Do you want to publish a course? Click here

Simultaneous multi-wavelength observations of the TeV Blazar Mrk 421 during February - March 2003: X-ray and NIR correlated variability

119   0   0.0 ( 0 )
 Added by Alok Gupta Dr.
 Publication date 2008
  fields Physics
and research's language is English
 Authors Alok C. Gupta




Ask ChatGPT about the research

In the present paper, we have reported the result of simultaneous multi-wavelength observations of the TeV blazar Mrk 421 during February $-$ March 2003. In this period, we have observed Mrk 421 using Pachmarhi Array of v{C}erenkov Telescopes (PACT) of Tata Institute of Fundamental Research at Pachmarhi, India. Other simultaneous data were taken from the published literature and public data archives. We have analyzed the high quality X-ray (2-20 keV) observations from the NASA Rossi X-Ray Timing Explorer (RXTE). We have seen a possible correlated variability between X-ray and J band (1.25 $mu$) near infrared (NIR) wavelength. This is the first case of X-ray and NIR correlated variability in Mrk 421 or any high energy peaked (HBL) blazar. The correlated variability reported here is indicating a similar origin for NIR and X-ray emission. The emission is not affected much by the environment of the surrounding medium around the central engine of the Mrk 421. The observations are consistent with the shock-in-jet model for the emission of radiations.



rate research

Read More

We study the multi-wavelength variability of the blazar Mrk 421 at minutes to days timescales using simultaneous data at $gamma$-rays from Fermi, 0.7-20 keV energies from AstroSat, and optical and near-infrared (NIR) wavelengths from ground-based observatories. We compute the shortest variability timescales at all of the above wavebands and find its value to be ~1.1 ks at the hard X-ray energies and increasingly longer at soft X-rays, optical and NIR wavelengths as well as at the GeV energies. We estimate the value of the magnetic field to be 0.5 Gauss and the maximum Lorentz factor of the emitting electrons ~1.6 x $10^5$ assuming that synchrotron radiation cooling drives the shortest variability timescale. Blazars vary at a large range of timescales often from minutes to years. These results, as obtained here from the very short end of the range of variability timescales of blazars, are a confirmation of the leptonic scenario and in particular the synchrotron origin of the X-ray emission from Mrk 421 by relativistic electrons of Lorentz factor as high as $10^5$. This particular mode of confirmation has been possible using minutes to days timescale variability data obtained from AstroSat and simultaneous multi-wavelength observations.
We present X-ray flux and spectral analyses of the three pointed Suzaku observations of the TeV high synchrotron peak blazar Mrk 421 taken throughout its complete operational duration. The observation taken on 5 May 2008 is, at 364.6 kiloseconds (i.e., 101.3 hours), the longest and most evenly sampled continuous observation of this source, or any blazar, in the X-ray energy 0.8 - 60 keV until now. We found large amplitude intra-day variability in all soft and hard bands in all the light curves. The discrete correction function analysis of the light curves in soft and hard bands peaks on zero lag, showing that the emission in hard and soft bands are cospatial and emitted from the same population of leptons. The hardness ratio plots imply that the source is more variable in the harder bands compared to the softer bands. The source is harder-when-brighter, following the general behavior of high synchrotron peak blazars. Power spectral densities of all three light curves are red noise dominated, with a range of power spectra slopes. If one assumes that the emission originates very close to the central super massive black hole, a crude estimate for its mass, of ~ 4 * 10^{8} M_{odot}, can be made; but if the variability is due to perturbations arising there that are advected into the jet and are thus Doppler boosted, substantially higher masses are consistent with the quickest seen variations. We briefly discuss the possible physical mechanisms most likely responsible for the observed flux and spectral variability.
We present an extensive study of 72 archival Chandra light curves of the high-frequency-peaked type blazar Mrk 421, the first strong extragalactic object to be detected at TeV energies. Between 2000 and 2015 Mrk 421 often displayed intraday variability in the 0.3-10.0 keV energy range, as quantified through fractional variability amplitudes that range up to 21.3 per cent. A variability duty cycle of ~84 per cent is present in these data. Variability timescales, with values ranging from 5.5 to 30.5 ks, appear to be present in seven of these observations. Discrete correlation function analyses show positive correlations between the soft (0.3-2.0 keV) and hard (2.0-10.0 keV) X-ray energy bands with zero time lags, indicating that very similar electron populations are responsible for the emission of all the X-rays observed by Chandra. The hardness ratios of this X-ray emission indicate a general harder-when-brighter trend in the spectral behaviour of Mrk 421. Spectral index-flux plots provide model independent indications of the spectral evolution of the source and information on the X-ray emission mechanisms. Brief discussions of theoretical models that are consistent with these observations are given.
The blazar Mrk 421 shows frequent, short flares in the TeV energy regime. Due to the fast nature of such episodes, we often fail to obtain sufficient simultaneous information about flux variations in several energy bands. To overcome this lack of multi-wavelength (MWL) coverage, especially for the pre- and post-flare periods, we have set up a monitoring program with the FACT telescope (TeV energies) and the Neil Gehrels Swift Observatory (X-rays). On 2019 June 9, Mrk 421 showed a TeV outburst reaching a flux level of more than two times the flux of the Crab Nebula at TeV energies. We acquired simultaneous data in the X-rays with additional observations by XMM-Newton and INTEGRAL. For the first time, we can study a TeV blazar in outburst taking advantage of highly sensitive X-ray data from XMM-Newton and INTEGRAL combined. Our dataset is complemented by pointed radio observations by Effelsberg at GHz frequencies. We present our first results, including the {gamma}-ray and X-ray light curves, a timing analysis of the X-ray data obtained with XMM-Newton , as well as the radio spectra before, during and after the flare.
130 - V.A. Acciari , E. Aliu , T. Arlen 2011
We report on TeV gamma-ray observations of the blazar Mrk 421 (redshift of 0.031) with the VERITAS observatory and the Whipple 10m Cherenkov telescope. The excellent sensitivity of VERITAS allowed us to sample the TeV gamma-ray fluxes and energy spectra with unprecedented accuracy where Mrk 421 was detected in each of the pointings. A total of 47.3 hrs of VERITAS and 96 hrs of Whipple 10m data were acquired between January 2006 and June 2008. We present the results of a study of the TeV gamma-ray energy spectra as a function of time, and for different flux levels. On May 2nd and 3rd, 2008, bright TeV gamma-ray flares were detected with fluxes reaching the level of 10 Crab. The TeV gamma-ray data were complemented with radio, optical, and X-ray observations, with flux variability found in all bands except for the radio waveband. The combination of the RXTE and Swift X-ray data reveal spectral hardening with increasing flux levels, often correlated with an increase of the source activity in TeV gamma-rays. Contemporaneous spectral energy distributions were generated for 18 nights, each of which are reasonably described by a one-zone SSC model.
comments
Fetching comments Fetching comments
Sign in to be able to follow your search criteria
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا