The AMANDE facility at IRSN-Cadarache produces mono-energetic neutron fields from 2 keV to 20 MeV with metrological quality. To be considered as a standard facility, characteristics of neutron field i.e fluence distribution must be well known by a device using absolute measurements. The development of new detector systems allowing a direct measurement of neutron energy and fluence has started in 2006. Using the proton recoil telescope principle with the goal of increase the efficiency, two systems with full localization are studied. A proton recoil telescope using CMOS sensor (CMOS-RPT) is studied for measurements at high energies and the helium 4 gaseous micro-time projection chamber (microTPC He4) will be dedicated to the lowest energies. Simulations of the two systems were performed with the transport Monte Carlo code MCNPX, to choose the components and the geometry, to optimize the efficiency and detection limits of both devices or to estimate performances expected. First preliminary measurements realised in 2008 demonstrated the proof of principle of these novel detectors for neutron metrology.



قيم البحث

اقرأ أيضاً

The e_LiBANS project aims at creating accelerator based compact neutron facilities for diverse interdisciplinary applications. After the successful setting up and characterization of a thermal neutron source based on a medical electron LINAC, a simil ar assembly for epithermal neutrons has been developed. The project is based on an Elekta 18 MV LINAC coupled with a photoconverter-moderator system which deploys the ({gamma},n) photonuclear reaction to convert a bremsstrahlung photon beam into a neutron field. This communication describes the development of novel diagnostics to qualify the thermal and epithermal neutron fields that have been produced. In particular, a proof of concept for the use of silicon carbide photodiodes as a thermal neutron rate detector is presented.
Recently, the facilities of radioactive ion beam (RIB) combined with advanced detector systems provide us unique opportunity to probe the exotic properties of the nuclei with unusual neutron-to-proton ratio. In this article, a study of characterizati on of different types of ultra-fast timing detectors: a special type of gas detector (multi-strip multi-gap resistive plate chamber, MMRPC) ($sigma$ $<$100 ps), scintillators array ( viz., $LaBr_3:Ce$) (timing resolution ($sigma<$250 ps) are being presented. A brief discussion on usage of these different types of ultra-fast timing detector systems at radioactive ion beam facilities is also included.
We report on the design, production, and performance of compact 40-cm$^3$ Time Projection Chambers (TPCs) that detect fast neutrons by measuring the three-dimensional (3D) ionization distribution of nuclear recoils in $^4$He:CO$_2$ gas at atmospheric pressure. We use these detectors to characterize the fast-neutron flux inside the Belle II detector at the SuperKEKB electron-positron collider in Tsukuba, Japan, where the primary design constraint is a small form factor. We find that the TPCs meet or exceed all design specifications, and are capable of measuring the 3D surface shape and charge density profile of ionization clouds from nuclear recoils and charged tracks in exquisite detail. Scaled-up detectors based on the detection principle demonstrated here may be suitable for directional dark matter searches, measurements of coherent neutrino-nucleus scattering, and other experiments requiring precise detection of neutrons or nuclear recoils.
The ambitious instrument suite for the future European Spallation Source whose civil construction started recently in Lund, Sweden, demands a set of diverse and challenging requirements for the neutron detectors. For instance, the unprecedented high flux expected on the samples to be investigated in neutron diffraction or reflectometry experiments requires detectors that can handle high counting rates, while the investigation of sub-millimeter protein crystals will only be possible with large-area detectors that can achieve a position resolution as low as 200 {mu}m. This has motivated an extensive research and development campaign to advance the state-of-the-art detector and to find new technologies that can reach maturity by the time the ESS will operate at full potential. This paper presents the key detector requirements for three of the Time-of-Flight diffraction instrument concepts selected by the Scientific Advisory Committee to advance into the phase of preliminary engineering design. We discuss the available detector technologies suitable for this particular instrument class and their major challenges. The detector technologies selected by the instrument teams to collect the diffraction patterns are briefly discussed. Analytical calculations, Monte-Carlo simulations, and real experimental data are used to develop a generic method to esti- mate the event rate in the diffraction detectors. The proposed approach is based upon conservative assumptions that use information and input parameters that reflect our current level of knowledge and understanding of the ESS project. We apply this method to make predictions for the future diffraction instruments, and thus provide additional information that can help the instrument teams with the optimisation of the detector designs.
The KATRIN experiment aims to determine the neutrino mass scale with a sensitivity of 200 meV/c^2 (90% C.L.) by a precision measurement of the shape of the tritium $beta$-spectrum in the endpoint region. The energy analysis of the decay electrons is achieved by a MAC-E filter spectrometer. To determine the transmission properties of the KATRIN main spectrometer, a mono-energetic and angular-selective electron source has been developed. In preparation for the second commissioning phase of the main spectrometer, a measurement phase was carried out at the KATRIN monitor spectrometer where the device was operated in a MAC-E filter setup for testing. The results of these measurements are compared with simulations using the particle-tracking software Kassiopeia, which was developed in the KATRIN collaboration over recent years.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا