In dual-energy computed tomography (DECT), low- and high- kVp data are collected often over a full-angular range (FAR) of $360^circ$. While there exists strong interest in DECT with low- and high-kVp data acquired over limited-angular ranges (LARs), there remains little investigation of image reconstruction in DECT with LAR data. Objective: We investigate image reconstruction with minimized LAR artifacts from low- and high-kVp data over LARs of $le 180^circ$ by using a directional-total-variation (DTV) algorithm. Methods: Image reconstruction from LAR data is formulated as a convex optimization problem in which data-$ell_2$ is minimized with constraints on images DTVs along orthogonal axes. We then achieve image reconstruction by applying the DTV algorithm to solve the optimization problem. We conduct numerical studies from data generated over arcs of LARs, ranging from $14^circ$ to $180^circ$, and perform visual inspection and quantitative analysis of images reconstructed. Results: Monochromatic images of interest obtained with the DTV algorithm from LAR data show substantially reduced artifacts that are observed often in images obtained with existing algorithms. The improved image quality also leads to accurate estimation of physical quantities of interest, such as effective atomic number and iodine-contrast concentration. Conclusion: Our study reveals that from LAR data of low- and high-kVp, monochromatic images can be obtained that are visually, and physical quantities can be estimated that are quantitatively, comparable to those obtained in FAR DECT. Significance: As LAR DECT is of high practical application interest, the results acquired in the work may engender insights into the design of DECT with LAR scanning configurations of practical application significance.
In a standard computed tomography (CT) image, pixels having the same Hounsfield Units (HU) can correspond to different materials and it is, therefore, challenging to differentiate and quantify materials. Dual-energy CT (DECT) is desirable to differen
Investigation of image reconstruction from data collected over a limited angular range in X-ray CT remains a topic of active research because it may yield insight into the development of imaging workflow of practical significance. This reconstruction
Purpose: Dual-energy CT (DECT) has been shown to derive stopping power ratio (SPR) map with higher accuracy than conventional single energy CT (SECT) by obtaining the energy dependence of photon interactions. However, DECT is not as widely implemente
Purpose: Dual-energy CT (DECT) has been used to derive relative stopping power (RSP) map by obtaining the energy dependence of photon interactions. The DECT-derived RSP maps could potentially be compromised by image noise levels and the severity of a
Increased noise is a general concern for dual-energy material decomposition. Here, we develop an image-domain material decomposition algorithm for dual-energy CT (DECT) by incorporating an edge-preserving filter into the Local HighlY constrained back