ترغب بنشر مسار تعليمي؟ اضغط هنا

An optical device for ultra-cold neutrons - Investigation of systematic effects and applications

161   0   0.0 ( 0 )
 نشر من قبل Christian Plonka
 تاريخ النشر 2009
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

We developed an optical device for ultra-cold neutrons and investigated the influence of a tilt of its guiding components. A measurement of the time-of-flight of the neutrons through the device by means of a dedicated chopper system was performed and a light-optical method for the alignment of the guiding components is demonstrated. A comparative analysis of former experiments with our results shows the potential of such a device to test the electrical neutrality of the free neutron on the $10^{-22} q_{rm e}$ level and to investigate the interaction of neutrons with gravity.



قيم البحث

اقرأ أيضاً

This work presents selected results from the first round of the DFG Priority Programme SPP 1491 precision experiments in particle and astroparticle physics with cold and ultra-cold neutrons.
A pixel detector with high spatial resolution and temporal information for ultra-cold neutrons is developed based on a commercial CCD on which a neutron converter is attached. 10B and 6Li are tested for the neutron converter and 10B is found to be mo re suitable based on efficiency and spatial resolution. The pixel detector has an efficiency of 44.1 +- 1.1% and a spatial resolution of 2.9 +- 0.1 um (1 sigma).
We report on the fabrication and use of deuterated polyethylene (dPE) as a coating material for ultra-cold neutron (UCN) storage and transport. The Fermi potential has been determined to be 214~neV and the wall loss coefficient $eta$ is 1.3$cdot$10$^ 4$ per wall collision. The coating technique allows for a wide range of applications and new possibilities in this field of physics. In particular, flexible and quasi-massless UCN guides with slit-less shutters and slit-less UCN storage volumes become possible. These properties enable the use in next-generation measurements of the electric dipole moment of the neutron.
224 - S. Afach , G. Ban , G. Bison 2015
We report on the design and first tests of a device allowing for measurement of ultracold neutrons polarisation by means of the simultaneous analysis of the two spin components. The device was developed in the framework of the neutron electric dipole moment experiment at the Paul Scherrer Institute. Individual parts and the entire newly built system have been characterised with ultracold neutrons. The gain in statistical sensitivity obtained with the simultaneous spin analyser is $(18.2pm6.1)%$ relative to the former sequential analyser under nominal running conditions.
We present two new types of spectroscopy methods for cold and ultra-cold neutrons. The first method, which uses the RB drift effect to disperse charged particles in a uniformly curved magnetic field, allows to study neutron $beta$-decay. We aim for a precision on the 10$^{-4}$ level. The second method that we refer to as gravity resonance spectroscopy (GRS) allows to test Newtons gravity law at short distances. At the level of precision we are able to provide constraints on any possible gravity-like interaction. In particular, limits on dark energy chameleon fields are improved by several orders of magnitude.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا