ترغب بنشر مسار تعليمي؟ اضغط هنا

Holographic Calibration of Phased Array Telescopes

60   0   0.0 ( 0 )
 نشر من قبل Randall Wayth
 تاريخ النشر 2021
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

In radio astronomy, holography is a commonly used technique to create an image of the electric field distribution in the aperture of a dish antenna. The image is used to detect imperfections in the reflector surface. Similarly, holography can be applied to phased array telescopes, in order to measure the complex gains of the receive paths of individual antennas. In this paper, a holographic technique is suggested to calibrate the digital beamformer of a phased array telescope. The effectiveness of the technique was demonstrated by applying it on data from the Engineering Development Array 2, one of the prototype stations of the low frequency component of the Square Kilometre Array. The calibration method is very quick and requires few resources. In contrast to holography for dish antennas, it works without a reference antenna. We demonstrate the utility of this technique for initial station commissioning and verification as well as for routine station calibration.



قيم البحث

اقرأ أيضاً

The results of four recently introduced beamforming schemes for phased array systems are discussed, each of which is capable to provide high sensitivity and accurate polarimetric performance of array-based radio telescopes. Ideally, a radio polarimet er should recover the actual polarization state of the celestial source, and thus compensate for unwanted polarization degradation effects which are intrinsic to the instrument. In this paper, we compare the proposed beamforming schemes through an example of a practical phased array system (APERTIF prototype) and demonstrate that the optimal beamformer, the max-SLNR beamformer, the eigenvector beamformer, and the bi-scalar beamformer are sensitivity equivalent but lead to different polarization state solutions, some of which are sub-optimal.
We present a detailed description of the special procedures for calibration and quality assurance of Atacama Large Millimeter/submillimeter Array (ALMA) observations in Very Long Baseline Interferometry (VLBI) mode. These procedures are required to t urn the phased ALMA array into a fully calibrated VLBI station. As an illustration of these methodologies, we present full-polarization observations carried out with ALMA as a phased array at 3mm (Band 3) and 1.3mm (Band 6) as part of Cycle-4. These are the first VLBI science observations conducted with ALMA and were obtained during a 2017 VLBI campaign in concert with other telescopes worldwide as part of the Global mm-VLBI Array (GMVA, April 1-3) and the Event Horizon Telescope (EHT, April 5-11) in ALMA Bands 3 and 6, respectively.
In this report we present a model for phased array feed (PAF) and compare the model predictions with measurements. A theory for loss-less PAF is presented first. To develop the theory we ask the question -- what is the best $T_{sys}/eta_{ap}$ that ca n be achieved when a PAF is used on a telescope to observe a source at an angle $theta_s, phi_s$ from the boresight direction ? We show that a characteristic matrix for the {em system} (i.e. PAF+telescope+receiver) can be constructed starting from the signal-to-noise ratio of the observations and the best $T_{sys}/eta_{ap}$ can be obtained from the maximum eigenvalue of the characteristic matrix. For constructing the characteristic matrix, we derive the open-circuit voltage at the output of the antenna elements in the PAF due to (a) radiation from source, (b) radiation from ground (spillover), (c) radiation from sky background and (d) noise due to the receiver. The characteristic matrix is then obtained from the correlation matrices of these voltages. We then describe a modeling program developed to implement the theory presented here. Finally the model predictions are compared with results from test observations made toward Virgo A with a prototype PAF (Kite array) on the GBT (Roshi et al. 2015).
The GCT is a dual-mirror Small-Sized-Telescope prototype proposed for the Cherenkov Telescope Array. Calibration of the GCTs camera is primarily achieved with LED-based flasher units capable of producing $sim4$ ns FWHM pulses of 400 nm light across a large dynamic range, from 0.1 up to 1000 photoelectrons. The flasher units are housed in the four corners of the cameras focal plane and illuminate it via reflection from the secondary mirror. These flasher units are adaptable to allow several calibration scenarios to be accomplished: camera flat-fielding, linearity measurements (up to and past saturation), and gain estimates from both single pe measurements and from the photon statistics at various high illumination levels. In these proceedings, the performance of the GCT flashers is described, together with ongoing simulation work to quantify the efficiency of using muon rings as an end-to-end calibration for the optical throughput of the GCT.
We have measured the aperture-array noise temperature of the first Mk. II phased array feed that CSIRO has built for the Australian Square Kilometre Array Pathfinder telescope. As an aperture array, the Mk. II phased array feed achieves a beam equiva lent noise temperature less than 40 K from 0.78 GHz to 1.7 GHz and less than 50 K from 0.7 GHz to 1.8 GHz for a boresight beam directed at the zenith. We believe these are the lowest reported noise temperatures over these frequency ranges for ambient-temperature phased arrays. The measured noise temperature includes receiver electronics noise, ohmic losses in the array, and stray radiation from sidelobes illuminating the sky and ground away from the desired field of view. This phased array feed was designed for the Australian Square Kilometre Array Pathfinder to demonstrate fast astronomical surveys with a wide field of view for the Square Kilometre Array.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا