Improving spatial resolution of scanning SQUID microscopy with an on-chip design

146   0   0.0 ( 0 )
 نشر من قبل Yihua Wang
 تاريخ النشر 2021
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

Scanning superconducting quantum interference device microscopy (sSQUID) is currently one of the most effective methods for direct and sensitive magnetic flux imaging on the mesoscopic scale. A SQUID-on-chip design allows integration of field coils for susceptometry in a gradiometer setup which is very desirable for measuring magnetic responses of quantum matter. However, the spatial resolution of such a design has largely been limited to micrometers due to the difficulty in approaching the sample. Here, we used electron beam lithography technology in the fabrication of the 3D nano-bridge-based SQUID devices to prepare pick-up coils with diameters down to 150 nm. Furthermore, we integrated the deep silicon etching process in order to minimize the distance between the pick-up coil and the wafer edge. Combined with a tuning-fork-based scanning head, the sharpness of the etched chip edge enables a precision of 5 nm in height control. By scanning measurements on niobium chessboard samples using these improved SQUID devices, we demonstrate sub-micron spatial resolutions in both magnetometry and susceptometry, significantly better than our previous generations of nano-SQUIDs. Such improvement in spatial resolution of SQUID-on-chip is a valuable progress for magnetic imaging of quantum materials and devices in various modes.



قيم البحث

اقرأ أيضاً

Superconducting QUantum Interference Device (SQUID) microscopy has excellent magnetic field sensitivity, but suffers from modest spatial resolution when compared with other scanning probes. This spatial resolution is determined by both the size of th e field sensitive area and the spacing between this area and the sample surface. In this paper we describe scanning SQUID susceptometers that achieve sub-micron spatial resolution while retaining a white noise floor flux sensitivity of $approx 2muPhi_0/Hz^{1/2}$. This high spatial resolution is accomplished by deep sub-micron feature sizes, well shielded pickup loops fabricated using a planarized process, and a deep etch step that minimizes the spacing between the sample surface and the SQUID pickup loop. We describe the design, modeling, fabrication, and testing of these sensors. Although sub-micron spatial resolution has been achieved previously in scanning SQUID sensors, our sensors not only achieve high spatial resolution, but also have integrated modulation coils for flux feedback, integrated field coils for susceptibility measurements, and batch processing. They are therefore a generally applicable tool for imaging sample magnetization, currents, and susceptibilities with higher spatial resolution than previous susceptometers.
155 - P. Tovee , M. Pumarol , D. Zeze 2011
Scanning Thermal Microscopy (SThM) uses micromachined thermal sensors integrated in a force sensing cantilever with a nanoscale tip can be highly useful for exploration of thermal management of nanoscale semiconductor devices. As well as mapping of s urface properties of related materials. Whereas SThM is capable to image externally generated heat with nanoscale resolution, its ability to map and measure thermal conductivity of materials has been mainly limited to polymers or similar materials possessing low thermal conductivity in the range from 0.1 to 1 W/mK, with lateral resolution on the order of 1 mum. In this paper we use linked experimental and theoretical approaches to analyse thermal performance and sensitivity of the micromachined SThM probes in order to expand their applicability to a broader range of nanostructures from polymers to semiconductors and metals. We develop physical models of interlinked thermal and electrical phenomena in these probes and then validate these models using experimental measurements of the real probes, which provided the basis for analysing SThM performance in exploration of nanostructures. Our study then highlights critical features of these probes, namely, the geometrical location of the thermal sensor with respect to the probe apex, thermal conductance of the probe to the support base, heat conduction to the surrounding gas, and the thermal conductivity of tip material adjacent to the apex. It is furthermore allows us to propose a novel design of the SThM probe that incorporates a carbon nanotube (CNT) or similar high thermal conductivity graphene sheet material positioned near the probe apex. The new sensor is predicted to provide spatial resolution to the thermal properties of nanostructures on the order of few tens of nm, as well as to expand the sensitivity of the SThM probe to materials with heat conductivity values up to 100-1000 W/mK.
We present scanning tunneling microscopy (STM) images of single-layer graphene crystals examined under ultrahigh vacuum conditions. The samples, with lateral dimensions on the micron scale, were prepared on a silicon dioxide surface by direct exfolia tion of single crystal graphite. The single-layer films were identified using Raman spectroscopy. Topographic images of single-layer samples display the honeycomb structure expected for the full hexagonal symmetry of an isolated graphene monolayer. The absence of observable defects in the STM images is indicative of the high quality of these films. Crystals comprised of a few layers of graphene were also examined. They exhibited dramatically different STM topography, displaying the reduced three-fold symmetry characteristic of the surface of bulk graphite.
71 - G. Yue , L. Chen , J. Barreda 2017
Precise detection of spin resonance is of paramount importance to achieve coherent spin control in quantum computing. We present a novel setup for spin resonance measurements, which uses a dc-SQUID flux detector coupled to an antenna from a coplanar waveguide. The SQUID and the waveguide are fabricated from 20~nm Nb thin film, allowing high magnetic field operation with the field applied parallel to the chip. We observe a resonance signal between the first and third excited states of Gd spins $S=7/2$ in a CaWO$_4$ crystal, relevant for state control in multi-level systems.
Scanning superconducting quantum interference device microscopy (SSM) is a scanning probe technique that images local magnetic flux, which allows for mapping of magnetic fields with high field and spatial accuracy. Many studies involving SSM have bee n published in the last decades, using SSM to make qualitative statements about magnetism. However, quantitative analysis using SSM has received less attention. In this work, we discuss several aspects of interpreting SSM images and methods to improve quantitative analysis. First, we analyse the spatial resolution and how it depends on several factors. Second, we discuss the analysis of SSM scans and the information obtained from the SSM data. Using simulations, we show how signals evolve as a function of changing scan height, SQUID loop size, magnetization strength and orientation. We also investigated 2-dimensional autocorrelation analysis to extract information about the size, shape and symmetry of magnetic features. Finally, we provide an outlook on possible future applications and improvements.