Acceptance and resolution simulation studies for the dielectron spectrometer HADES at GSI


الملخص بالإنكليزية

Design studies for a second generation Dilepton Spectrometer to be built at the SIS accelerator of GSI are presented. The basic design parameters of this system are specified and the different detector components for charged particle tracking and for lepton identification are described. The geometrical acceptance for lepton pairs is given. Results on single track momentum resolution and on lepton pair mass resolution are reported.