ترغب بنشر مسار تعليمي؟ اضغط هنا

A broadband X-ray spectral study of the Seyfert 1 galaxy ESO 141--G055 with XMM-Newton and NuSTAR

92   0   0.0 ( 0 )
 نشر من قبل Ritesh Ghosh
 تاريخ النشر 2020
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

We have extensively studied the broadband X-ray spectra of the source ESO~141--G055 using all available xmm{} and ustar{} observations. We detect a prominent soft excess below 2 keV, a narrow Fe line and a Compton hump (>10 keV). The origin of the soft excess is still debated. We used two models to describe the soft excess: the blurred reflection from the ionized accretion disk and the intrinsic thermal Comptonisation model. We find that both of these models explain the soft excess equally well. We confirm that we do not detect any broad Fe line in the X-ray spectra of this source, although both the physical models prefer a maximally spinning black hole scenario (a$>$0.96). This may mean that either the broad Fe line is absent or blurred beyond detection. The Eddington rate of the source is estimated to be $lambda_{Edd} sim 0.31$. In the reflection model, the Compton hump has a contribution from both ionized and neutral reflection components. The neutral reflector which simultaneously describes the narrow Fe K$alpha$ and the Compton hump has a column density of $rm N_{H} geq 7times 10^{24} rm cm^{-2} $. In addition, we detect a partially covering ionized absorption with ionization parameter $log xi/rm erg cm s^{-1}$ = $0.1^{+0.1}_{-0.1}$ and column density $rm N_{H} =20.6^{+1.0}_{-1.0}times 10^{22} rm cm^{-2}$ with a covering factor of $0.21^{+0.01}_{-0.01}$.



قيم البحث

اقرأ أيضاً

We present the results of NuSTAR and XMM-Newton observations of the two ultraluminous X-ray sources (ULX) NGC 1313 X-1 and X-2. The combined spectral bandpass of the two satellites enables us to produce the first spectrum of X-1 between 0.3 and 30 ke V, while X-2 is not significantly detected by NuSTAR above 10 keV. The NuSTAR data demonstrate that X-1 has a clear cutoff above 10 keV, whose presence was only marginally detectable with previous X-ray observations. This cutoff rules out the interpretation of X-1 as a black hole in a standard low/hard state, and it is deeper than predicted for the downturn of a broadened iron line in a reflection-dominated regime. The cutoff differs from the prediction of a single-temperature Comptonization model. Further, a cold disk-like black body component at ~0.3 keV is required by the data, confirming previous measurements by XMM-Newton only. We observe a spectral transition in X-2, from a state with high luminosity and strong variability to a lower-luminosity state with no detectable variability, and we link this behavior to a transition from a super-Eddington to a sub-Eddington regime.
103 - D. J. Walton , C. Pinto , M. Nowak 2019
We present results from the major coordinated X-ray observing program on the ULX NGC 1313 X-1 performed in 2017, combining $XMM$-$Newton$, $Chandra$ and $NuSTAR$, focusing on the evolution of the broadband ($sim$0.3-30.0 keV) continuum emission. Clea r and unusual spectral variability is observed, but this is markedly suppressed above $sim$10-15 keV, qualitatively similar to the ULX Holmberg IX X-1. We model the multi-epoch data with two-component accretion disc models designed to approximate super-Eddington accretion, allowing for both a black hole and a neutron star accretor. With regards to the hotter disc component, the data trace out two distinct tracks in the luminosity-temperature plane, with larger emitting radii and lower temperatures seen at higher observed fluxes. Despite this apparent anti-correlation, each of these tracks individually shows a positive luminosity-temperature relation. Both are broadly consistent with $Lpropto{T}^{4}$, as expected for blackbody emission with a constant area, and also with $Lpropto{T}^{2}$, as may be expected for an advection-dominated disc around a black hole. We consider a variety of possibilities for this unusual behaviour. Scenarios in which the innermost flow is suddenly blocked from view by outer regions of the super-Eddington disc/wind can explain the luminosity-temperature behaviour, but are difficult to reconcile with the lack of strong variability at higher energies, assuming this emission arises from the most compact regions. Instead, we may be seeing evidence for further radial stratification of the accretion flow than is included in the simple models considered, with a combination of winds and advection resulting in the suppressed high-energy variability.
We present the results from coordinated X-ray observations of the ultraluminous X-ray source NGC 5204 X-1 performed by NuSTAR and XMM-Newton in early 2013. These observations provide the first detection of NGC 5204 X-1 above 10 keV, extending the bro adband coverage to 0.3-20 keV. The observations were carried out in two epochs separated by approximately 10 days, and showed little spectral variation, with an observed luminosity of Lx = (4.95+/-0.11)e39 erg/s. The broadband spectrum confirms the presence of a clear spectral downturn above 10 keV seen in some previous observations. This cutoff is inconsistent with the standard low/hard state seen in Galactic black hole binaries, as would be expected from an intermediate mass black hole accreting at significantly sub-Eddington rates given the observed luminosity. The continuum is apparently dominated by two optically thick thermal-like components, potentially accompanied by a faint high energy tail. The broadband spectrum is likely associated with an accretion disk that differs from a standard Shakura & Sunyaev thin disk.
We present results for two Ultraluminous X-ray Sources (ULXs), IC 342 X-1 and IC 342 X-2, using two epochs of XMM-Newton and NuSTAR observations separated by $sim$7 days. We observe little spectral or flux variability above 1 keV between epochs, with unabsorbed 0.3--30 keV luminosities being $1.04^{+0.08}_{-0.06} times 10^{40}$ erg s$^{-1}$ for IC 342 X-1 and $7.40pm0.20 times 10^{39}$ erg s$^{-1}$ for IC 342 X-2, so that both were observed in a similar, luminous state. Both sources have a high absorbing column in excess of the Galactic value. Neither source has a spectrum consistent with a black hole binary in low/hard state, and both ULXs exhibit strong curvature in their broadband X-ray spectra. This curvature rules out models that invoke a simple reflection-dominated spectrum with a broadened iron line and no cutoff in the illuminating power-law continuum. X-ray spectrum of IC 342 X-1 can be characterized by a soft disk-like black body component at low energies and a cool, optically thick Comptonization continuum at high energies, but unique physical interpretation of the spectral components remains challenging. The broadband spectrum of IC 342 X-2 can be fit by either a hot (3.8 keV) accretion disk, or a Comptonized continuum with no indication of a seed photon population. Although the seed photon component may be masked by soft excess emission unlikely to be associated with the binary system, combined with the high absorption column, it is more plausible that the broadband X-ray emission arises from a simple thin blackbody disk component. Secure identification of the origin of the spectral components in these sources will likely require broadband spectral variability studies.
We discuss the broadband X-ray spectrum of GRS 1734-292 obtained from non-simultaneous XMM-Newton and NuSTAR observations, performed in 2009 and 2014, respectively. GRS1734-292 is a Seyfert 1 galaxy, located near the Galactic plane at $z=0.0214$. The NuSTAR spectrum ($3-80$ keV) is dominated by a primary power-law continuum with $Gamma=1.65 pm 0.05$ and a high-energy cutoff $E_c=53^{+11}_{-8}$ keV, one of the lowest measured by NuSTAR in a Seyfert galaxy. Comptonization models show a temperature of the coronal plasma of $kT_e=11.9^{+1.2}_{-0.9}$ keV and an optical depth, assuming a slab geometry, $tau=2.98^{+0.16}_{-0.19}$ or a similar temperature and $tau=6.7^{+0.3}_{-0.4}$ assuming a spherical geometry. The 2009 XMM-Newton spectrum is well described by a flatter intrinsic continuum ($Gamma=1.47^{+0.07}_{-0.03}$) and one absorption line due to Fetextsc{XXV} K$alpha$ produced by a warm absorber. Both data sets show a modest iron K$alpha$ emission line at $6.4$ keV and the associated Compton reflection, due to reprocessing from neutral circumnuclear material.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا