ﻻ يوجد ملخص باللغة العربية
We present the probability distribution of the systematic errors in the most accurate, high-latency version of the reconstructed dimensionless strain $h$, at the Hanford and Livingston LIGO detectors, used for gravitational-wave astrophysical analysis, including parameter estimation, in the last five months of the third observing run (O3B). This work extends the results presented in Sun et. al (2020) [1] for the first six months of the third observing run (O3A). The complex-valued, frequency-dependent, and slowly time-varying systematic error (excursion from unity magnitude and zero phase) in O3B generally remains at a consistent level as in O3A, yet changes of detector configurations in O3B have introduced a non-negligible change in the frequency dependence of the error, leading to larger excursions from unity at some frequencies and/or during some observational periods; in some other periods the excursions are smaller than those in O3A. For O3B, the upper limit on the systematic error and associated uncertainty is 11.29% in magnitude and 9.18 deg in phase (68% confidence interval) in the most sensitive frequency band 20-2000 Hz. The systematic error alone is estimated at levels of < 2% in magnitude and $lesssim 4$ deg in phase. These errors and uncertainties are dominated by the imperfect modeling of the frequency dependence of the detector response functions rather than the uncertainty in the absolute reference, the photon calibrators.
The raw outputs of the detectors within the Advanced Laser Interferometer Gravitational-Wave Observatory need to be calibrated in order to produce the estimate of the dimensionless strain used for astrophysical analyses. The two detectors have been u
The characterization of the Advanced LIGO detectors in the second and third observing runs has increased the sensitivity of the instruments, allowing for a higher number of detectable gravitational-wave signals, and provided confirmation of all obser
Advanced LIGOs raw detector output needs to be calibrated to compute dimensionless strain h(t). Calibrated strain data is produced in the time domain using both a low-latency, online procedure and a high-latency, offline procedure. The low-latency h(
This paper presents an adaptable, parallelizable method for subtracting linearly coupled noise from Advanced LIGO data. We explain the features developed to ensure that the process is robust enough to handle the variability present in Advanced LIGO d
Hardware injections are simulated gravitational-wave signals added to the Laser Interferometer Gravitational-wave Observatory (LIGO). The detectors test masses are physically displaced by an actuator in order to simulate the effects of a gravitationa