ترغب بنشر مسار تعليمي؟ اضغط هنا

A Compact X-ray Source and Possible X-ray Jets within the Planetary Nebula Menzel 3

117   0   0.0 ( 0 )
 نشر من قبل Joel Kastner
 تاريخ النشر 2003
  مجال البحث فيزياء
والبحث باللغة English
 تأليف Joel H. Kastner




اسأل ChatGPT حول البحث

We report the discovery, by the Chandra X-ray Observatory, of X-ray emission from the bipolar planetary nebula Menzel 3. In Chandra CCD imaging, Mz 3 displays hot (3-6x10^6 K) gas within its twin, coaxial bubbles of optical nebulosity, as well as a compact X-ray source at the position of its central star(s). The brightest diffuse X-ray emission lies along the polar axis of the optical nebula, suggesting a jet-like configuration. The observed combination of an X-ray-emitting point source and possible X-ray jet(s) is consistent with models in which accretion disks and, potentially, magnetic fields shape bipolar planetary nebulae via the generation of fast, collimated outflows.



قيم البحث

اقرأ أيضاً

104 - Raghvendra Sahai 2003
We report the first detection of X-ray emission in a pre-planetary nebula, Hen 3-1475. Pre-planetary nebulae are rare objects in the short transition stage between the Asymptotic Giant Branch and planetary nebula evolutionary phases, and Hen 3-1475, characterised by a remarkable S-shaped chain of optical knots, is one of the most noteworthy members of this class. Observations with the Advanced CCD Imaging Spectrometer (ACIS) onboard the Chandra X-Ray observatory show the presence of compact emission coincident with the brightest optical knot in this bipolar object, which is displaced from the central star by 2.7 arcsec along the polar axis. Model fits to the X-ray spectrum indicate an X-ray temperature and luminosity, respectively, of (4.3-5.7) 10^6 K and (4+/-1.4) 10^{31} (D/5 kpc)^2 erg s^{-1}, respectively. Our 3-sigma upper limit on the luminosity of compact X-ray emission from the central star in Hen 3-1475 is ~5 10^{31} (D/5 kpc)^2 erg s^{-1}. The detection of X-rays in Hen 3-1475 is consistent with models in which fast collimated post-AGB outflows are crucial to the shaping of planetary nebulae; we discuss such models in the context of our observations.
114 - M. Freeman 2014
We present results from the most recent set of observations obtained as part of the Chandra X-ray observatory Planetary Nebula Survey (ChanPlaNS), the first comprehensive X-ray survey of planetary nebulae (PNe) in the solar neighborhood (i.e., within ~1.5 kpc of the Sun). The survey is designed to place constraints on the frequency of appearance and range of X-ray spectral characteristics of X-ray-emitting PN central stars and the evolutionary timescales of wind-shock-heated bubbles within PNe. ChanPlaNS began with a combined Cycle 12 and archive Chandra survey of 35 PNe. ChanPlaNS continued via a Chandra Cycle 14 Large Program which targeted all (24) remaining known compact (R_neb <~ 0.4 pc), young PNe that lie within ~1.5 kpc. Results from these Cycle 14 observations include first-time X-ray detections of hot bubbles within NGC 1501, 3918, 6153, and 6369, and point sources in HbDs 1, NGC 6337, and Sp 1. The addition of the Cycle 14 results brings the overall ChanPlaNS diffuse X-ray detection rate to ~27% and the point source detection rate to ~36%. It has become clearer that diffuse X-ray emission is associated with young (<~5x10^3 yr), and likewise compact (R_neb<~0.15 pc), PNe with closed structures and high central electron densities (n_e>~1000 cm^-3), and rarely associated with PNe that show H_2 emission and/or pronounced butterfly structures. Hb 5 is one such exception of a PN with a butterfly structure that hosts diffuse X-ray emission. Additionally, of the five new diffuse X-ray detections, two host [WR]-type CSPNe, NGC 1501 and NGC 6369, supporting the hypothesis that PNe with central stars of [WR]-type are likely to display diffuse X-ray emission.
113 - S. Markoff 2003
Astrophysical jets exist in both XRBs and AGN, and seem to share common features, particularly in the radio. While AGN jets are known to emit X-rays, the situation for XRB jets is not so clear. Radio jets have been resolved in several XRBs in the low /hard state, establishing that some form of outflow is routinely present in this state. Interestingly, the flat-to-inverted radio synchrotron emission associated with these outflows strongly correlates with the X-ray emission in several sources, suggesting that the jet plasma plays a role at higher frequencies. In this same state, there is increasing evidence for a turnover in the IR/optical where the flat-to-inverted spectrum seems to connect to an optically thin component extending into the X-rays. We discuss how jet synchrotron emission is likely to contribute to the X-rays, in addition to inverse Compton up-scattering, providing a natural explanation for these correlations and the turnover in the IR/optical band. We present model parameters for fits to several sources, and address some common misconceptions about the jet model.
X-ray calorimeters routinely achieve very high spectral resolution, typically a few eV full width at half maximum (FWHM). Measurements of calorimeter line shapes are usually dominated by the natural linewidth of most laboratory calibration sources. T his compounds the data acquisition time necessary to statistically sample the instrumental line broadening, and can add systematic uncertainty if the intrinsic line shape of the source is not well known. To address these issues, we have built a simple, compact monochromatic x-ray source using channel cut crystals. A commercial x-ray tube illuminates a pair of channel cut crystals which are aligned in a dispersive configuration to select the kaone line of the x-ray tube anode material. The entire device, including x-ray tube, can be easily hand carried by one person and may be positioned manually or using a mechanical translation stage. The output monochromatic beam provides a collimated image of the anode spot with magnification of unity in the dispersion direction (typically 100-200 $mu$m for the x-ray tubes used here), and is unfocused in the cross-dispersion direction, so that the source image in the detector plane appears as a line. We measured output count rates as high as 10 count/s/pixel for the Hitomi Soft X-ray Spectrometer, which had 819 $mu$m square pixels. We implemented different monochromator designs for energies of 5.4 keV (one design) and 8.0 keV (two designs) which have effective theoretical FWHM energy resolution of 0.125, 0.197, and 0.086 eV, respectively; these are well-suited for optimal calibration measurements of state-of-the art x-ray calorimeters. We measured an upper limit for the energy resolution of our crkaone monochromator of 0.7 eV FWHM at 5.4 keV, consistent with the theoretical prediction of 0.125 eV.
415 - E. Ripamonti 2010
Recent models of the formation of ultra-luminous X-ray sources (ULXs) predict that they preferentially form in low-metallicity environments. We look at the metallicity of the nebula surrounding NGC 1313 X-2, one of the best-studied ULXs. Simple estim ates, based on the extrapolation of the metallicity gradient within NGC 1313, or on empirical calibrations (relating metallicity to strong oxygen lines) suggest a quite low metal content (Z ~ 0.1 Zsun). But such estimates do not account for the remarkably strong X-ray flux irradiating the nebula. Then, we build photoionization models of the nebula using CLOUDY; using such models, the constraints on the metallicity weaken substantially, as we find 0.15 Zsun <= Z <= 0.5 Zsun.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا