ترغب بنشر مسار تعليمي؟ اضغط هنا

Long-term pulse period evolution of the ultra-luminous X-ray pulsar NGC 7793 P13

86   0   0.0 ( 0 )
 نشر من قبل Felix Fuerst
 تاريخ النشر 2021
  مجال البحث فيزياء
والبحث باللغة English
 تأليف F. Fuerst




اسأل ChatGPT حول البحث

Ultra-luminous X-ray pulsars (ULXPs) provide a unique opportunity to study super-Eddington accretion. We present the results of a monitoring campaign of ULXP NGC 7793 P13. Over our four-year monitoring campaign with Swift, XMM-Newton, and NuSTAR, we measured a continuous spin-up with $dot P$ ~ -3.8e-11 s/s. The strength of the spin-up is independent of the observed X-ray flux, indicating that despite a drop in observed flux in 2019, accretion onto the source has continued at largely similar rates. The source entered an apparent off-state in early 2020, which might have resulted in a change in the accretion geometry as no pulsations were found in observations in July and August 2020. We used the long-term monitoring to update the orbital ephemeris and the periodicities seen in both the observed optical/UV and X-ray fluxes. We find that the optical/UV period is very stable over the years, with $P_text{UV}$ = 63.75 (+0.17, -0.12) d. The best-fit orbital period determined from our X-ray timing results is 64.86 +/- 0.19 d, which is almost a day longer than previously implied, and the X-ray flux period is 65.21+/- 0.15 d, which is slightly shorter than previously measured. The physical origin of these different flux periods is currently unknown. We study the hardness ratio to search for indications of spectral changes. We find that the hardness ratios at high energies are very stable and not directly correlated with the observed flux. At lower energies we observe a small hardening with increased flux, which might indicate increased obscuration through outflows at higher luminosities. We find that the pulsed fraction is significantly higher at low fluxes. This seems to imply that the accretion geometry already changed before the source entered the deep off-state. We discuss possible scenarios to explain this behavior, which is likely driven by a precessing accretion disk.



قيم البحث

اقرأ أيضاً

NGC 7793 P13 is a variable (luminosity range ~100) ultraluminous X-ray source (ULX) proposed to host a stellar-mass black hole of less than 15 M$_{odot}$ in a binary system with orbital period of 64 d and a 18-23 M$_{odot}$ B9Ia companion. Within the EXTraS project we discovered pulsations at a period of ~0.42 s in two XMM-Newton observations of NGC 7793 P13, during which the source was detected at $L_{mathrm{X}}sim2.1times10^{39}$ and $5times10^{39}$ erg s$^{-1}$ (0.3-10 keV band). These findings unambiguously demonstrate that the compact object in NGC 7793 P13 is a neutron star accreting at super-Eddington rates. While standard accretion models face difficulties accounting for the pulsar X-ray luminosity, the presence of a multipolar magnetic field with $B$ ~ few $times$ 10$^{13}$ G close to the base of the accretion column appears to be in agreement with the properties of the system.
141 - F. Fuerst 2016
We report the detection of coherent pulsations from the ultraluminous X-ray source NGC 7793 P13. The ~0.42s nearly sinusoidal pulsations were initially discovered in broadband X-ray observations using XMM-Newton and NuSTAR taken in 2016. We subsequen tly also found pulsations in archival XMM-Newton data taken in 2013 and 2014. The significant (>>5 sigma) detection of coherent pulsations demonstrates that the compact object in P13 is a neutron star with an observed peak luminosity of ~1e40 erg/s (assuming isotropy), well above the Eddington limit for a 1.4 M_sun accretor. This makes P13 the second ultraluminous X-ray source known to be powered by an accreting neutron star. The pulse period varies between epochs, with a slow but persistent spin up over the 2013-2016 period. This spin-up indicates a magnetic field of B ~ 1.5e12 G, typical of many accreting pulsars. The most likely explanation for the extreme luminosity is a high degree of beaming, however this is difficult to reconcile with the sinusoidal pulse profile.
We present a detailed, broadband X-ray spectral analysis of the ULX pulsar NGC 7793 P13, a known super-Eddington source, utilizing data from the $XMM$-$Newton$, $NuSTAR$ and $Chandra$ observatories. The broadband $XMM$-$Newton+NuSTAR$ spectrum of P13 is qualitatively similar to the rest of the ULX sample with broadband coverage, suggesting that additional ULXs in the known population may host neutron star accretors. Through time-averaged, phase-resolved and multi-epoch studies, we find that two non-pulsed thermal blackbody components with temperatures $sim$0.5 and $sim$1.5 keV are required to fit the data below 10 keV, in addition to a third continuum component which extends to higher energies and is associated with the pulsed emission from the accretion column. The characteristic radii of the thermal components appear to be similar, and are too large to be associated with the neutron star itself, so the need for two components likely indicates the accretion flow outside the magnetosphere is complex. We suggest a scenario in which the thick inner disc expected for super-Eddington accretion begins to form, but is terminated by the neutron stars magnetic field soon after its onset, implying a limit of $B lesssim 6 times 10^{12}$ G for the dipolar component of the central neutron stars magnetic field. Evidence of similar termination of the disc in other sources may offer a further means of identifying additional neutron star ULXs. Finally, we examine the spectrum exhibited by P13 during one of its unusual off states. These data require both a hard powerlaw component, suggesting residual accretion onto the neutron star, and emission from a thermal plasma, which we argue is likely associated with the P13 system.
116 - V. Jithesh 2017
We investigate the long-term spectral variability in the ultra-luminous X-ray source Holmberg IX X--1. By analyzing the data from eight {it Suzaku} and 13 {it XMM-Newton} observations conducted between 2001 and 2015, we perform a detailed spectral mo deling for all spectra with simple models and complex physical models. We find that the spectra can be well explained by a disc plus thermal Comptonization model. Applying this model, we unveil correlations between the X-ray luminosity ($L_{rm X}$) and the spectral parameters. Among the correlations, a particular one is the statistically significant positive correlation between $L_{rm X}$ and the photon index ($Gamma$), while at the high luminosities of $> 2times10^{40},{rm~erg s}^{-1}$, the source becomes marginally hard and that results a change in the slope of the $Gamma - L_{rm X}$ correlation. Similar variability behavior is observed in the optical depth of the source around $L_{rm X} sim 2times10^{40},{rm~erg s}^{-1}$ as the source becomes more optically thick. We consider the scenario that a corona covers the inner part of the disc, and the correlations can be explained as to be driven by the variability of seed photons from the disc input into the corona. On the basis of the disc-corona model, we discuss the physical processes that are possibly indicated by the variability of the spectral parameters. Our analysis reveals the complex variability behavior of Holmberg IX X--1 and the variability mechanism is likely related to the geometry of the X-ray emitting regions.
89 - F. Fuerst 2018
We present a timing analysis of multiple XMM-Newton and NuSTAR observations of the ultra-luminous pulsar NGC 7793 P13 spread over its 65d variability period. We use the measured pulse periods to determine the orbital ephemeris, confirm a long orbital period with P_orb = 63.9 (+0.5,-0.6) d, and find an eccentricity of e <= 0.15. The orbital signature is imprinted on top of a secular spin-up, which seems to get faster as the source becomes brighter. We also analyse data from dense monitoring of the source with Swift and find an optical photometric period of 63.9 +/- 0.5 d and an X-ray flux period of 66.8 +/- 0.4 d. The optical period is consistent with the orbital period, while the X-ray flux period is significantly longer. We discuss possible reasons for this discrepancy, which could be due to a super-orbital period caused by a precessing accretion disk or an orbital resonance. We put the orbital period of P13 into context with the orbital periods implied for two other ultra-luminous pulsars, M82 X-2 and NGC 5907 ULX and discuss possible implications for the system parameters.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا