Imaging the lateral shift of a quantum-point contact using scanning-gate microscopy

261   0   0.0 ( 0 )
 Added by Stephan Schnez
 Publication date 2011
  fields Physics
and research's language is English




Ask ChatGPT about the research

We perform scanning-gate microscopy on a quantum-point contact. It is defined in a high-mobility two-dimensional electron gas of an AlGaAs/GaAs heterostructure, giving rise to a weak disorder potential. The lever arm of the scanning tip is significantly smaller than that of the split gates defining the conducting channel of the quantum-point contact. We are able to observe that the conducting channel is shifted in real space when asymmetric gate voltages are applied. The observed shifts are consistent with transport data and numerical estimations.



rate research

Read More

77 - B. Brun , F. Martins , S. Faniel 2018
We introduce a new scanning probe technique derived from scanning gate microscopy (SGM) in order to investigate thermoelectric transport in two-dimensional semiconductor devices. The thermoelectric scanning gate Microscopy (TSGM) consists in measuring the thermoelectric voltage induced by a temperature difference across a device, while scanning a polarized tip that locally changes the potential landscape. We apply this technique to perform interferometry of the thermoelectric transport in a quantum point contact (QPC). We observe an interference pattern both in SGM and TSGM images, and evidence large differences between the two signals in the low density regime of the QPC. In particular, a large phase jump appears in the interference fringes recorded by TSGM, which is not visible in SGM. We discuss this difference of sensitivity using a microscopic model of the experiment, based on the contribution from a resonant level inside or close to the QPC. This work demonstrates that combining scanning gate microscopy with thermoelectric measurements offers new information as compared to SGM, and provides a direct access to the derivative of the device transmission with respect to energy, both in amplitude and in phase.
117 - Sei Morikawa 2015
We use scanning gate microscopy to map out the trajectories of ballistic carriers in high-mobility graphene encapsulated by hexagonal boron nitride and subject to a weak magnetic field. We employ a magnetic focusing geometry to image carriers that emerge ballistically from an injector, follow a cyclotron path due to the Lorentz force from an applied magnetic field, and land on an adjacent collector probe. The local electric field generated by the scanning tip in the vicinity of the carriers deflects their trajectories, modifying the proportion of carriers focused into the collector. By measuring the voltage at the collector while scanning the tip, we are able to obtain images with arcs that are consistent with the expected cyclotron motion. We also demonstrate that the tip can be used to redirect misaligned carriers back to the collector.
254 - B. Brun , F. Martins , S. Faniel 2013
Quantum point contacts exhibit mysterious conductance anomalies in addition to well known conductance plateaus at multiples of 2e^2/h. These 0.7 and zero-bias anomalies have been intensively studied, but their microscopic origin in terms of many-body effects is still highly debated. Here we use the charged tip of a scanning gate microscope to tune in situ the electrostatic potential of the point contact. While sweeping the tip distance, we observe repetitive splittings of the zero-bias anomaly, correlated with simultaneous appearances of the 0.7 anomaly. We interpret this behaviour in terms of alternating equilibrium and non-equilibrium Kondo screenings of different spin states localized in the channel. These alternating Kondo effects point towards the presence of a Wigner crystal containing several charges with different parities. Indeed, simulations show that the electron density in the channel is low enough to reach one-dimensional Wigner crystallization over a size controlled by the tip position.
We perform scanning gate microscopy on individual suspended carbon nanotube quantum dots. The size and position of the quantum dots can be visually identified from the concentric high conductance rings. For the ultra clean devices used in this study, two new effects are clearly identified. Electrostatic screening creates non-overlapping multiple sets of Coulomb rings from a single quantum dot. In double quantum dots, by changing the tip voltage, the interactions between the quantum dots can be tuned from the weak to strong coupling regime.
In scanning gate microscopy, where the tip of a scanning force microscope is used as a movable gate to study electronic transport in nanostructures, the shape and magnitude of the tip-induced potential are important for the resolution and interpretation of the measurements. Contaminations picked up during topography scans may significantly alter this potential. We present an in situ high-field treatment of the tip that improves the tip-induced potential. A quantum dot was used to measure the tip-induced potential.