ترغب بنشر مسار تعليمي؟ اضغط هنا

Controlled Betatron X-Ray Radiation from Tunable Optically Injected Electrons

255   0   0.0 ( 0 )
 نشر من قبل Sebastien Corde
 تاريخ النشر 2011
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

The features of Betatron x-ray emission produced in a laser-plasma accelerator are closely linked to the properties of the relativistic electrons which are at the origin of the radiation. While in interaction regimes explored previously the source was by nature unstable, following the fluctuations of the electron beam, we demonstrate in this Letter the possibility to generate x-ray Betatron radiation with controlled and reproducible features, allowing fine studies of its properties. To do so, Betatron radiation is produced using monoenergetic electrons with tunable energies from a laser-plasma accelerator with colliding pulse injection [J. Faure et al., Nature (London) 444, 737 (2006)]. The presented study provides evidence of the correlations between electrons and x-rays, and the obtained results open significant perspectives toward the production of a stable and controlled femtosecond Betatron x-ray source in the keV range.



قيم البحث

اقرأ أيضاً

Development of x-ray phase contrast imaging applications with a laboratory scale source have been limited by the long exposure time needed to obtain one image. We demonstrate, using the Betatron x-ray radiation produced when electrons are accelerated and wiggled in the laser-wakefield cavity, that a high quality phase contrast image of a complex object (here, a bee), located in air, can be obtained with a single laser shot. The Betatron x-ray source used in this proof of principle experiment has a source diameter of 1.7 microns and produces a synchrotron spectrum with critical energy E_c=12.3 +- 2.5 keV and 10^9 photons per shot in the whole spectrum.
73 - M.S. Bloom 2017
We show that the properties of the electron beam and bright x-rays produced by a laser wakefield accelerator can be predicted if the distance over which the laser self-focuses and compresses prior to self-injection is taken into account. A model base d on oscillations of the beam inside a plasma bubble shows that performance is optimised when the plasma length is matched to the laser depletion length. With a 200~TW laser pulse this results in an x-ray beam with median photon energy of unit[20]{keV}, $> 6times 10^{8}$ photons above unit[1]{keV} per shot and a peak brightness of $unit[3 times 10^{22}]{photons~s^{-1}mrad^{-2}mm^{-2} (0.1% BW)^{-1}}$.
Direct laser acceleration (DLA) of electrons in a plasma of near critical electron density (NCD) and associated synchrotron-like radiation are discussed for moderate relativistic laser intensity (the normalized laser amplitude $a_0$ $leq$ 4.3) and ps -long pulse. This regime is typical for kJ PW-class laser facilities designed for high energy density research. Currently, in experiments at the PHELX laser it was demonstrated that interaction of 10$^{19}$ W/cm$^{2}$ sub-ps laser pulse with sub-mm long NCD plasma results in generation of high-current well-directed super-ponderomotive electrons with effective temperature that is 10$times$ higher than the ponderomotive potential [O. Rosmej et al., PPCF 62, 115024 (2020)]. Three-dimensional Particle-In-Cell simulations provided a good agreement with the measured electron energy distribution and were used in the current work to study synchrotron radiation of the DLA accelerated electrons. The resulting x-ray spectrum with a critical energy of 5 keV reveals an ultra-high photon number of 7$times$10$^{11}$ in the 1-30 keV photon energy range at the focused laser energy of 20 J. Numerical simulations of a betatron x-ray phasecontrast imaging based on the DLA process for the parameters of a PHELIX laser is presented. The results are of interest for applications in high energy density (HED) experiments, which require a picosecond x-ray pulse and a high photon flux.
130 - K. Huang , L. M. Chen , Y. F. Li 2015
A new scheme for bright hard x-ray emission from laser wakefield electron accelerator is reported, where pure nitrogen gas is adopted. Intense Betatron x-ray beams are generated from ionization injected K-shell electrons of nitrogen into the accelera ting wave bucket. The x-ray radiation shows synchrotron-like spectrum with total photon yield 8$times$10$^8$/shot and $10^8$ over 110keV. In particular, the betatron hard x-ray photon yield is 10 times higher compared to the case of helium gas under the same laser parameters. Particle-in-cell simulation suggests that the enhancement of the x-ray yield results from ionization injection, which enables the electrons to be quickly accelerated to the driving laser region for subsequent betatron resonance. Employing the present scheme,the single stage nitrogen gas target could be used to generate stable high brightness betatron hard x-ray beams.
Betatron x-ray source from laser plasma interaction combines high brightness, few femtosecond duration and broad band energy spectrum. However, despite these unique features the Betatron source has a crippling drawback preventing its use for applicat ions. Its properties significantly vary shot-to-shot and none of the developments performed so far resolved this problem. In this letter we present a simple method that allows to produce stable and bright Betatron x-ray beams. In addition, we demonstrate that this scheme provides polarized and easily tunable radiation. Experimental results show that the pointing stability is better than 10% of the beam divergence, with flux fluctuation of the order of 20% and a polarization degree reaching up to 80%
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا