic Pole, making MAVIS a truly general purpose facility instrument. As such, MAVIS will have both a Nyquist-sampled imager (30x30 arcsec field), and a powerful integral field spectrograph with multiple spatial and spectral modes spanning 370-1000nm. This science case presents a distilled set of thematically linked science cases drawn from the MAVIS White Papers (www.mavis-ao.org/whitepapers), selected to illustrate the driving requirements of the instrument resulting from the recent MAVIS Phase A study.
90 - J. R. Lu , M. Chun , S. M. Ammons 2018
Ground-layer adaptive optics (GLAO) systems offer the possibility of improving the seeing of large ground-based telescopes and increasing the efficiency and sensitivity of observations over a wide field-of-view. We explore the utility and feasibility of deploying a GLAO system at the W. M. Keck Observatory in order to feed existing and future multi-object spectrographs and wide-field imagers. We also briefly summarize science cases spanning exoplanets to high-redshift galaxy evolution that would benefit from a Keck GLAO system. Initial simulations indicate that a Keck GLAO system would deliver a 1.5x and 2x improvement in FWHM at optical (500 nm) and infrared (1.5 micron), respectively. The infrared instrument, MOSFIRE, is ideally suited for a Keck GLAO feed in that it has excellent image quality and is on the telescopes optical axis. However, it lacks an atmospheric dispersion compensator, which would limit the minimum usable slit size for long-exposure science cases. Similarly, while LRIS and DEIMOS may be able to accept a GLAO feed based on their internal image quality, they lack either an atmospheric dispersion compensator (DEIMOS) or flexure compensation (LRIS) to utilize narrower slits matched to the GLAO image quality. However, some science cases needing shorter exposures may still benefit from Keck GLAO and we will investigate the possibility of installing an ADC.
comments
Fetching comments Fetching comments
Sign in to be able to follow your search criteria
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا