Exploring Sub-MeV Sensitivity of AstroSat-CZTI for ON-axis Bright Sources

376   0   0.0 ( 0 )
 نشر من قبل Abhay Kumar
 تاريخ النشر 2021
  مجال البحث فيزياء
والبحث باللغة English
 تأليف Abhay Kumar




اسأل ChatGPT حول البحث

The Cadmium Zinc Telluride Imager (CZTI) onboard AstroSat is designed for hard X-ray imaging and spectroscopy in the energy range of 20 - 100 keV. The CZT detectors are of 5 mm thickness and hence have good efficiency for Compton interactions beyond 100 keV. The polarisation analysis using CZTI relies on such Compton events and have been verified experimentally. The same Compton events can also be used to extend the spectroscopy up to 380 keV. Further, it has been observed that about 20% pixels of the CZTI detector plane have low gain, and they are excluded from the primary spectroscopy. If these pixels are included, then the spectroscopic capability of CZTI can be extended up to 500 keV and further up to 700 keV with a better gain calibration in the future. Here we explore the possibility of using the Compton events as well as the low gain pixels to extend the spectroscopic energy range of CZTI for ON-axis bright X-ray sources. We demonstrate this technique using Crab observations and explore its sensitivity.



قيم البحث

اقرأ أيضاً

Cadmium-Zinc-Telluride Imager (CZTI) is one of the five payloads on-board recently launched Indian astronomy satellite AstroSat. CZTI is primarily designed for simultaneous hard X-ray imaging and spectroscopy of celestial X-ray sources. It employs th e technique of coded mask imaging for measuring spectra in the energy range of 20 - 150 keV. It was the first scientific payload of AstroSat to be switched on after one week of the launch and was made operational during the subsequent week. Here we present preliminary results from the performance verification phase observations and discuss the in-orbit performance of CZTI.
AstroSat is Indias first space-based astronomical observatory, launched on September 28, 2015. One of the payloads aboard AstroSat is the Cadmium Zinc Telluride Imager (CZTI), operating at hard X-rays. CZTI employs a two-dimensional coded aperture ma sk for the purpose of imaging. In this paper, we discuss various image reconstruction algorithms adopted for the test and calibration of the imaging capability of CZTI and present results from CZTI on-ground as well as in-orbit image calibration.
We present a machine learning (ML) based method for automated detection of Gamma-Ray Burst (GRB) candidate events in the range 60 keV - 250 keV from the AstroSat Cadmium Zinc Telluride Imager data. We use density-based spatial clustering to detect ex cess power and carry out an unsupervised hierarchical clustering across all such events to identify the different light curves present in the data. This representation helps understand the instruments sensitivity to the various GRB populations and identify the major non-astrophysical noise artefacts present in the data. We use Dynamic Time Warping (DTW) to carry out template matching, which ensures the morphological similarity of the detected events with known typical GRB light curves. DTW alleviates the need for a dense template repository often required in matched filtering like searches. The use of a similarity metric facilitates outlier detection suitable for capturing previously unmodelled events. We briefly discuss the characteristics of 35 long GRB candidates detected using the pipeline and show that with minor modifications such as adaptive binning, the method is also sensitive to short GRB events. Augmenting the existing data analysis pipeline with such ML capabilities alleviates the need for extensive manual inspection, enabling quicker response to alerts received from other observatories such as the gravitational-wave detectors.
The radio as well as the high energy emission mechanism in pulsars is yet not understood properly. A multi-wavelength study is likely to help in better understanding of such processes. The first Indian space-based observatory, ASTROSAT, has five inst ruments aboard, which cover the electromagnetic spectrum from infra-red (1300 $AA$) to hard X-ray (380 KeV). Cadmium Zinc Telluride Imager (CZTI), one of the five instruments is a hard X-ray telescope functional over an energy range of 20-380 KeV. We aim to estimate the timing offset introduced in the data acquisition pipeline of the instrument, which will help in time alignment of high energy time series with those from two other ground-based observatories, viz. the Giant Meterwave Radio Telescope (GMRT) and the Ooty Radio Telescope (ORT). PSR B0531+21 is a well-studied pulsar with nearly aligned radio and hard X-ray pulse profiles. We use simultaneous observations of this pulsar with the ASTROSAT, the ORT and the GMRT. The pulsar was especially observed using the ORT with almost daily cadence to obtain good timing solutions. We also supplement the ORT data with archival FERMI data for estimation of timing noise. The timing offset of ASTROSAT instruments was estimated from fits to arrival time data at the ASTROSAT and the radio observatories. We estimate the offset between the GMRT and the ASTROSAT-CZTI to be -4716 $pm$ 50 $mu s$. The corresponding offset with the ORT was -29639 $pm$ 50 $mu s$. The offsets between the GMRT and Fermi-LAT -5368 $pm$ 56 $mu s$. (Abridged)
Cadmium Zinc Telluride Imager (CZTI) onboard AstroSat has been a prolific Gamma-Ray Burst (GRB) monitor. While the 2-pixel Compton scattered events (100 - 300 keV) are used to extract sensitive spectroscopic information, the inclusion of the low-gain pixels (around 20% of the detector plane) after careful calibration extends the energy range of Compton energy spectra to 600 keV. The new feature also allows single-pixel spectroscopy of the GRBs to the sub-MeV range which is otherwise limited to 150 keV. We also introduced a new noise rejection algorithm in the analysis (Compton noise). These new additions not only enhances the spectroscopic sensitivity of CZTI, but the sub-MeV spectroscopy will also allow proper characterization of the GRBs not detected by Fermi. This article describes the methodology of single, Compton event and veto spectroscopy in 100 - 600 keV for the GRBs detected in the first year of operation. CZTI in last five years has detected around 20 bright GRBs. The new methodologies, when applied on the spectral analysis for this large sample of GRBs, has the potential to improve the results significantly and help in better understanding the prompt emission mechanism.