ﻻ يوجد ملخص باللغة العربية
In this paper we describe the photometric calibration of data taken with the near-infrared Wide Field Camera (WFCAM) on the United Kingdom Infrared Telescope (UKIRT). The broadband ZYJHK data are directly calibrated from 2MASS point sources which are abundant in every WFCAM pointing. We perform an analysis of spatial systematics in the photometric calibration, both inter- and intra-detector and show that these are present at up to the 5 per cent level in WFCAM. Although the causes of these systematics are not yet fully understood, a method for their removal is developed and tested. Following application of the correction procedure the photometric calibration of WFCAM is found to be accurate to approximately 1.5 per cent for the JHK bands and 2 per cent for the ZY bands, meeting the survey requirements. We investigate the transformations between the 2MASS and WFCAM systems and find that the Z and Y calibration is sensitive to the effects of interstellar reddening for large values of E(B-V), but that the JHK filters remain largely unaffected. We measure a small correction to the WFCAM Y-band photometry required to place WFCAM on a Vega system, and investigate WFCAM measurements of published standard stars from the list of UKIRT faint standards. Finally we present empirically determined throughput measurements for WFCAM.
The UKIRT Infrared Deep Sky Survey is a set of five surveys of complementary combinations of area, depth, and Galactic latitude, which began in 2005 May. The surveys use the UKIRT Wide Field Camera (WFCAM), which has a solid angle of 0.21deg^2. Here
We present results from the application of a global photometric calibration (GPC) procedure to calibration data from the first 2 years of The Two Micron All Sky Survey (2MASS). The GPC algorithm uses photometry of both primary standards and moderatel
The Nanshan One-meter Wide-field Telescope (NOWT) is a prime focus system located at Nanshan Station of Xinjiang Astronomical Observatories (XAO). The field of view(FOV) was designed to 1.5 degree *1.5 degree, and Johnson-Cousins UBVRI system was cho
We address the problem of estimating the 3D pose of a network of cameras for large-environment wide-baseline scenarios, e.g., cameras for construction sites, sports stadiums, and public spaces. This task is challenging since detecting and matching th
We present the photometric calibration of the HST Advanced Camera for Surveys (ACS). We give here an overview of the performance and calibration of the 2 CCD cameras, the Wide Field Channel (WFC) and the High Resolution Channel (HRC), and a descripti