ترغب بنشر مسار تعليمي؟ اضغط هنا

Performance of the UVIT Level-2 Pipeline

75   0   0.0 ( 0 )
 نشر من قبل Swarna Kanti Ghosh
 تاريخ النشر 2020
  مجال البحث فيزياء
والبحث باللغة English
 تأليف S. K. Ghosh




اسأل ChatGPT حول البحث

Performance of the Level-2 pipeline, which translates the UVIT data created by the ISROs ground segment processing systems (Level-1) into astronomer ready scientific data products, is described. This pipeline has evolved significantly from experiences during the in orbit mission. With time, the detector modules of UVIT developed certain defects which led to occasional corruption of imaging and timing data. This article will describe the improvements and mitigation plans incorporated in the pipeline and report its efficacy and quantify the performance.



قيم البحث

اقرأ أيضاً

We present the in-orbit performance and the first results from the ultra-violet Imaging telescope (UVIT) on ASTROSAT. UVIT consists of two identical 38cm coaligned telescopes, one for the FUV channel (130-180nm) and the other for the NUV (200-300nm) and VIS (320-550nm) channels, with a field of view of 28 $arcmin$. The FUV and the NUV detectors are operated in the high gain photon counting mode whereas the VIS detector is operated in the low gain integration mode. The FUV and NUV channels have filters and gratings, whereas the VIS channel has filters. The ASTROSAT was launched on 28th September 2015. The performance verification of UVIT was carried out after the opening of the UVIT doors on 30th November 2015, till the end of March 2016 within the allotted time of 50 days for calibration. All the on-board systems were found to be working satisfactorily. During the PV phase, the UVIT observed several calibration sources to characterise the instrument and a few objects to demonstrate the capability of the UVIT. The resolution of the UVIT was found to be about 1.4 - 1.7 $arcsec$ in the FUV and NUV. The sensitivity in various filters were calibrated using standard stars (white dwarfs), to estimate the zero-point magnitudes as well as the flux conversion factor. The gratings were also calibrated to estimate their resolution as well as effective area. The sensitivity of the filters were found to be reduced up to 15% with respect to the ground calibrations. The sensitivity variation is monitored on a monthly basis. UVIT is all set to roll out science results with its imaging capability with good resolution and large field of view, capability to sample the UV spectral region using different filters and capability to perform variability studies in the UV.
63 - S. K. Ghosh 2020
Over the last 5 years, UVIT has completed observations of more than 500 proposals with ~ 800 unique pointings. In addition, regular planned monitoring observations have been made and from their analysis various key parameters related to in orbit perf ormance of UVIT have been quantified. The sensitivities of the UV channels have remained steady indicating no effect of potential molecular contamination confirming the adequacy of all the protocols implemented for avoiding contamination. The quality of the PSF through the years confirms adequacy of thermal control measures. The early calibrations obtained during the Performance Verification (PV) phase have been further revised for more subtle effects. These include flat fields and detector distortions with greater precision. The operations of UVIT have also evolved through in orbit experience, e.g. tweaking of operational sequencing, protocol for recovery from bright object detection (BOD) shutdowns, parameters for BOD thresholds, etc. Finally, some effects of charged particle hits on electronics led to opimised strategy for regular resetting. The Near-UV channel was lost in one of such operations. All the above in-orbit experiences are presented here.
The performance of the ultraviolet telescope (UVIT) on-board ASTROSAT is reported. The performance in orbit is also compared with estimates made from the calibrations done on the ground. The sensitivity is found to be within ~15% of the estimates, an d the spatial resolution in the NUV is found to exceed significantly the design value of 1.8 arcsec and it is marginally better in the FUV. Images obtained from UVIT are presented to illustrate the details revealed by the high spatial resolution. The potential of multi-band observations in the ultraviolet with high spatial resolution is illustrated by some results.
112 - Song Huang 2017
The Subaru Strategic Program (SSP) is an ambitious multi-band survey using the Hyper Suprime-Cam (HSC) on the Subaru telescope. The Wide layer of the SSP is both wide and deep, reaching a detection limit of i~26.0 mag. At these depths, it is challeng ing to achieve accurate, unbiased, and consistent photometry across all five bands. The HSC data are reduced using a pipeline that builds on the prototype pipeline for the Large Synoptic Survey Telescope. We have developed a Python-based, flexible framework to inject synthetic galaxies into real HSC images called SynPipe. Here we explain the design and implementation of SynPipe and generate a sample of synthetic galaxies to examine the photometric performance of the HSC pipeline. For stars, we achieve 1% photometric precision at i~19.0 mag and 6% precision at i~25.0 in the i-band. For synthetic galaxies with single-Sersic profiles, forced CModel photometry achieves 13% photometric precision at i~20.0 mag and 18% precision at i~25.0 in the i-band. We show that both forced PSF and CModel photometry yield unbiased color estimates that are robust to seeing conditions. We identify several caveats that apply to the version of HSC pipeline used for the first public HSC data release (DR1) that need to be taking into consideration. First, the degree to which an object is blended with other objects impacts the overall photometric performance. This is especially true for point sources. Highly blended objects tend to have larger photometric uncertainties, systematically underestimated fluxes and slightly biased colors. Second, >20% of stars at 22.5< i < 25.0 mag can be misclassified as extended objects. Third, the current CModel algorithm tends to strongly underestimate the half-light radius and ellipticity of galaxy with i>21.5 mag.
172 - J.Postma 2011
We describe calibration data, and discuss performance of the photon-counting flight detectors for the Ultraviolet Imaging Telescopes on the Astrosat observatory. The paper describes dark current, flat field and light-spot images for FUV, NUV, and Vis ible band detectors at more than one wavelength setting for each. We also report on nominal gain and low-gain operations, full- and sub-window read rates, and non-photon-counting modes of operation, all expected to be used in flight. We derive corrections to the event centroids from the CMOS readout arrays, for different centroid algorithms. We derive spatial resolution values for each detector and plots of point-source signal saturation for different flux levels. We also discuss ways to correct for saturation in extended object images.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا