Do you want to publish a course? Click here

On the prospects of building optical atomic clocks using Er I or Er III

69   0   0.0 ( 0 )
 Publication date 2013
  fields Physics
and research's language is English




Ask ChatGPT about the research

The possibility of using neutral and double ionized erbium for atomic clocks of high precision is investigated. In both cases the narrow electric quadrupole clock transition between the ground and first exited state of the same configuration lies in optical region. The estimated ratio of decay width to transition energy is less then 10 20. We demonstrate that this transitions are not sensitive to black body radiation and if other perturbations are also considered the relative accuracy of the clocks can probably reach the level of 10 (pow minus 18) or better.



rate research

Read More

109 - N. Poli , C. W. Oates , P. Gill 2014
In the last ten years extraordinary results in time and frequency metrology have been demonstrated. Frequency-stabilization techniques for continuous-wave lasers and femto-second optical frequency combs have enabled a rapid development of frequency standards based on optical transitions in ultra-cold neutral atoms and trapped ions. As a result, todays best performing atomic clocks tick at an optical rate and allow scientists to perform high-resolution measurements with a precision approaching a few parts in $10^{18}$. This paper reviews the history and the state of the art in optical-clock research and addresses the implementation of optical clocks in a possible future redefinition of the SI second as well as in tests of fundamental physics.
Direct loading of lanthanide atoms into magneto-optical traps (MOTs) from a very slow cryogenic buffer gas beam source is achieved, without the need for laser slowing. The beam source has an average forward velocity of 60-70,m/s and a velocity half-width of ~35 m/s, which allows for direct MOT loading of Yb, Tm, Er and Ho. Residual helium background gas originating from the beam results in a maximum trap lifetime of about 80 ms (with Yb). The addition of a single-frequency slowing laser applied to the Yb in the buffer gas beam increases the number of trapped Yb atoms to 1.3(0.7) x 10^8 with a loading rate of 2.0(1.0) x 10^10 atoms/s. Decay to metastable states is observed for all trapped species and decay rates are measured. Extension of this approach to the loading of molecules into a MOT is discussed.
We propose a space-based gravitational wave detector consisting of two spatially separated, drag-free satellites sharing ultra-stable optical laser light over a single baseline. Each satellite contains an optical lattice atomic clock, which serves as a sensitive, narrowband detector of the local frequency of the shared laser light. A synchronized two-clock comparison between the satellites will be sensitive to the effective Doppler shifts induced by incident gravitational waves (GWs) at a level competitive with other proposed space-based GW detectors, while providing complementary features. The detected signal is a differential frequency shift of the shared laser light due to the relative velocity of the satellites, and the detection window can be tuned through the control sequence applied to the atoms internal states. This scheme enables the detection of GWs from continuous, spectrally narrow sources, such as compact binary inspirals, with frequencies ranging from ~3 mHz - 10 Hz without loss of sensitivity, thereby bridging the detection gap between space-based and terrestrial optical interferometric GW detectors. Our proposed GW detector employs just two satellites, is compatible with integration with an optical interferometric detector, and requires only realistic improvements to existing ground-based clock and laser technologies.
192 - G. Mandula , Z. Kis , P. Sinkovicz 2010
We work out a simple, pulsed pump-probe measurement scheme to measure the homogeneous linewidth of an atomic transition in an inhomogeneously broadened spectral line in a solid state environment. We apply the theory to the I_11/2 -- I_15/2 optical transition of erbium in LiNbO_3:Er^3+ crystal. Beside obtaining the homogeneous linewidth, we have estimated the population relaxation time as well.
Atomic clocks use atomic transitions as frequency references. The susceptibility of the atomic transition to external fields limits clock stability and introduces systematic frequency shifts. Here, we propose to realize an atomic clock that utilizes an entangled superposition of states of multiple atomic species, where the reference frequency is a sum of the individual transition frequencies. The superposition is selected such that the susceptibilities of the respective transitions, in individual species, destructively interfere leading to improved stability and reduced systematic shifts. We present and analyze two examples of such combinations. The first uses the optical quadrupole transitions in a $^{40}$Ca$^+$ - $^{174}$Yb$^+$ two-ion crystal. The second is a superposition of optical quadrupole transitions in one $^{88}$Sr$^+$ ion and three $^{202}$Hg$^+$ ions. These combinations have reduced susceptibility to external magnetic fields and blackbody radiation.
comments
Fetching comments Fetching comments
Sign in to be able to follow your search criteria
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا