Do you want to publish a course? Click here

Effects of Nitrogen contamination in liquid Argon

115   0   0.0 ( 0 )
 Added by Luca Grandi
 Publication date 2008
  fields
and research's language is English




Ask ChatGPT about the research

A dedicated test of the effects of Nitrogen contamination in liquid Argon has been performed at the INFN-Gran Sasso Laboratory (LNGS, Italy) within the WArP R&D program. A detector has been designed and assembled for this specific task and connected to a system for the injection of controlled amounts of gaseous Nitrogen into the liquid Argon. Purpose of the test is to detect the reduction of the Ar scintillation light emission as a function of the amount of the Nitrogen contaminant injected in the Argon volume. A wide concentration range, spanning from about 10^-1 ppm up to about 10^3 ppm, has been explored. Measurements have been done with electrons in the energy range of minimum ionizing particles (gamma-conversion from radioactive sources). Source spectra at different Nitrogen contaminations are analyzed, showing sensitive reduction of the scintillation yield at increasing concentrations. The rate constant of the light quenching process induced by Nitrogen in liquid Ar has been found to be k(N2)=0.11 micros^-1 ppm^-1. Direct PMT signals acquisition at high time resolution by fast Waveform recording allowed to extract with high precision the main characteristics of the scintillation light emission in pure and contaminated LAr. In particular, the decreasing behavior in lifetime and relative amplitude of the slow component is found to be appreciable from O(1 ppm) of Nitrogen concentrations.



rate research

Read More

A dedicated test of the effects of Oxygen contamination in liquid Argon has been performed at the INFN-Gran Sasso Laboratory (LNGS, Italy) within the WArP R&D program. Two detectors have been used: the WArP 2.3 lt prototype and a small (0.7 lt) dedicated detector, coupled with a system for the injection of controlled amounts of gaseous Oxygen. Purpose of the test with the 0.7 lt detector is to detect the reduction of the long-lived component lifetime of the Argon scintillation light emission at increasing O2 concentration. Data from the WArP prototype are used for determining the behavior of both the ionization electron lifetime and the scintillation long-lived component lifetime during the O2-purification process activated in closed loop during the acquisition run. The electron lifetime measurements allow to infer the O2 content of the Argon and correlate it with the long-lived scintillation lifetime data. The effect of Oxygen contamination on the scintillation light has been thus measured over a wide range of O2 concentration, spanning from about 10^-3 ppm up to about 10 ppm. The rate constant of the light quenching process induced by Oxygen in LAr has been found to be k(O2)=0.54+-0.03 micros^-1 ppm^-1.
238 - M. Barnabe Heider 2008
The GERDA (GERmanium Detector Array) experiment aiming to search for the neutrinoless double beta decay of 76Ge at the Laboratori Nazionali Del Gran Sasso (LNGS), Italy, will operate bare enriched high-purity germanium (HPGe) detectors in liquid argon. GERDA Phase I will use the enriched diodes from the previous Heidelberg-Moscow (HdM) and IGEX experiments. With the HPGe detectors mounted in a low-mass holder, GERDA aims at an excellent energy resolution and extremely low background. The goal is to check the claim for the neutrinoless double beta decay evidence in the HdM 76Ge experiment within one year of data taking. Before dismounting the enriched diodes from their cryostat, the performance parameters of the HdM and the IGEX detectors have been measured. The diodes have been removed from their cryostats, their dimensions measured and they have been put under va-cuum in a transportation container. They are now being refurbished for GERDA Phase I at Canberra Semiconductor NV. Before operating the enriched diodes, a non-enriched HPGe p-type detector mounted in a low-mass holder is operated in the liquid argon test facility of the GERDA Detector Laboratory (GDL) at LNGS. Since January 2006, the testing of the prototype detector is being carried out in the GDL as well as at the site of the detector manufacturer.
The electron scattering has been a vital tool to study the properties of the target nucleus for over five decades. Though, the particular interest on $^{40}$Ar nucleus stemmed from the progress in the accelerator-based neutrino-oscillation experiments. The complexity of nuclei comprising the detectors and their weak response turned out to be one of the major hurdles in the quest of achieving unprecedented precision in these experiments. The challenges are further magnified by the use of Liquid Argon Time Projection Chambers (LArTPCs) in the short- (SBN) and long-baseline (DUNE) neutrino program, with almost non-existence electron-argon scattering data and hence with no empirical basis to test and develop nuclear models for $^{40}$Ar. In light of these challenges, an electron-argon experiment, E12-14-012, was proposed at Jefferson Lab. The experiment has recently successfully completed collecting data for $(e,ep)$ and $(e,e)$ processes, not just on $^{40}$Ar but also on $^{48}$Ti, and $^{12}$C targets. While the analysis is running with full steam, in this contribution, we present a brief overview of the experiment.
Electron avalanching in liquid argon is being studied as a function of voltage, pressure, radiation intensity, and the concentrations of certain additives, especially xenon. The avalanches produced in an intense electric field at the tip of a tungsten needle are initiated by ionization from a moveable americium (241Am) gamma ray source. Photons from xenon excimers are detected as photomultiplier signals in coincidence with the current pulse from the needle. In pure liquid argon the avalanche behavior is erratic, but the addition of even a small amount of xenon (>100ppm) stabilizes the performance. Similar attempts with neon (30%) as an additive to argon have been unsuccessful. Tests with higher energy gamma rays (57Co) yield spectra and other performance characteristics quite similar to those using the 241Am source. Two types of signal pulses are commonly observed: a set of pulses that are sensitive to ambient pressure, and a set of somewhat smaller pulses that are not pressure dependent.
Nitrogen gas accidentally sealed in a sample container produces various spurious effects in elastic neutron scattering measurements. These effects are systematically investigated and the details of the spurious scattering are presented.
comments
Fetching comments Fetching comments
Sign in to be able to follow your search criteria
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا