ترغب بنشر مسار تعليمي؟ اضغط هنا

Loading a vapor cell magneto-optic trap using light-induced atom desorption

58   0   0.0 ( 0 )
 نشر من قبل Brian P. Anderson
 تاريخ النشر 2000
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

Low intensity white light was used to increase the loading rate of $^{87}$Rb atoms into a vapor cell magneto-optic trap by inducing non-thermal desorption of Rb atoms from the stainless steel walls of the vapor cell. An increased Rb partial pressure reached a new equilibrium value in less than 10 seconds after switching on the broadband light source. After the source was turned off, the partial pressure returned to its previous value in $1/e$ times as short as 10 seconds.



قيم البحث

اقرأ أيضاً

Recently, we have experimentally demonstrated a continuous loading mechanism for an optical dipole trap from a guided atomic beam [1]. The observed evolution of the number of atoms and temperature in the trap are consequences of the unusual trap geom etry. In the present paper, we develop a model based on a set of rate equations to describe the loading dynamics of such a mechanism. We consider the collision statistics in the non-uniform trap potential that leads to twodimensional evaporation. The comparison between the resulting computations and experimental data allows to identify the dominant loss process and suggests ways to enhance the achievable steady-state atom number. Concerning subsequent evaporative cooling, we find that the possibility of controlling axial and radial confinement independently allows faster evaporation ramps compared to single beam optical dipole traps.
We present a versatile and compact electron beam driven source for alkali metal atoms, which can be implemented in cryostats. With a heat load of less than 10mW, the heat dissipation normalized to the atoms loaded into the magneto-optical Trap (MOT), is about a factor 1000 smaller than for a typical alkali metal dispenser. The measured linear scaling of the MOT loading rate with electron current observed in the experiments, indicates that electron stimulated desorption is the corresponding mechanism to release the atoms.
We have demonstrated that the ion current resulting from collisions between metastable krypton atoms in a magneto-optical trap can be used to precisely measure the trap loading rate. We measured both the ion current of the abundant isotope Kr-83 (iso topic abundance = 11%) and the single-atom counting rate of the rare isotope Kr-85 (isotopic abundance ~ 1x10^-11), and found the two quantities to be proportional at a precision level of 0.9%. This work results in a significant improvement in using the magneto-optical trap as an analytical tool for noble-gas isotope ratio measurements, and will benefit both atomic physics studies and applications in the earth sciences.
The loading dynamics of an alkali-atom magneto-optical trap can be used as a reliable measure of vacuum pressure, with loading time T indicating a pressure less than or equal to [2x10^(-8) Torr s]/T. This relation is accurate to approximately a facto r of two over wide variations in trap parameters, background gas composition, or trapped alkali species. The low-pressure limit of the method does depend on the trap parameters, but typically extends to the 10^(-10) Torr range.
139 - S. Pradhan , S. Mishra , R. Behera 2014
The operation of a high sensitive atomic magnetometer using resonant elliptically polarized light is demonstrated. The experimental geometry allows autonomous frequency stabilization of the laser, thereby offers compact operation of the overall devic e. The magnetometry is based on measurement of the zero magnetic field resonance in degenerate two level system using polarimetric detection and has a preliminary sensitivity of <10 pT/Hz1/2 @ 1 Hz.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا