ﻻ يوجد ملخص باللغة العربية
Respiration causes time-varying frequency offsets that can result in ghosting artifacts. We propose a solution, which we term dynamic realtime z-shimming, wherein linear gradients are adjusted dynamically (slice-wise) and in real-time, to reflect magnetic field inhomogeneities that arise during image acquisition. In dynamic z-shimming, a method that is commonly used to reduce static frequency offsets in MR images of the spinal cord and brain, in-plane (static) frequency offsets are assumed to be homogeneous. Here we investigate whether or not that same assumption can be made for time-varying frequency offsets in the cervical spinal cord region. In order to explore the feasibility of dynamic realtime z-shimming, we acquired images using a pneumatic phantom setup, as well as in-vivo. We then simulated the effects of time-varying frequency offsets on MR images acquired with and without dynamic realtime z-shimming in different scenarios. We found that dynamic realtime z-shimming can reduce ghosting if the time-varying frequency offsets have an in-plane variability (standard deviation) of approximately less than 1 Hz. This scenario was achieved in our phantom setup, where we observed a 50.2% reduction in ghosting within multi-echo gradient echo images acquired with dynamic realtime z-shimming, compared to without. On the other hand, we observed that the in-plane variability of the time-varying frequency offsets is too high within the cervical spinal cord region for dynamic realtime z-shimming to be successful. These results can serve as a guideline and starting point for future dynamic realtime z-shimming experiments in which the in-plane variability of frequency offsets are minimized.
Oscillating Steady-State Imaging (OSSI) is a recent fMRI acquisition method that exploits a large and oscillating signal, and can provide high SNR fMRI. However, the oscillatory nature of the signal leads to an increased number of acquisitions. To im
A to-date unsolved and highly limiting safety concern for Ultra High-Field (UHF) magnetic resonance imaging (MRI) is the deposition of radiofrequency (RF) power in the body, quantified by the specific absorption rate (SAR), leading to dangerous tissu
When no arterial input function is available, quantification of dynamic PET images requires a previous step devoted to the extraction of a reference time-activity curve (TAC). Factor analysis is often applied for this purpose. This paper introduces a
Direct reconstruction methods have been developed to estimate parametric images directly from the measured PET sinograms by combining the PET imaging model and tracer kinetics in an integrated framework. Due to limited counts received, signal-to-nois
Recurrent neural networks (RNNs) have been widely adopted in temporal sequence analysis, where realtime performance is often in demand. However, RNNs suffer from heavy computational workload as the model often comes with large weight matrices. Prunin