We have developed prototypes of GEM-like detectors with resistive electrodes to be used as RICH photodetectors equipped with CsI photocathodes. The main advantages of these detectors are their intrinsic spark protection and possibility to operate at high gain (~10E5) in many gases including poorly quenched ones, allowing for the adoption of windowless configurations in which the radiator gas is also used in the chamber. Results of systematic studies of the resistive GEMs combined with CsI photocathodes are presented: its quantum efficiency, rate characteristics, long-term stability, etc. On the basis of the obtained results, we believe that the new detector will be a promising candidate for upgrading the ALICE RICH detector



قيم البحث

اقرأ أيضاً

The paper summarizes our latest progress in the development of newly introduced micro pattern gaseous detectors with resistive electrodes. These resistive electrodes protect the detector and the front-end electronics in case of occasional discharges and thus make the detectors very robust and reliable in operation. As an example, we describe in greater detail a new recently developed GEM-like detector, fully spark-protected with electrodes made of resistive kapton. We discovered that all resistive layers used in these studies (including kapton), that are coated with photosensitive layers, such as CsI, can be used as efficient photo cathodes for detectors operating in a pulse counting mode. We describe the first applications of such detectors combined with CsI or SbCs photo cathodes for the detection of UV photons at room and cryogenic temperatures.
The first successful attempts to optimize the electric field in Resistive Microstrip Gas Chamber (RMSGC) using additional field shaping strips located inside the detector substrate are described.
For precise start time determination a Beam Fragmentation T$_0$ Counter (BFTC) is under development for the Time-of-Flight Wall of the Compressed Baryonic Matter Spectrometer (CBM) at the Facility for Antiproton and Ion Research (FAIR) at Darmstadt/G ermany. This detector will be located around the beam pipe, covering the front area of the Projectile Spectator Detector. The fluxes at this region are expected to exceed 10$^5$cm$^{-2}$s$^{-1}$. Resistive plate chambers (RPC) with ceramic composite electrodes could be use because of their high rate capabilities and radiation hardness of material. Efficiency $ge$ 97%, time resolution $le$ 90 ps and rate capability $ge$ 10$^5$cm$^{-2}$s$^{-1}$ were confirmed during many tests with high beam fluxes of relativistic electrons. We confirm the stability of these characteristics with low resistive Si$_3$N$_4$/SiC floating electrodes for a prototype of eight small RPCs, where each of them contains six gas gaps. The active RPC size amounts 20$times$20 mm$^2$ produced on basis of Al$_3$O$_2$ and Si$_3$N$_4$/SiC ceramics. Recent test results obtained with relativistic electrons at the linear accelerator ELBE of the Helmholtz-Zentrum Dresden-Rossendorf with new PADI-10 Front-end electronic will be presented.
In this study we present first results from a new detector of UV photons: a thick gaseous electron multiplier (GEM) with resistive electrodes, combined with CsI or CsTe/CsI photocathodes. The hole type structure considerably suppresses the photon and ion feedback, whereas the resistive electrodes protect the detector and the readout electronics from damage by any eventual discharges. This device reaches higher gains than a previously developed photosensitive RPC and could be used not only for the imaging of UV sources, flames or Cherenkov light, for example, but also for the detection of X-rays and charged particles.
Characteristics of triple GEM detector have been studied systematically. The variation of the effective gain and energy resolution of GEM with variation of the applied voltage has been measured with Fe55 X-ray source for different gas mixtures and wi th different gas flow rates. Long-term test of the GEM has also been performed.