ترغب بنشر مسار تعليمي؟ اضغط هنا

Improved achromatization of phase mask coronagraphs using colored apodization

116   0   0.0 ( 0 )
 نشر من قبل Mamadou N'Diaye
 تاريخ النشر 2011
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

For direct imaging of exoplanets, a stellar coronagraph helps to remove the image of an observed bright star by attenuating the diffraction effects caused by the telescope aperture of diameter D. The Dual Zone Phase Mask (DZPM) coronagraph constitutes a promising concept since it theoretically offers a small inner working angle (IWA sim lambda_0/D), good achromaticity and high starlight rejection, typically reaching a 1e6 contrast at 5 lambda_0/D from the star over a spectral bandwidth Deltalambda/lambda_0 of 25% (similar to H-band). This last value proves to be encouraging for broadband imaging of young and warm Jupiter-like planets. Contrast levels higher than 1e6 are however required for the observation of older and/or less massive companions over a finite spectral bandwidth. An achromatization improvement of the DZPM coronagraph is therefore mandatory to reach such performance. In its design, the DZPM coronagraph uses a grey (or achromatic) apodization. We propose to replace it by a colored apodization to increase the performance of this coronagraphic system over a large spectral range. This innovative concept, called Colored Apodizer Phase Mask (CAPM) coronagraph, is defined with some design parameters optimized to reach the best contrast in the exoplanet search area. Once this done, we study the performance of the CAPM coronagraph in the presence of different errors to evaluate the sensitivity of our concept. A 2.5 mag contrast gain is estimated from the performance provided by the CAPM coronagraph with respect to that of the DZPM coronagraph. A 2.2e-8 intensity level at 5 lambda_0/D separation is then theoretically achieved with the CAPM coronagraph in the presence of a clear circular aperture and a 25% bandwidth. In addition, our studies show that our concept is less sensitive to low than high-order aberrations for a given value of rms wavefront errors.



قيم البحث

اقرأ أيضاً

84 - Francois Henault 2018
In this paper is presented an analytical study of the azimuthal phase-mask coronagraph currently envisioned for detecting and characterizing extra-solar planets. Special emphasis is put on the physical and geometrical interpretation of the mathematic al development. Two necessary conditions are defined for achieving full extinction in the pupil plane of the coronagraph, stating that the complex amplitude generated by the phase mask should have zero average, on the one hand, and its Fourier coefficients should only be even, on the other hand. Examples of such phase functions are reviewed, including optical vortices, four-quadrant phase masks, and azimuthal cosine phase functions. Hints for building more sophisticated functions are also given. Finally, a simplified expression of light leaks due to mask imperfection is proposed
Phase apodization coronagraphs are implemented in a pupil plane to create a dark hole in the science camera focal plane. They are successfully created as Apodizing Phase Plates (APPs) using classical optical manufacturing, and as vector-APPs using li quid-crystal patterning with essentially achromatic performance. This type of coronagraph currently delivers excellent broadband contrast ($sim$10$^{-5}$) at small angular separations (few $lambda/D$) at ground-based telescopes, owing to their insensitivity to tip/tilt errors.
The design of liquid-crystal diffractive phase plate coronagraphs for ground-based and space-based high-contrast imaging systems is limited by the trade-off between spectral bandwidth and polarization leakage. We demonstrate that by combining phase p atterns with a polarization grating (PG) pattern directly followed by one or several separate PGs, we can suppress the polarization leakage terms by additional orders of magnitude by diffracting them out of the beam. textcolor{black}{Using two PGs composed of a single-layer liquid crystal structure in the lab, we demonstrate a leakage suppression of more than an order of magnitude over a bandwidth of 133 nm centered around 532 nm. At this center wavelength we measure a leakage suppression of three orders of magnitude.} Furthermore, simulations indicate that a combination of two multi-layered liquid-crystal PGs can suppress leakage to $<10^{-5}$ for 1-2.5 $mu$m and $<10^{-10}$ for 650-800 nm. We introduce multi-grating solutions with three or more gratings that can be designed to have no separation of the two circular polarization states, and offer even deeper suppression of polarization leakage. We present simulations of a triple-grating solution that has $<10^{-10}$ leakage on the first Airy ring from 450 nm to 800 nm. We apply the double-grating concept to the Vector-Vortex coronagraph of charge 4, and demonstrate in the lab that polarization leakage no longer limits the on-axis suppression for ground-based contrast levels. Lastly, we report on the successful installation and first-light results of a double-grating vector Apodizing Phase Plate pupil-plane coronagraph installed at the Large Binocular Telescope. We discuss the implications of these new coronagraph architectures for high-contrast imaging systems on the ground and in space.
High contrast imaging and spectroscopy provide unique constraints for exoplanet formation models as well as for planetary atmosphere models. But this can be challenging because of the planet-to-star small angular separation and high flux ratio. Recen tly, optimized instruments like SPHERE and GPI were installed on 8m-class telescopes. These will probe young gazeous exoplanets at large separations (~1au) but, because of uncalibrated aberrations that induce speckles in the coronagraphic images, they are not able to detect older and fainter planets. There are always aberrations that are slowly evolving in time. They create quasi-static speckles that cannot be calibrated a posteriori with sufficient accuracy. An active correction of these speckles is thus needed to reach very high contrast levels (>1e7). This requires a focal plane wavefront sensor. Our team proposed the SCC, the performance of which was demonstrated in the laboratory. As for all focal plane wavefront sensors, these are sensitive to chromatism and we propose an upgrade that mitigates the chromatism effects. First, we recall the principle of the SCC and we explain its limitations in polychromatic light. Then, we present and numerically study two upgrades to mitigate chromatism effects: the optical path difference method and the multireference self-coherent camera. Finally, we present laboratory tests of the latter solution. We demonstrate in the laboratory that the MRSCC camera can be used as a focal plane wavefront sensor in polychromatic light using an 80 nm bandwidth at 640 nm. We reach a performance that is close to the chromatic limitations of our bench: contrast of 4.5e-8 between 5 and 17 lambda/D. The performance of the MRSCC is promising for future high-contrast imaging instruments that aim to actively minimize the speckle intensity so as to detect and spectrally characterize faint old or light gaseous planets.
Exoplanet imaging and spectroscopy are now routinely achieved by dedicated instruments on large ground-based observatories (e.g. Gemini/GPI, VLT/SPHERE, or Subaru/SCExAO). In addition to extreme adaptive optics (ExAO) and post-processing methods, the se facilities make use of the most advanced coronagraphs to suppress light of an observed star and enable the observation of circumstellar environments. The Apodized Pupil Lyot Coronagraph (APLC) is one of the leading coronagraphic baseline in the current generation of instruments. This concept combines a pupil apodization, an opaque focal plane mask (FPM), and a Lyot stop. APLC can be optimized for a range of applications and designs exist for on-axis segmented aperture telescopes at $10^{10}$ contrast in broadband light. In this communication, we propose novel designs to push the limits of this concept further by modifying the nature of the FPM from its standard opaque mask to a smaller size occulting spot surrounded by circular phase shifting zones. We present the formalism of this new concept which solutions find two possible applications: 1) upgrades for the current generation of ExAO coronagraphs since these solutions remain compatible with the existing designs and will provide better inner working angle, contrast and throughput, and 2) coronagraphy at $10^{10}$ contrast for future flagship missions such as LUVOIR, with the goal to increase the throughput of the existing designs for the observation of Earth-like planets around nearby stars.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا