ترغب بنشر مسار تعليمي؟ اضغط هنا

Multi-speckle diffusing wave spectroscopy with a single mode detection scheme

122   0   0.0 ( 0 )
 نشر من قبل Pavel Zakharov
 تاريخ النشر 2005
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

We present a detection scheme for diffusing wave spectroscopy (DWS) based on a two cell geometry that allows efficient ensemble averaging. This is achieved by putting a fast rotating diffuser in the optical path between laser and sample. We show that the recorded (multi-speckle) correlation echoes provide an ensemble averaged signal that does not require additional time averaging. We find the performance of our experimental scheme comparable or even superior to camera based multi-speckle techniques that rely on direct spatial averaging. Furthermore, combined with traditional two-cell DWS, the full intensity autocorrelation function can be measured with a single experimental setup covering more than 10 decades in correlation time.



قيم البحث

اقرأ أيضاً

We introduce an elegant method which allows the application of diffusing-wave spectroscopy (DWS) to nonergodic, solid-like samples. The method is based on the idea that light transmitted through a sandwich of two turbid cells can be considered ergodi c even though only the second cell is ergodic. If absorption and/or leakage of light take place at the interface between the cells, we establish a so-called multiplication rule, which relates the intensity autocorrelation function of light transmitted through the double-cell sandwich to the autocorrelation functions of individual cells by a simple multiplication. To test the proposed method, we perform a series of DWS experiments using colloidal gels as model nonergodic media. Our experimental data are consistent with the theoretical predictions, allowing quantitative characterization of nonergodic media and demonstrating the validity of the proposed technique.
Diffusing wave spectroscopy (DWS) is a well-known set of methods to measure the temporal dynamics of dynamic samples. In DWS, dynamic samples scatter the incident coherent light, and the information of the temporal dynamics is encoded in the scattere d light. To record and analyze the light signal, there exist two types of methods - temporal sampling methods and speckle ensemble methods. Temporal sampling methods, including diffuse correlation spectroscopy (DCS), use one or multiple large bandwidth detectors to well sample and analyze the temporal light signal to infer the sample temporal dynamics. Speckle ensemble methods, including speckle visibility spectroscopy (SVS), use a high-pixel-count camera sensor to capture a speckle pattern and use the speckle contrast to infer sample temporal dynamics. In this paper, we theoretically and experimentally demonstrate that the decorrelation time ({tau}) measurement accuracy or SNR of the two types of methods has a unified and similar fundamental expression based on the number of independent observables (NIO) and the photon flux. Given a time measurement duration, NIO in temporal sampling methods is constrained by the measurement duration, while speckle ensemble methods can outperform by using simultaneous sampling channels to scale up NIO significantly. In the case of optical brain monitoring, the interplay of these factors favors speckle ensemble methods. We illustrate that this important engineering consideration is consistent with the previous research on blood pulsatile flow measurements, where a speckle ensemble method operating at 100-fold lower photon flux than a conventional temporal sampling system can achieve a comparable SNR.
Diffusing wave spectroscopy (DWS) can be employed as an optical rheology tool with numerous applications for studying the structure, dynamics and linear viscoelastic properties of complex fluids, foams, glasses and gels. To carry out DWS measurements , one first needs to quantify the static optical properties of the sample under investigation, i.e. the transport mean free path $l^ast$ and the absorption length $l_a$. In the absence of absorption this can be done by comparing the diffuse optical transmission to a calibration sample whose $l^ast$ is known. Performing this comparison however is cumbersome, time consuming and prone to mistakes by the operator. Moreover, already weak absorption can lead to significant errors. In this paper, we demonstrate the implementation of an automatized approach, based on which the DWS measurement procedure can be simplified significantly. By comparison with a comprehensive set of calibration measurements we cover the entire parameter space relating measured count rates (CR$_t$, CR$_b$) to ($l^ast$, $l_a$). Based on this approach we can determine $l^ast$ and $l_a$ of an unknown sample accurately thus making the additional measurement of a calibration sample obsolete. We illustrate the use of this approach by monitoring the coarsening of a commercially available shaving foam with DWS.
We consider the hydrodynamics of lipid bilayers containing transmembrane proteins of arbitrary shape. This biologically-motivated problem is relevant to the cell membrane, whose fluctuating dynamics play a key role in phenomena ranging from cell migr ation, intercellular transport, and cell communication. Using Onsagers variational principle, we derive the equations that govern the relaxation dynamics of the membrane shape, of the mass densities of the bilayer leaflets, and of the diffusing proteins concentration. With our generic formalism, we obtain several results on membrane dynamics. We find that proteins that span the bilayer increase the intermonolayer friction coefficient. The renormalization, which can be significant, is in inverse proportion to the proteins mobility. Second, we find that asymmetric proteins couple to the membrane curvature and to the difference in monolayer densities. For practically all accessible membrane tensions ($sigma> 10^{-8}$ N/m) we show that the protein density is the slowest relaxing variable. Furthermore, its relaxation rate decreases at small wavelengths due to the coupling to curvature. We apply our formalism to the large-scale diffusion of a concentrated protein patch. We find that the diffusion profile is not self-similar, owing to the wavevector dependence of the effective diffusion coefficient.
We report observations of nanosecond nanometer scale heterogeneous dynamics in a free flowing colloidal jet revealed by ultrafast x-ray speckle visibility spectroscopy. The nanosecond double-bunch mode of the Linac Coherent Light Source free electron laser enabled the production of pairs of femtosecond coherent hard x-ray pulses. By exploring the anisotropic summed speckle visibility which relates to the correlation functions, we are able to evaluate not only the average particle flow rate in a colloidal nanoparticle jet, but also the heterogeneous flow field within. The reported methodology presented here establishes the foundation for the study of nano- and atomic-scale heterogeneous fluctuations in complex matter using x-ray free electron laser sources.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا