ترغب بنشر مسار تعليمي؟ اضغط هنا

From Relativistic Electrons To X-Ray Phase Contrast Imaging

112   0   0.0 ( 0 )
 نشر من قبل Lumpkin, Alex H.
 تاريخ النشر 2018
  مجال البحث فيزياء
والبحث باللغة English
 تأليف A.H. Lumpkin




اسأل ChatGPT حول البحث

We report the initial demonstrations of the use of single crystals in indirect x-ray imaging for x-ray phase contrast imaging at the Washington University in St. Louis Computational Bioimaging Laboratory (CBL). Based on single Gaussian peak fits to the x-ray images, we observed a four times smaller system point spread function (21 {mu}m (FWHM)) with the 25-mm diameter single crystals than the reference polycrystalline phosphors 80-{mu}m value. Potential fiber-optic plate depth-of-focus aspects and 33-{mu}m diameter carbon fiber imaging are also addressed.



قيم البحث

اقرأ أيضاً

X-ray phase-contrast imaging (XPCI) is a versatile technique with wide-ranging applications, particularly in the fields of biology and medicine. Where X-ray absorption radiography requires high density ratios for effective imaging, XPCI is more sensi tive to the density gradients inside a material. In this letter, we apply XPCI to the study of laser-driven shockc waves. We used two laser beams from the Petawatt High-Energy Laser for Heavy Ion EXperiments (PHELIX) at GSI: one to launch a shock wave and the other to generate an X-ray source for XPCI. Our results suggest that this technique is suitable for the study of warm dense matter (WDM), inertial confinement fusion (ICF) and laboratory astrophysics.
Currently, dual-energy X-ray phase contrast imaging is usually conducted with an X-ray Talbot-Lau interferometer. However, in this system, the two adopted energy spectra have to be chosen carefully in order to match well with the phase grating. For e xample, the accelerating voltages of the X-ray tube are supposed to be respectively set as 40 kV and 70 kV, with other energy spectra being practically unusable for dual energy imaging. This system thus has low flexibility and maneuverability in practical applications. In this work, dual energy X-ray phase-contrast imaging is performed in a grating-based non-interferometric imaging system rather than in a Talbot-Lau interferometer. The advantage of this system is that, theoretically speaking, any two separated energy spectra can be utilized to perform dual energy X-ray phase-contrast imaging. The preliminary experimental results show that dual-energy X-ray phase contrast imaging is successfully performed when the accelerating voltages of the X-ray tube are successively set as 40 kV and 50 kV. Our work increases the flexibility and maneuverability when employing dual-energy X-ray phase-contrast imaging in medical diagnoses and nondestructive tests.
114 - S. Kneip , C. McGuffey , F. Dollar 2011
Since their discovery in 1896, x-rays have had a profound impact on science, medicine and technology. Here we show that the x-rays from a novel tabletop source of bright coherent synchrotron radiation can be applied to phase contrast imaging of biolo gical specimens, yielding superior image quality and avoiding the need for scarce or expensive conventional sources.
Development of x-ray phase contrast imaging applications with a laboratory scale source have been limited by the long exposure time needed to obtain one image. We demonstrate, using the Betatron x-ray radiation produced when electrons are accelerated and wiggled in the laser-wakefield cavity, that a high quality phase contrast image of a complex object (here, a bee), located in air, can be obtained with a single laser shot. The Betatron x-ray source used in this proof of principle experiment has a source diameter of 1.7 microns and produces a synchrotron spectrum with critical energy E_c=12.3 +- 2.5 keV and 10^9 photons per shot in the whole spectrum.
Using higher-order coherence of thermal light sources, the resolution power of standard x-ray imaging techniques can be enhanced. In this work, we applied the higher-order measurement to far-field x-ray diffraction and near-field phase contrast imagi ng (PCI), in order to achieve superresolution in x-ray diffraction and obtain enhanced intensity contrast in PCI. The cost of implementing such schemes is minimal compared to the methods that achieve similar effects by using entangled x-ray photon pairs.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا