ترغب بنشر مسار تعليمي؟ اضغط هنا

Intensity interferometry with more than two detectors?

138   0   0.0 ( 0 )
 نشر من قبل Vinay Malvimat
 تاريخ النشر 2013
  مجال البحث فيزياء
والبحث باللغة English
 تأليف Vinay Malvimat




اسأل ChatGPT حول البحث

The original intensity interferometers were instruments built in the 1950s and 60s by Hanbury Brown and collaborators, achieving milli-arcsec resolutions in visible light without optical-quality mirrors. They exploited a then-novel physical effect, now known as HBT correlation after the experiments of Hanbury Brown and Twiss, and nowadays considered fundamental in quantum optics. Now a new generation of inten- sity interferometers is being designed, raising the possibility of measuring intensity correlations with three or more detectors. Quantum optics predicts some interesting features in higher-order HBT. One is that HBT correlation increases combinatorially with the number of detectors. Signal to noise considerations suggest, that many-detector HBT correlations would be mea- surable for bright masers, but very difficult for thermal sources. But the more modest three-detector HBT correlation seems measurable for bright stars, and would provide image information (namely the bispectrum) not present in standard HBT.



قيم البحث

اقرأ أيضاً

Entanglement has long stood as one of the characteristic features of quantum mechanics, yet recent developments have emphasized the importance of quantumness beyond entanglement for quantum foundations and technologies. We demonstrate that entangleme nt cannot entirely capture the worst-case sensitivity in quantum interferometry, when quantum probes are used to estimate the phase imprinted by a Hamiltonian, with fixed energy levels but variable eigenbasis, acting on one arm of an interferometer. This is shown by defining a bipartite entanglement monotone tailored to this interferometric setting and proving that it never exceeds the so-called interferometric power, a quantity which relies on more general quantum correlations beyond entanglement and captures the relevant resource. We then prove that the interferometric power can never increase when local commutativity-preserving operations are applied to qubit probes, an important step to validate such a quantity as a genuine quantum correlations monotone. These findings are accompanied by a room-temperature nuclear magnetic resonance experimental investigation, in which two-qubit states with extremal (maximal and minimal) interferometric power at fixed entanglement are produced and characterized.
Since a number of years our group is engaged in the design, construction and operation of instruments with very high time resolution in the optical band for applications to Quantum Astronomy and more conventional Astrophysics. Two instruments were bu ilt to perform photon counting with sub-nanosecond temporal accuracy. The first of the two, Aqueye+, is regularly mounted at the 1.8 m Copernicus telescope in Asiago, while the second one, Iqueye, was mounted at the ESO New Technology Telescope in Chile, and at the William Herschel Telescope and Telescopio Nazionale Galileo on the Roque (La Palma, Canary Islands). Both instruments deliver extraordinarily accurate results in optical pulsar timing. Recently, Iqueye was moved to Asiago to be mounted at the 1.2 m Galileo telescope to attempt, for the first time ever, experiments of optical intensity interferometry (a` la Hanbury Brown and Twiss) on a baseline of a few kilometers, together with the Copernicus telescope. This application was one of the original goals for the development of our instrumentation. To carry out these measurements, we are experimenting a new way of coupling the instruments to the telescopes, by means of moderate-aperture, low-optical-attenuation multi-mode optical fibers with a double-clad design. Fibers are housed in dedicated optical interfaces attached to the focus of another instrument of the 1.8 m telescope (Aqueye+) or to the Nasmyth focus of the 1.2 m telescope (Iqueye). This soft-mount solution has the advantage to facilitate the mounting of the photon counters, to keep them under controlled temperature and humidity conditions (reducing potential systematics related to varying ambient conditions), and to mitigate scheduling requirements. Here we will describe the first successful implementation of the Asiago intensity interferometer and future plans for improving it.
We propose a new approach, based on the Hanbury Brown and Twiss intensity interferometry, to transform a Cherenkov telescope to its equivalent optical telescope. We show that, based on the use of photonics components borrowed from quantum-optical app lications, we can recover spatial details of the observed source down to the diffraction limit of the Cherenkov telescope, set by its diameter at the mean wavelength of observation. For this, we propose to apply aperture synthesis techniques from pairwise and triple correlation of sub-pupil intensities, in order to reconstruct the image of a celestial source from its Fourier moduli and phase information, despite atmospheric turbulence. We examine the sensitivity of the method, i.e. limiting magnitude, and its implementation on existing or future high energy arrays of Cherenkov telescopes. We show that despite its poor optical quality compared to extremely large optical telescopes under construction, a Cherenkov telescope can provide diffraction limited imaging of celestial sources, in particular at the visible, down to violet wavelengths.
93 - Prasenjit Saha 2020
With the current revival of interest in astronomical intensity interferometry, it is interesting to revisit the associated theory, which was developed in the 1950s and 1960s. This paper argues that intensity interferometry can be understood as an ext ension of Fraunhofer diffraction to incoherent light. Interference patterns are still produced, but they are speckle-like and transient, changing on a time scale of $1/Delta u$ (where $Delta u$ is the frequency bandwidth) known as the coherence time. Bright fringes average less than one photon per coherence time, hence fringes change before they can be observed. But very occasionally, two or even more photons may be detected from an interference pattern within a coherence time. These rare coincident photons provide information about the underlying transient interference pattern, and hence about the source brightness distribution. Thinking in terms of transient sub-photon interference patterns makes it easy to see why intensity interferometry will have large optical-path tolerance, and be immune to atmospheric seeing. The unusual signal-to-noise properties also become evident. We illustrate the unobservable but conceptually useful transient interference patterns, and their observable correlation signal, with three simulated examples: (i) an elongated source like Achernar, (ii) a three-star system like Algol, and (iii) a crescent source that roughly mimics an exoplanet transit or perhaps the M87 black hole environment. Of these, (i) and (ii) are good targets for currently-planned setups, while (iii) is interesting to think about for the longer term.
High angular resolution observations at optical wavelengths provide valuable insights in stellar astrophysics, directly measuring fundamental stellar parameters, and probing stellar atmospheres, circumstellar disks, elongation of rapidly rotating sta rs, and pulsations of Cepheid variable stars. The angular size of most stars are of order one milli-arcsecond or less, and to spatially resolve stellar disks and features at this scale requires an optical interferometer using an array of telescopes with baselines on the order of hundreds of meters. We report on the successful implementation of a stellar intensity interferometry system developed for the four VERITAS imaging atmospheric-Cherenkov telescopes. The system was used to measure the angular diameter of the two sub-mas stars $beta$ Canis Majoris and $epsilon$ Orionis with a precision better than 5%. The system utilizes an off-line approach where starlight intensity fluctuations recorded at each telescope are correlated post-observation. The technique can be readily scaled onto tens to hundreds of telescopes, providing a capability that has proven technically challenging to current generation optical amplitude interferometry observatories. This work demonstrates the feasibility of performing astrophysical measurements with imaging atmospheric-Cherenkov telescope arrays as intensity interferometers and the promise for integrating an intensity interferometry system within future observatories such as the Cherenkov Telescope Array.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا