Burst statistics in Alcator C-Mod SOL turbulence

122   0   0.0 ( 0 )
 Added by Odd Erik Garcia
 Publication date 2012
  fields Physics
and research's language is English




Ask ChatGPT about the research

Bursty fluctuations in the scrape-off layer (SOL) of Alcator C-Mod have been analyzed using gas puff imaging data. This reveals many of the same fluctuation properties as Langmuir probe measurements, including normal distributed fluctuations in the near SOL region while the far SOL plasma is dominated by large amplitude bursts due to radial motion of blob-like structures. Conditional averaging reveals burst wave forms with a fast rise and slow decay and exponentially distributed waiting times. Based on this, a stochastic model of burst dynamics is constructed. The model predicts that fluctuation amplitudes should follow a Gamma distribution. This is shown to be a good description of the gas puff imaging data, validating this aspect of the model.



rate research

Read More

88 - R. Hong , S. J. Wukitch , Y. Lin 2017
Gas-puff imaging techniques are employed to determine the far SOL region radial electric field and the plasma potential in ICRF heated discharges in the Alcator C-Mod tokamak. The 2-dimensional velocity fields of the turbulent structures, which are advected by RF-induced $ mathbf{Etimes B} $ flows, are obtained via the time-delay estimation (TDE) techniques. Both the magnitude and radial extension of the radial electric field $ E_r $ are observed to increase with the toroidal magnetic field strength $ B_varphi $ and the ICRF power. In particular, the RF-induced $ E_r $ extends from the vicinity of the ICRF antenna to the separatrix when $ B_varphi=7.9,mathrm{T} $ and $ P_{mathrm{ICRF}} gtrsim 1,mathrm{MW} $. In addition, low-Z impurity seeding near the antenna is found to substantially reduce the sheath potential associated with ICRF power. The ICRF-induced potentials are also estimated in different antenna configurations: (1) conventional toroidally-aligned (TA) antenna versus field-aligned (FA) antenna; (2) FA monopole versus FA dipole. Results show that FA and TA antennas produce similar magnitude of plasma potentials, and the FA monopole induced greater potential than the FA dipole phasing.
In some conditions, I-mode plasmas can feature pedestal relaxation events (PREs) that transiently enhance the energy reaching the divertor target plates. To shed light into their appearance, characteristics and energy reaching the divertor targets, a comparative study between two tokamaks $-$ Alcator C-Mod and ASDEX Upgrade $-$ is carried out. It is found that PREs appear only in a subset of I-mode discharges, mainly when the plasma is close to the H-mode transition. Also, the nature of the triggering instability is discussed by comparing measurements close to the separatrix in both devices. The PRE relative energy loss from the confined region increases with decreasing pedestal top collisionality $ u_{mathrm{ped}}^*$. In addition, the relative electron temperature drop at the pedestal top, which is related to the conductive energy loss, rises with decreasing $ u_{mathrm{ped}}^*$. Finally, the peak parallel energy fluence due to the PRE measured on the divertor in both devices is compared to the model introduced in [1] for type-I ELMs. The model is shown to provide an upper boundary for PRE energy fluence data, while a lower boundary is found by dividing the model by three. These two boundaries are used to make projections to future devices such as DEMO and ARC.
The guiding-center kinetic neoclassical transport code, XGC0, [C.S. Chang et. al, Phys. Plasmas 11, 2649 (2004)] is used to compute the heat fluxes and the heat-load width in the outer divertor plates of Alcator C-Mod and DIII-D tokamaks. The dependence of the width of heat-load fluxes on neoclassical effects, neutral collisions and anomalous transport is investigated using the XGC0 code. The XGC0 code includes realistic X-point geometry, a neutral source model, the effects of collisions, and a diffusion model for anomalous transport. It is observed that width of the XGC0 neoclassical heat-load is approximately inversely proportional to the total plasma current $I_{rm p}$. The scaling of the width of the divertor heat-load with plasma current is examined for an Alcator C-Mod discharge and four DIII-D discharges. The scaling of the divertor heat-load width with plasma current is found to be weaker in the Alcator C-Mod discharge compared to scaling found in the DIII-D discharges. The effect of neutral collisions on the $1/I_{rm p}$ scaling of heat-load width is shown not to be significant. Although inclusion of poloidally uniform anomalous transport results in a deviation from the $1/I_{rm p}$ scaling, the inclusion of the anomalous transport that is driven by ballooning-type instabilities results in recovering the neoclassical $1/I_{rm p}$ scaling. The Bohm or Gyro-Bohm scalings of anomalous transport does not strongly affect the dependence of the heat-load width on plasma current. The inclusion of anomalous transport, in general, results in widening the width of neoclassical divertor heat-load and enhances the neoclassical heat-load fluxes on the divertor plates. Understanding heat transport in the tokamak scrape-off layer plasmas is important for strengthening the basis for predicting divertor conditions in ITER.
We present experimental inferences of cross-field impurity transport coefficients for Alcator C-Mod plasmas using a novel forward model for the entire Ca K-alpha spectrum, including satellite lines within the spectral range, to compare to high-resolution X-ray Imaging Crystal Spectroscopy (XICS). These measurements are complemented by Extreme Ultra-Violet (EUV) spectroscopy that constrains transport closer to the edge. Using new atomic data sets for both XICS and EUV analysis has enabled consideration of line ratios across both spectral ranges and has increased the accuracy of inferred transport coefficients. Inclusion of charge exchange between edge thermal neutrals and impurities is shown to be extremely important in C-Mod pedestals. We obtain D atomic neutral densities from experimental D Ly-alpha measurements at the midplane and compare these to SOLPS-ITER simulations, finding good agreement. Bayesian inferences of impurity transport coefficients are presented for L-, EDA H-, and I-mode discharges, making use of the Aurora package for forward modeling and combining our spectroscopic constraints. Experimentally inferred diffusion profiles are found to match turbulent transport models at midradius within uncertainties, using both quasilinear gyro-fluid TGLF SAT-1 and nonlinear ion-scale gyrokinetic CGYRO simulations. Significant discrepancies in convection are observed in some cases, suggesting difficulties in predictions of flat or hollow impurity profiles.
Statistical properties of the scrape-off layer (SOL) plasma fluctuations are studied in ohmically heated plasmas in the Alcator C-Mod tokamak. For the first time, plasma fluctuations as well as parameters that describe the fluctuations are compared across measurements from a mirror Langmuir probe (MLP) and from gas-puff imaging (GPI) that sample the same plasma discharge. This comparison is complemented by an analysis of line emission time-series data, synthesized from the MLP electron density and temperature measurements. The fluctuations observed by the MLP and GPI typically display relative fluctuation amplitudes of order unity together with positively skewed and flattened probability density functions. Such data time series are well described by an established stochastic framework which model the data as a superposition of uncorrelated, two-sided exponential pulses. The most important parameter of the process is the intermittency parameter, {gamma} = {tau}d / {tau}w where {tau}d denotes the duration time of a single pulse and {tau}w gives the average waiting time between consecutive pulses. Here we show, using a new deconvolution method, that these parameters can be consistently estimated from different statistics of the data. We also show that the statistical properties of the data sampled by the MLP and GPI diagnostic are very similar. Finally, a comparison of the GPI signal to the synthetic line-emission time series suggests that the measured emission intensity can not be explained solely by a simplified model which neglects neutral particle dynamics.