ترغب بنشر مسار تعليمي؟ اضغط هنا

High precision atom interferometry in a microgravity environment

176   0   0.0 ( 0 )
 نشر من قبل Boris Dubetsky
 تاريخ النشر 1999
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

We propose a set of experiments in which Ramsey-fringe techniques are tailored to probe transitions originating and terminating on the same ground state level. When pulses of resonant radiation, separated by a time delay $% T, $ interact with atoms, it is possible to produce Ramsey fringes having widths of order 1/T. If each pulse contains two counterpropagating travelling wave modes, the atomic wave function is split into two or more components having different center-of-mass momenta. Matter-wave interference of these components leads to atomic gratings, which have been observed in both spatially separated fields and time separated fields. Time-dependent signals can be transformed into frequency dependent signals, leading to ground state Ramsey fringes (GSRF). The signals can be used to probe many problems of fundamental importance: a precise measurement of the earth gravitational acceleration $g$ and residual gravity in a microgravity environment with an accuracy $6 10^{-9}g;$ the rotation rate measurement with an accuracy of 6 10^{-3} deg/h; the recoil frequency measurement. Since only transitions originating and terminating on the same ground state are involved, frequency measurements can be carried out using lasers phase-locked by quartz oscillators having relatively low frequency. Our technique may allow one to increase the precision by a factor of 100 (the rf- to quartz oscillator frequencies ratio) over previous experiments based on Raman-Ramsey fringes or reduce on the same factor requirements for frequency stabilization.



قيم البحث

اقرأ أيضاً

We present a modular rack-mounted laser system for the cooling and manipulation of neutral rubidium atoms which has been developed for a portable gravimeter based on atom interferometry that will be capable of performing high precision gravity measur ements directly at sites of geophysical interest. This laser system is constructed in a compact and mobile design so that it can be transported to different locations, yet it still offers improvements over many conventional laboratory-based laser systems. Our system is contained in a standard 19 rack and emits light at five different frequencies simultaneously on up to 12 fibre ports at a total output power of 800 mW. These frequencies can be changed and switched between ports in less than a microsecond. The setup includes two phase-locked diode lasers with a phase noise spectral density of less than 1 mu rad/sqrt(Hz) in the frequency range in which our gravimeter is most sensitive to noise. We characterize this laser system and evaluate the performance limits it imposes on an interferometer.
129 - Guillaume Stern 2009
We describe the operation of a light pulse interferometer using cold 87Rb atoms in reduced gravity. Using a series of two Raman transitions induced by light pulses, we have obtained Ramsey fringes in the low gravity environment achieved during parabo lic flights. With our compact apparatus, we have operated in a regime which is not accessible on ground. In the much lower gravity environment and lower vibration level of a satellite, our cold atom interferometer could measure accelerations with a sensitivity orders of magnitude better than the best ground based accelerometers and close to proven spaced-based ones.
We propose a new scheme for an improved determination of the Newtonian gravitational constant G and evaluate it by numerical simulations. Cold atoms in free fall are probed by atom interferometry measurements to characterize the gravitational field g enerated by external source masses. Two source mass configurations having different geometry and using different materials are compared to identify an optimized experimental setup for the G measurement. The effects of the magnetic fields used to manipulate the atoms and to control the interferometer phase are also characterized.
472 - Robin Corgier 2020
We present a source engineering concept for a binary quantum mixture suitable as input for differential, precision atom interferometry with drift times of several seconds. To solve the non-linear dynamics of the mixture, we develop a set of scaling a pproach equations and verify their validity contrasting it to the one of a system of coupled Gross-Pitaevskii equations. This scaling approach is a generalization of the standard approach commonly used for single species. Its validity range is discussed with respect to intra- and inter-species interaction regimes. We propose a multi-stage, non-linear atomic lens sequence to simultaneously create dual ensembles with ultra-slow kinetic expansion energies, below 15 pK. Our scheme has the advantage of mitigating wave front aberrations, a leading systematic effect in precision atom interferometry.
Atom interferometers covering macroscopic domains of space-time are a spectacular manifestation of the wave nature of matter. Due to their unique coherence properties, Bose-Einstein condensates are ideal sources for an atom interferometer in extended free fall. In this paper we report on the realization of an asymmetric Mach-Zehnder interferometer operated with a Bose-Einstein condensate in microgravity. The resulting interference pattern is similar to the one in the far-field of a double-slit and shows a linear scaling with the time the wave packets expand. We employ delta-kick cooling in order to enhance the signal and extend our atom interferometer. Our experiments demonstrate the high potential of interferometers operated with quantum gases for probing the fundamental concepts of quantum mechanics and general relativity.