ترغب بنشر مسار تعليمي؟ اضغط هنا

Spectral Characterization of a Microbolometer Focal Plane Array at Terahertz Frequencies

223   0   0.0 ( 0 )
 نشر من قبل Ki-Yong Kim
 تاريخ النشر 2018
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

We have developed a method to characterize the spectral response of an uncooled microbolometer focal plane array at a broad range of terahertz (THz) frequencies (4~50 THz). This is achieved by using a spectrum-tailored blackbody radiator as a broadband THz source and measuring its spectral power with a Fourier transform infrared (FTIR) interferometer. With an additional measurement with a pyroelectric detector as a reference, the spectral response of the microbolometer relative to the pyroelectric reference is obtained with a signal-to-noise ratio of 100 over a >50 THz bandwidth.



قيم البحث

اقرأ أيضاً

The Extended Analogue Silicon Photo-multiplier Integrated Read Out Chip, EASIROC, is a chip proposed as front-end of the camera at the focal plane of the imaging Cherenkov ASTRI SST-2M telescope prototype. This paper presents the results of the measu rements performed to characterize EASIROC in order to evaluate its compliance with the ASTRI SST-2M focal plane requirements. In particular, we investigated the trigger time walk and the jitter effects as a function of the pulse amplitude. The EASIROC output signal is found to vary linearly as a function of the input pulse amplitude with very low level of electronic noise and cross-talk (<1%). Our results show that it is suitable as front-end chip for the camera prototype, although, specific modifications are necessary to adopt the device in the final version of the telescope.
127 - I. Mateos , B. Patton , E. Zhivun 2015
Noise measurements have been carried out in the LISA bandwidth (0.1 mHz to 100 mHz) to characterize an all-optical atomic magnetometer based on nonlinear magneto-optical rotation. This was done in order to assess if the technology can be used for spa ce missions with demanding low-frequency requirements like the LISA concept. Magnetometry for low-frequency applications is usually limited by $1/f$ noise and thermal drifts, which become the dominant contributions at sub-millihertz frequencies. Magnetic field measurements with atomic magnetometers are not immune to low-frequency fluctuations and significant excess noise may arise due to external elements, such as temperature fluctuations or intrinsic noise in the electronics. In addition, low-frequency drifts in the applied magnetic field have been identified in order to distinguish their noise contribution from that of the sensor. We have found the technology suitable for LISA in terms of sensitivity, although further work must be done to characterize the low-frequency noise in a miniaturized setup suitable for space missions.
MAGIX is a planned experiment that will be implemented at the upcoming accelerator MESA in Mainz. Due to its location in the energy-recovering lane of the accelerator beam-currents up to 1mA with a maximum energy of 105 MeV will be available for prec ision experiments. MAGIX itself consists of a jet-target and two magnetic spectrometers. Inside the spectrometers GEM-based detectors will be used in the focal plane for track reconstruction. The design goals for the detector modules are a spatial resolution of 50 um, a size of 1.20 m x 0.3 m and a minimal material budget. To accomplish these goals we started developing several GEM-prototypes to study different behaviors and techniques to optimize the final detector design. The GEM foils used are provided by CERN and are trained, stretched and framed in our laboratory. The readout is done with an SRS based system. In this contribution the requirements, achievements and the ongoing developments are presented.
The focal-plane detector system for the KArlsruhe TRItium Neutrino (KATRIN) experiment consists of a multi-pixel silicon p-i-n-diode array, custom readout electronics, two superconducting solenoid magnets, an ultra high-vacuum system, a high-vacuum s ystem, calibration and monitoring devices, a scintillating veto, and a custom data-acquisition system. It is designed to detect the low-energy electrons selected by the KATRIN main spectrometer. We describe the system and summarize its performance after its final installation.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا