ترغب بنشر مسار تعليمي؟ اضغط هنا

The S$pi$RIT Time Projection Chamber

120   0   0.0 ( 0 )
 نشر من قبل Jonathan Barney
 تاريخ النشر 2020
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

The SAMURAI Pion Reconstruction and Ion-Tracker Time Projection Chamber (S$pi$RIT TPC) was designed to enable measurements of heavy ion collisions with the SAMURAI spectrometer at the RIKEN Radioactive Isotope Beam Factory and provide constraints on the Equation of State of neutron-rich nuclear matter. The S$pi$RIT TPC has a 50.5 cm drift length and an 86.4 cm $times$ 134.4 cm pad plane with 12,096 pads that are equipped with the Generic Electronics for TPCs readout electronics. The S$pi$RIT TPC allows excellent reconstruction of particles and provides isotopic resolution for pions and other light charged particles across a wide range of energy losses and momenta. Details of the S$pi$RIT TPC are presented, along with discussion of the TPC performance based on cosmic ray and experimental data.



قيم البحث

اقرأ أيضاً

236 - C.Y. Tsang , J. Estee , R. Wang 2019
Time projection chambers (TPCs) are widely used in nuclear and particle physics. They are particularly useful when measuring reaction products from heavy ion collisions. Most nuclear experiments at low energy are performed in a fixed target configura tion, in which the unreacted beam will pass through the detection volume. As the beam intensity increases, the buildup of positive ions created from the ionization of the detector gas by the beam creates the main source of space charge, distorting the nominal electric field of the TPC. This has a profound effect on the accuracy of the measured momenta of the emitted particles. In this paper we will discuss the magnitude of the effects and construct an observable more appropriate for fixed target experiments to study the effects. We also will present an algorithm for correcting the space charge and some of the implications it has on the momentum determination.
197 - J.W. Lee , G. Jhang , G. Cerizza 2020
In this paper, we present a software framework, S$pi$RITROOT, which is capable of track reconstruction and analysis of heavy-ion collision events recorded with the S$pi$RIT time projection chamber. The track-fitting toolkit GENFIT and the vertex reco nstruction toolkit RAVE are applied to a box-type detector system. A pattern recognition algorithm which performs helix track finding and handles overlapping pulses is described. The performance of the software is investigated using experimental data obtained at the Radioactive Isotope Beam Facility (RIBF) at RIKEN. This work focuses on data from $^{132}$Sn + $^{124}$Sn collision events with beam energy of 270 AMeV. Particle identification is established using $left<dE/dxright>$ and magnetic rigidity, with pions, hydrogen isotopes, and helium isotopes.
130 - R. Shane , A. McIntosh , T. Isobe 2014
A Time-Projection Chamber (TPC) called the SAMURAI Pion-Reconstruction and Ion-Tracker (S$pi$RIT) has recently been constructed at Michigan State University as part of an international effort to constrain the symmetry-energy term in the nuclear Equat ion of State (EoS). The S$pi$RIT TPC will be used in conjunction with the SAMURAI spectrometer at the Radioactive Isotope Beam Factory (RIBF) at RIKEN to measure yield ratios for pions and other light isospin multiplets produced in central collisions of neutron-rich heavy ions, such as $^{132}$Sn + $^{124}$Sn. The S$pi$RIT TPC can function both as a TPC detector and as an active target. It has a vertical drift length of 50 cm, parallel to the magnetic field. Gas multiplication is achieved through the use of a multi-wire anode. Image charges are produced in the 12096 pads, and are read out with the recently developed Generic Electronics for TPCs.
KATANA - the Krakow Array for Triggering with Amplitude discrimiNAtion - has been built and used as a trigger and veto detector for the S$pi$RIT TPC at RIKEN. Its construction allows operating in magnetic field and providing fast response for ionizin g particles, giving the approximate forward multiplicity and charge information. Depending on this information, trigger and veto signals are generated. The article presents performance of the detector and details of its construction. A simple phenomenological parametrization of the number of emitted scintillation photons in plastic scintillator is proposed. The effect of the light output deterioration in the plastic scintillator due to the in-beam irradiation is discussed.
The MuCap experiment at the Paul Scherrer Institute performed a high-precision measurement of the rate of the basic electroweak process of nuclear muon capture by the proton, $mu^- + p rightarrow n + u_mu$. The experimental approach was based on the use of a time projection chamber (TPC) that operated in pure hydrogen gas at a pressure of 10 bar and functioned as an active muon stopping target. The TPC detected the tracks of individual muon arrivals in three dimensions, while the trajectories of outgoing decay (Michel) electrons were measured by two surrounding wire chambers and a plastic scintillation hodoscope. The muon and electron detectors together enabled a precise measurement of the $mu p$ atoms lifetime, from which the nuclear muon capture rate was deduced. The TPC was also used to monitor the purity of the hydrogen gas by detecting the nuclear recoils that follow muon capture by elemental impurities. This paper describes the TPC design and performance in detail.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا