Beam energy determination in experiments at electron-positron colliders

169   0   0.0 ( 0 )
 Added by Achasov Mikhail
 Publication date 2014
  fields Physics
and research's language is English




Ask ChatGPT about the research

The review of using of compton backscattering method for determination of the beam energy in collider experiments is given.



rate research

Read More

Calibration of the absolute energy scale at high-energy photon (gamma-gamma, gamma-electron) colliders is discussed. The luminosity spectrum at photon colliders is broad and has a rather sharp high-energy edge, which can be used, for example, to measure the mass of the Higgs boson in the process gamma-gamma to H or masses of charged scalars by observing the cross-section threshold. In addition to the precise knowledge of the edge energy of the luminosity spectrum, it is even more important to have a way to calibrate the absolute energy scale of the detector. At first sight, Compton scattering itself provides a unique way to determine the beam energies and produce particles of known energies that could be used for detector calibration. The energy scale is given by the electron mass m_e and laser photon energy omega_0. However, this does not work at realistic photon colliders due to large nonlinear effects in Compton scattering at the conversion region (xi^2 sim 0.3). It is argued that the process gamma-electron to eZ_0 provides the best way to calibrate the energy scale of the detector, where the energy scale is given by m_Z.
The beam energy measurement system for the VEPP-2000 electron-positron collider is described. The method of Compton backscattering of $CO$ laser photons on the electron beam is used. The relative systematic uncertainty of the beam energy determination is estimated as 6cdot10^{-5}. It was obtained through comparison of the results of the beam energy measurements using the Compton backscattering and resonance depolarization methods.
The beam energy measurement system (BEMS) for the upgraded Beijing electron-positron collider BEPC-II is described. The system is based on measuring the energies of Compton back-scattered photons. The relative systematic uncertainty of the electron and positron beam energy determination is estimated as 2 cdot 10^{-5}. The relative uncertainty of the beams energy spread is about 6 %.
An extension of the TRIUMF M13 low-energy pion channel designed to suppress positrons based on an energy-loss technique is described. A source of beam channel momentum calibration from the decay pi+ --> e+ nu is also described.
75 - D.Indurthy , S.Kopp , Z.Pavlovich 2004
The Neutrinos at the Main Injector (NuMI) project will extract 120 GeV protons from the FNAL Main Injector in 8.56usec spills of 4E13 protons every 1.9 sec. We have designed secondary emission monitor (SEM) detectors to measure beam profile and halo along the proton beam transport line. The SEM?s are Ti foils 5um in thickness segmented in either 1?mm or 0.5?mm pitch strips, resulting in beam loss ~5E-6. We discuss aspects of the mechanical design, calculations of expected beam heating, and results of a beam test at the 8 GeV transport line to MiniBoone at FNAL.