ترغب بنشر مسار تعليمي؟ اضغط هنا

Resilience to Denial-of-Service and Integrity Attacks: A Structured Systems Approach

88   0   0.0 ( 0 )
 نشر من قبل Bhaskar Ramasubramanian
 تاريخ النشر 2021
والبحث باللغة English




اسأل ChatGPT حول البحث

The resilience of cyberphysical systems to denial-of-service (DoS) and integrity attacks is studied in this paper. The cyberphysical system is modeled as a linear structured system, and its resilience to an attack is interpreted in a graph theoretical framework. The structural resilience of the system is characterized in terms of unmatched vertices in maximum matchings of the bipartite graph and connected components of directed graph representations of the system under attack. We first present conditions for the system to be resilient to DoS attacks when an adversary may block access or turn off certain inputs to the system. We extend this analysis to characterize resilience of the system when an adversary might additionally have the ability to affect the implementation of state-feedback control strategies. This is termed an integrity attack. We establish conditions under which a system that is structurally resilient to a DoS attack will also be resilient to a certain class of integrity attacks. Finally, we formulate an extension to the case of switched linear systems, and derive conditions for such systems to be structurally resilient to a DoS attack.



قيم البحث

اقرأ أيضاً

In this paper, we study the problem of localizing the sensors positions in presence of denial-of-service (DoS) attacks. We consider a general attack model, in which the attacker action is only constrained through the frequency and duration of DoS att acks. We propose a distributed iterative localization algorithm with an abandonment strategy based on the barycentric coordinate of a sensor with respect to its neighbors, which is computed through relative distance measurements. In particular, if a sensors communication links for receiving its neighbors information lose packets due to DoS attacks, then the sensor abandons the location estimation. When the attacker launches DoS attacks, the AS-DILOC algorithm is proved theoretically to be able to accurately locate the sensors regardless of the attack strategy at each time. The effectiveness of the proposed algorithm is demonstrated through simulation examples.
State estimation is of considerable significance for the power system operation and control. However, well-designed false data injection attacks can utilize blind spots in conventional residual-based bad data detection methods to manipulate measureme nts in a coordinated manner and thus affect the secure operation and economic dispatch of grids. In this paper, we propose a detection approach based on an autoencoder neural network. By training the network on the dependencies intrinsic in normal operation data, it effectively overcomes the challenge of unbalanced training data that is inherent in power system attack detection. To evaluate the detection performance of the proposed mechanism, we conduct a series of experiments on the IEEE 118-bus power system. The experiments demonstrate that the proposed autoencoder detector displays robust detection performance under a variety of attack scenarios.
Cyber-Physical Systems (CPS) are present in many settings addressing a myriad of purposes. Examples are Internet-of-Things (IoT) or sensing software embedded in appliances or even specialised meters that measure and respond to electricity demands in smart grids. Due to their pervasive nature, they are usually chosen as recipients for larger scope cyber-security attacks. Those promote system-wide disruptions and are directed towards one key aspect such as confidentiality, integrity, availability or a combination of those characteristics. Our paper focuses on a particular and distressing attack where coordinated malware infected IoT units are maliciously employed to synchronously turn on or off high-wattage appliances, affecting the grids primary control management. Our model could be extended to larger (smart) grids, Active Buildings as well as similar infrastructures. Our approach models Coordinated Load-Changing Attacks (CLCA) also referred as GridLock or BlackIoT, against a theoretical power grid, containing various types of power plants. It employs Continuous-Time Markov Chains where elements such as Power Plants and Botnets are modelled under normal or attack situations to evaluate the effect of CLCA in power reliant infrastructures. We showcase our modelling approach in the scenario of a power supplier (e.g. power plant) being targeted by a botnet. We demonstrate how our modelling approach can quantify the impact of a botnet attack and be abstracted for any CPS system involving power load management in a smart grid. Our results show that by prioritising the type of power-plants, the impact of the attack may change: in particular, we find the most impacting attack times and show how different strategies impact their success. We also find the best power generator to use depending on the current demand and strength of attack.
Finite-time stability of networked control systems under Denial of Service (DoS) attacks are investigated in this paper, where the communication between the plant and the controller is compromised at some time intervals. Toward this goal, first an ev ent-triggered mechanism based on the variation rate of the Lyapunov function is proposed such that the closed-loop system remains finite-time stable (FTS) and at the same time, the amount data exchange in the network is reduced. Next, the vulnerability of the proposed event-triggered finite-time controller in the presence of DoS attacks are evaluated and sufficient conditions on the DoS duration and frequency are obtained to assure the finite-time stability of the closed-loop system in the presence of DoS attack where no assumption on the DoS attack in terms of following a certain probabilistic or a well-structured periodic model is considered. Finally, the efficiency of the proposed approach is demonstrated through a simulation study.
The electric power grid is a complex cyberphysical energy system (CPES) in which information and communication technologies (ICT) are integrated into the operations and services of the power grid infrastructure. The growing number of Internet-of-thin gs (IoT) high-wattage appliances, such as air conditioners and electric vehicles, being connected to the power grid, together with the high dependence of ICT and control interfaces, make CPES vulnerable to high-impact, low-probability load-changing cyberattacks. Moreover, the side-effects of the COVID-19 pandemic demonstrate a modification of electricity consumption patterns with utilities experiencing significant net-load and peak reductions. These unusual sustained low load demand conditions could be leveraged by adversaries to cause frequency instabilities in CPES by compromising hundreds of thousands of IoT-connected high-wattage loads. This paper presents a feasibility study of the impacts of load-changing attacks on CPES during the low loading conditions caused by the lockdown measures implemented during the COVID-19 pandemic. The load demand reductions caused by the lockdown measures are analyzed using dynamic mode decomposition (DMD), focusing on the March-to-July 2020 period and the New York region as the most impacted time period and location in terms of load reduction due to the lockdowns being in full execution. Our feasibility study evaluates load-changing attack scenarios using real load consumption data from the New York Independent System Operator (NYISO) and shows that an attacker with sufficient knowledge and resources could be capable of producing frequency stability problems, with frequency excursions going up to 60.5 Hz and 63.4 Hz, when no mitigation measures are taken.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا